Cardiorespiratory noise correction improves the ASL signal.

Mahlega S Hassanpour1, Qingfei Luo1, W Kyle Simmons1,2, Justin S Feinstein1,2, Martin P Paulus1, Wen-Ming Luh3, Jerzy Bodurka1,4, Sahib S Khalsa1,2.   

Abstract

Cardiorespiratory fluctuations such as changes in heart rate or respiration volume influence the temporal dynamics of cerebral blood flow (CBF) measurements during arterial spin labeling (ASL) fMRI. This "physiological noise" can confound estimates of resting state network activity, and it may lower the signal-to-noise ratio of ASL during task-related experiments. In this study we examined several methods for minimizing the contributions of both synchronized and non-synchronized physiological noise in ASL measures of CBF, by combining the RETROICOR approach with different linear deconvolution models. We evaluated the amount of variance in CBF that could be explained by each method during physiological rest, in both resting state and task performance conditions. To further demonstrate the feasibility of this approach, we induced low-frequency cardiorespiratory deviations via peripheral adrenergic stimulation with isoproterenol, and determined how these fluctuations influenced CBF, before and after applying noise correction. By suppressing physiological noise, we observed substantial improvements in the signal-to-noise ratio at the individual and group activation levels. Our results suggest that variations in cardiac and respiratory parameters can account for a large proportion of the variance in resting and task-based CBF, and indicate that regressing out these non-neuronal signal variations improves the intrinsically low signal-to-noise ratio of ASL. This approach may help to better identify and control physiologically driven activations in ASL resting state and task-based analyses.
© 2018 Wiley Periodicals, Inc.

Entities:  

Keywords:  arterial spin labeling; cardiorespiratory stimulation; cerebral blood flow; non-synchronized noise; physiological noise reduction; synchronized noise

Mesh:

Substances:

Year:  2018        PMID: 29450932      PMCID: PMC5951743          DOI: 10.1002/hbm.24000

Source DB:  PubMed          Journal:  Hum Brain Mapp        ISSN: 1065-9471            Impact factor:   5.038


  61 in total

1.  Optimization of background suppression for arterial spin labeling perfusion imaging.

Authors:  Nasim Maleki; Weiying Dai; David C Alsop
Journal:  MAGMA       Date:  2011-10-19       Impact factor: 2.310

Review 2.  Dynamics of emotional effects on spatial attention in the human visual cortex.

Authors:  Gilles Pourtois; Patrik Vuilleumier
Journal:  Prog Brain Res       Date:  2006       Impact factor: 2.453

3.  Physiological noise reduction for arterial spin labeling functional MRI.

Authors:  Khaled Restom; Yashar Behzadi; Thomas T Liu
Journal:  Neuroimage       Date:  2006-03-13       Impact factor: 6.556

4.  The respiration response function: the temporal dynamics of fMRI signal fluctuations related to changes in respiration.

Authors:  Rasmus M Birn; Monica A Smith; Tyler B Jones; Peter A Bandettini
Journal:  Neuroimage       Date:  2007-12-15       Impact factor: 6.556

5.  Physiological modulations in arterial spin labeling perfusion magnetic resonance imaging.

Authors:  Wen-Chau Wu; Brian L Edlow; Mark A Elliot; Jiongjiong Wang; John A Detre
Journal:  IEEE Trans Med Imaging       Date:  2009-01-13       Impact factor: 10.048

6.  Subject specific BOLD fMRI respiratory and cardiac response functions obtained from global signal.

Authors:  Maryam Falahpour; Hazem Refai; Jerzy Bodurka
Journal:  Neuroimage       Date:  2013-01-31       Impact factor: 6.556

Review 7.  [Clinical applications of arterial spin labeling technique in brain diseases].

Authors:  Li Wang; Gang Zheng; Tiezhu Zhao; Chao Guo; Lin Li; Guangming Lu
Journal:  Sheng Wu Yi Xue Gong Cheng Xue Za Zhi       Date:  2013-02

8.  Dynamics of the cerebral blood flow response to step changes in end-tidal PCO2 and PO2 in humans.

Authors:  M J Poulin; P J Liang; P A Robbins
Journal:  J Appl Physiol (1985)       Date:  1996-09

9.  Isometric handgrip exercise during cardiovascular magnetic resonance imaging: set-up and cardiovascular effects.

Authors:  Florian von Knobelsdorff-Brenkenhoff; Matthias A Dieringer; Katharina Fuchs; Fabian Hezel; Thoralf Niendorf; Jeanette Schulz-Menger
Journal:  J Magn Reson Imaging       Date:  2013-01-24       Impact factor: 4.813

10.  Panic Anxiety in Humans with Bilateral Amygdala Lesions: Pharmacological Induction via Cardiorespiratory Interoceptive Pathways.

Authors:  Sahib S Khalsa; Justin S Feinstein; Wei Li; Jamie D Feusner; Ralph Adolphs; Rene Hurlemann
Journal:  J Neurosci       Date:  2016-03-23       Impact factor: 6.167

View more
  2 in total

1.  Cardiorespiratory noise correction improves the ASL signal.

Authors:  Mahlega S Hassanpour; Qingfei Luo; W Kyle Simmons; Justin S Feinstein; Martin P Paulus; Wen-Ming Luh; Jerzy Bodurka; Sahib S Khalsa
Journal:  Hum Brain Mapp       Date:  2018-02-15       Impact factor: 5.038

2.  Influence of the cardiac cycle on velocity selective and acceleration selective arterial spin labeling.

Authors:  Suzanne L Franklin; Sophie Schmid; Clemens Bos; Matthias J P van Osch
Journal:  Magn Reson Med       Date:  2019-09-04       Impact factor: 4.668

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.