Literature DB >> 29439015

Respiratory Motion Compensation for PET/CT with Motion Information Derived from Matched Attenuation-Corrected Gated PET Data.

Yihuan Lu1, Kathryn Fontaine2, Tim Mulnix2, John A Onofrey2, Silin Ren3, Vladimir Panin4, Judson Jones4, Michael E Casey4, Robert Barnett5, Peter Kench5, Roger Fulton5, Richard E Carson2,3, Chi Liu2,3.   

Abstract

Respiratory motion degrades the detection and quantification capabilities of PET/CT imaging. Moreover, mismatch between a fast helical CT image and a time-averaged PET image due to respiratory motion results in additional attenuation correction artifacts and inaccurate localization. Current motion compensation approaches typically have 3 limitations: the mismatch among respiration-gated PET images and the CT attenuation correction (CTAC) map can introduce artifacts in the gated PET reconstructions that can subsequently affect the accuracy of the motion estimation; sinogram-based correction approaches do not correct for intragate motion due to intracycle and intercycle breathing variations; and the mismatch between the PET motion compensation reference gate and the CT image can cause an additional CT-mismatch artifact. In this study, we established a motion correction framework to address these limitations.
Methods: In the proposed framework, the combined emission-transmission reconstruction algorithm was used for phase-matched gated PET reconstructions to facilitate the motion model building. An event-by-event nonrigid respiratory motion compensation method with correlations between internal organ motion and external respiratory signals was used to correct both intracycle and intercycle breathing variations. The PET reference gate was automatically determined by a newly proposed CT-matching algorithm. We applied the new framework to 13 human datasets with 3 different radiotracers and 323 lesions and compared its performance with CTAC and non-attenuation correction (NAC) approaches. Validation using 4-dimensional CT was performed for one lung cancer dataset.
Results: For the 10 18F-FDG studies, the proposed method outperformed (P < 0.006) both the CTAC and the NAC methods in terms of region-of-interest-based SUVmean, SUVmax, and SUV ratio improvements over no motion correction (SUVmean: 19.9% vs. 14.0% vs. 13.2%; SUVmax: 15.5% vs. 10.8% vs. 10.6%; SUV ratio: 24.1% vs. 17.6% vs. 16.2%, for the proposed, CTAC, and NAC methods, respectively). The proposed method increased SUV ratios over no motion correction for 94.4% of lesions, compared with 84.8% and 86.4% using the CTAC and NAC methods, respectively. For the 2 18F-fluoropropyl-(+)-dihydrotetrabenazine studies, the proposed method reduced the CT-mismatch artifacts in the lower lung where the CTAC approach failed and maintained the quantification accuracy of bone marrow where the NAC approach failed. For the 18F-FMISO study, the proposed method outperformed both the CTAC and the NAC methods in terms of motion estimation accuracy at 2 lung lesion locations.
Conclusion: The proposed PET/CT respiratory event-by-event motion-correction framework with motion information derived from matched attenuation-corrected PET data provides image quality superior to that of the CTAC and NAC methods for multiple tracers.
© 2018 by the Society of Nuclear Medicine and Molecular Imaging.

Entities:  

Keywords:  PET; event-by-event; matched attenuation correction; non-rigid; respiratory motion correction

Mesh:

Year:  2018        PMID: 29439015      PMCID: PMC6126443          DOI: 10.2967/jnumed.117.203000

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  18 in total

1.  Nonrigid registration using free-form deformations: application to breast MR images.

Authors:  D Rueckert; L I Sonoda; C Hayes; D L Hill; M O Leach; D J Hawkes
Journal:  IEEE Trans Med Imaging       Date:  1999-08       Impact factor: 10.048

2.  Respiration-induced attenuation artifact at PET/CT: technical considerations.

Authors:  Gerhard W Goerres; Cyrill Burger; Ehab Kamel; Burkhardt Seifert; Achim H Kaim; Alfred Buck; Tobias C Buehler; Gustav K Von Schulthess
Journal:  Radiology       Date:  2003-03       Impact factor: 11.105

3.  Clinically significant inaccurate localization of lesions with PET/CT: frequency in 300 patients.

Authors:  Medhat M Osman; Christian Cohade; Yuji Nakamoto; Laura T Marshall; Jeff P Leal; Richard L Wahl
Journal:  J Nucl Med       Date:  2003-02       Impact factor: 10.057

Review 4.  PET of hypoxia: current and future perspectives.

Authors:  Sean Carlin; John L Humm
Journal:  J Nucl Med       Date:  2012-07-12       Impact factor: 10.057

5.  Simultaneous reconstruction of activity and attenuation in time-of-flight PET.

Authors:  Ahmadreza Rezaei; Michel Defrise; Girish Bal; Christian Michel; Maurizio Conti; Charles Watson; Johan Nuyts
Journal:  IEEE Trans Med Imaging       Date:  2012-08-09       Impact factor: 10.048

6.  Respiratory motion blur identification and reduction in ungated thoracic PET imaging.

Authors:  Quansheng Xu; Kehong Yuan; Datian Ye
Journal:  Phys Med Biol       Date:  2011-06-30       Impact factor: 3.609

7.  Generation of 4-dimensional CT images based on 4-dimensional PET-derived motion fields.

Authors:  Hadi J Fayad; Frederic Lamare; Catherine Cheze Le Rest; Valentino Bettinardi; Dimitris Visvikis
Journal:  J Nucl Med       Date:  2013-03-07       Impact factor: 10.057

8.  Unified framework for development, deployment and robust testing of neuroimaging algorithms.

Authors:  Alark Joshi; Dustin Scheinost; Hirohito Okuda; Dominique Belhachemi; Isabella Murphy; Lawrence H Staib; Xenophon Papademetris
Journal:  Neuroinformatics       Date:  2011-03

9.  In vivo imaging of endogenous pancreatic β-cell mass in healthy and type 1 diabetic subjects using 18F-fluoropropyl-dihydrotetrabenazine and PET.

Authors:  Marc D Normandin; Kitt F Petersen; Yu-Shin Ding; Shu-Fei Lin; Sarita Naik; Krista Fowles; Daniel M Skovronsky; Kevan C Herold; Timothy J McCarthy; Roberto A Calle; Richard E Carson; Judith L Treadway; Gary W Cline
Journal:  J Nucl Med       Date:  2012-05-09       Impact factor: 10.057

10.  List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations.

Authors:  F Lamare; M J Ledesma Carbayo; T Cresson; G Kontaxakis; A Santos; C Cheze Le Rest; A J Reader; D Visvikis
Journal:  Phys Med Biol       Date:  2007-08-09       Impact factor: 3.609

View more
  12 in total

1.  Total Body PET: Why, How, What for?

Authors:  Suleman Surti; Austin R Pantel; Joel S Karp
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2020-04-03

2.  Deep Learning Based Joint PET Image Reconstruction and Motion Estimation.

Authors:  Tiantian Li; Mengxi Zhang; Wenyuan Qi; Evren Asma; Jinyi Qi
Journal:  IEEE Trans Med Imaging       Date:  2022-05-02       Impact factor: 11.037

3.  Motion correction of respiratory-gated PET images using deep learning based image registration framework.

Authors:  Tiantian Li; Mengxi Zhang; Wenyuan Qi; Evren Asma; Jinyi Qi
Journal:  Phys Med Biol       Date:  2020-07-30       Impact factor: 3.609

4.  Direct List Mode Parametric Reconstruction for Dynamic Cardiac SPECT.

Authors:  Luyao Shi; Yihuan Lu; Jing Wu; Jean-Dominique Gallezot; Nabil Boutagy; Stephanie Thorn; Albert J Sinusas; Richard E Carson; Chi Liu
Journal:  IEEE Trans Med Imaging       Date:  2019-06-10       Impact factor: 10.048

5.  New Data-Driven Gated PET/CT Free of Misregistration Artifacts.

Authors:  Tinsu Pan; Yang Lu; M Allan Thomas; Zhongxing Liao; Dershan Luo
Journal:  Int J Radiat Oncol Biol Phys       Date:  2020-11-10       Impact factor: 7.038

6.  Clinical and scientific value in the pursuit of quantification of beta cells in the pancreas by PET imaging.

Authors:  Gary W Cline; Timothy J McCarthy; Richard E Carson; Roberto A Calle
Journal:  Diabetologia       Date:  2018-08-22       Impact factor: 10.460

7.  Deep learning-based attenuation correction for whole-body PET - a multi-tracer study with 18F-FDG, 68 Ga-DOTATATE, and 18F-Fluciclovine.

Authors:  Takuya Toyonaga; Dan Shao; Luyao Shi; Jiazhen Zhang; Enette Mae Revilla; David Menard; Joseph Ankrah; Kenji Hirata; Ming-Kai Chen; John A Onofrey; Yihuan Lu
Journal:  Eur J Nucl Med Mol Imaging       Date:  2022-03-12       Impact factor: 10.057

8.  Data-driven gated CT: An automated respiratory gating method to enable data-driven gated PET/CT.

Authors:  Tinsu Pan; M Allan Thomas; Dershan Luo
Journal:  Med Phys       Date:  2022-04-22       Impact factor: 4.506

9.  Radiomics model of dual-time 2-[18F]FDG PET/CT imaging to distinguish between pancreatic ductal adenocarcinoma and autoimmune pancreatitis.

Authors:  Zhaobang Liu; Ming Li; Changjing Zuo; Zehong Yang; Xiaokai Yang; Shengnan Ren; Ye Peng; Gaofeng Sun; Jun Shen; Chao Cheng; Xiaodong Yang
Journal:  Eur Radiol       Date:  2021-03-06       Impact factor: 5.315

10.  Automatic Inter-Frame Patient Motion Correction for Dynamic Cardiac PET Using Deep Learning.

Authors:  Luyao Shi; Yihuan Lu; Nicha Dvornek; Christopher A Weyman; Edward J Miller; Albert J Sinusas; Chi Liu
Journal:  IEEE Trans Med Imaging       Date:  2021-11-30       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.