Literature DB >> 29427201

Use of fully threaded cannulated screws decreases femoral neck shortening after fixation of femoral neck fractures.

Yoram A Weil1, Feras Qawasmi2, Meir Liebergall2, Rami Mosheiff2, Amal Khoury2.   

Abstract

BACKGROUND: Femoral neck fractures (FNF) are becoming increasingly common as population ages. Nondisplaced fractures are commonly treated by cancellous, parallel placed, partially threaded cannulated screws (PTS). This allows controlled fracture impaction. However, sliding implants can lead to femoral neck shortening (FNS) that has been shown to be correlated with reduced quality of life and impaired gait pattern. Recently, in our institution we have changed the fixation of FNF to fully threaded screws (FTS) with or without an additional partially threaded screw in order to minimize this phenomenon. The aim of this study was to compare the FNS in patients treated with FTS as compared with our historical controls treated with PTS. PATIENTS AND METHODS: Between 2014 and 2016, 38 patients with FNF were treated with FTS. Out of the 38, 24 were available for radiographic follow-up. 41 patients treated previously with PTS were available as a control group. Radiographic analysis was performed to assess the FNF in three vectors: Horizontal (X), Vertical (Y) and overall (Z) according to the neck-shaft angle.
RESULTS: Time for admission to surgery was longer in the PTS group (p = 0.04). Patient demographics and major complication rates were similar in the two patient groups. Average FNS in the X axis was significantly smaller in the FTS group than in the PTS group (2.8 ± 3.6 vs 7.6 ± 4.2 mm, p < 0.01) as well as the Y axis (1.2 ± 2.6 vs 4.9 ± 4.2 mm, p < 0.01) and thus also decreased overall Z shortening (2.3 ± 3.5 vs 6.23 ± 4.5 mm, p < 0.01). There was a tendency towards a more valgus reduction in the PTS (137° vs 134°, p = 0.08). There was a significantly smaller number of FTS patients with moderate (5-10 mm) or severe (> 10 mm) FNS. Screw pull-out > 5 mm occurred in 17/41 patients in the PTS but none in the FTS group (p < 0.01).
CONCLUSION: This study proves that use of FTS improves the radiographic results following FNF fixation using cannulated screws.

Entities:  

Keywords:  Femoral fractures; Fully threaded screws; Hip fractures

Mesh:

Year:  2018        PMID: 29427201     DOI: 10.1007/s00402-018-2896-y

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  15 in total

1.  Factors Associated with Femoral Neck Shortening After Closed or Open Reduction and Screw Fixation.

Authors:  Abdulkadir Polat; Abdulhamit Misir; Mehmet Ozbey Buyukkuscu; Seckin Basilgan; Hakan Basar
Journal:  Indian J Orthop       Date:  2021-08-14       Impact factor: 1.033

2.  [Short-term effectiveness of femoral neck system in the treatment of femoral neck fracture].

Authors:  Yajun Yang; Tao Ma; Xiaoyu Zhang; Xiaojun Luo; Tao Fan; Yuhai Wang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-05-15

3.  Biomechanical Evaluation of the Modified Cannulated Screws Fixation of Unstable Femoral Neck Fracture with Comminuted Posteromedial Cortex.

Authors:  Jingwen Liu; Baokun Zhang; Bohao Yin; Hongchi Chen; Hui Sun; Wei Zhang
Journal:  Biomed Res Int       Date:  2019-07-07       Impact factor: 3.411

4.  Influence of the proximal screws of buttress plates on the stability of vertical femoral neck fractures: a finite element analysis.

Authors:  Shi Zhan; Dajun Jiang; Jian Xu; Ming Ling; Kai Yang; Yuehua Li; Weitao Jia; Hai Hu; Changqing Zhang
Journal:  BMC Musculoskelet Disord       Date:  2020-12-12       Impact factor: 2.362

5.  Nonanatomical Reduction of Femoral Neck Fractures in Young Patients (≤65 Years Old) with Internal Fixation Using Three Parallel Cannulated Screws.

Authors:  Guanglei Zhao; Changquan Liu; Kangming Chen; Jinyang Lyu; Jie Chen; Jingsheng Shi; Feiyan Chen; Yibing Wei; Siqun Wang; Jun Xia; Gangyong Huang
Journal:  Biomed Res Int       Date:  2021-01-04       Impact factor: 3.411

6.  Comparison of Ordinary Cannulated Compression Screw and Double-Head Cannulated Compression Screw Fixation in Vertical Femoral Neck Fractures.

Authors:  Yuelei Zhang; Chao Yan; Lecheng Zhang; Wei Zhang; Gang Wang
Journal:  Biomed Res Int       Date:  2020-12-30       Impact factor: 3.411

7.  Decreased complications but a distinctive fixation loosening mechanism of fully threaded headless cannulated screw fixation for femoral neck fractures in young adults.

Authors:  Hui Sun; Lin-Yuan Shu; Matthew C Sherrier; Yi Zhu; Jing-Wen Liu; Wei Zhang
Journal:  J Orthop Surg Res       Date:  2021-03-30       Impact factor: 2.359

8.  Reversed Z-effect and Z-effect phenomena in femoral neck fracture treated with a dynamic locking plate fixation: Case report.

Authors:  Radoslav Morochovič; Miloš Kňazovický; Martin Paulo; Katarína Takáčová; Rastislav Burda
Journal:  Jt Dis Relat Surg       Date:  2020-09-11

9.  Finite element analysis of different configurations of fully threaded cannulated screw in the treatment of unstable femoral neck fractures.

Authors:  Jiantao Li; Menglin Wang; Lianting Li; Hao Zhang; Ming Hao; Chen Li; Lin Han; Jianfeng Zhou; Kun Wang
Journal:  J Orthop Surg Res       Date:  2018-10-29       Impact factor: 2.359

10.  Analysis on risk factors for neck shortening after internal fixation for Pauwels II femoral neck fracture in young patients.

Authors:  Fulong Zhao; Lijuan Guo; Xuefei Wang; Yakui Zhang
Journal:  Eur J Med Res       Date:  2021-06-24       Impact factor: 2.175

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.