What wrist should you wear your actigraphy device on? Analysis of dominant vs. non-dominant wrist actigraphy for measuring sleep in healthy adults.

Matthew William Driller1, Shannon O'Donnell1, Francisco Tavares1.   

Abstract

OBJECTIVE: Differences in sleep results due to the placement of actigraphy devices (non-dominant vs. dominant wrist) are yet to be determined.
METHODS: 65 nights of data from 13 adult participants was collected while participants wore two actigraphy devices, one on each wrist. Sleep indices including total sleep time (TST), total time in bed (TTB), sleep efficiency (SE%), sleep latency (SL), wake after sleep onset (WASO), sleep onset time (SOT) and wake time (WT) were assessed between the two devices.
RESULTS: There were no significant differences between devices for any of the measured sleep variables (p>0.05). SE%, SL and WASO resulted in high correlations between devices (0.89, 0.89 and 0.76, respectively), with all other sleep variables resulting in very high correlations (>0.90) between devices.
CONCLUSIONS: Based on our results, it does not seem critical which wrist the actigraphy device is worn on for measuring key sleep variables.

Entities:  

Keywords:  Actigraphy; Polysomnography; Technology; Validity of Tests

Year:  2017        PMID: 29410743      PMCID: PMC5699857          DOI: 10.5935/1984-0063.20170023

Source DB:  PubMed          Journal:  Sleep Sci        ISSN: 1984-0063


INTRODUCTION

The quantification and measurement of sleep amongst various interventional and population research studies and clinical settings is of increasing importance. Sleep monitoring has also become a substantial consumer industry, with a rising rate of commercial companies producing various wearable sleep monitoring devices[1]. Although considered the 'gold standard' method of sleep measurement, polysomnography (PSG) requires a somewhat intrusive and expensive assessment of sleep indices. Wrist actigraphy is a non-intrusive, cost-effective tool used to estimate sleep quantity and quality which has been compared to PSG, showing an accuracy of up to 93% in healthy adults for total sleep time and sleep efficiency[2,3] and as such is widely used in the sleep literature[4]. Actigraphy involves the use of a device housed in a wristwatch that contains a small accelerometer capable of sensing movement along any one of three axes[4]. The accelerometer is sampled multiple times per second and the actigraph is downloaded and either manually or automatically scored for sleep indices. While actigraphy has become commonplace in both the research and consumer setting, the optimal placement of the actigraph itself is relatively unknown. Traditionally, the majority of research studies recommend that the actigraphy device should be worn on the non-dominant wrist[4], however some studies have suggested that it may be more suitable to wear the actigraph on the dominant wrist[5], and others do not specify what wrist it should be worn on[6]. Furthermore, the new emerging technology over the past decade has seen improved automatic scoring actigraphy devices, reducing the need for sleep technicians. Given the increasing use of actigraphy for monitoring sleep, the new and emerging technology for automatic scoring of devices and the disparate recommendations in the literature, this is an important area that needs further clarification. Therefore, the aim of the current case study was to determine if differences exist between wearing automatic-scoring actigraphy devices on the non-dominant and dominant wrists in healthy adults.

METHODS

Participants

A total of 13 healthy adults (8 male / 5 female, mean ± SD, age: 26±7) volunteered to take part in the study. All participants were free of any diagnosed sleep disorders. Ethical approval for the study was obtained through the institutions Human Research Ethics Committee.

Study Design

Participants were required to wear a wrist actigraphy device (Readiband, Fatigue Science, Vancouver) on each wrist (dominant and non-dominant) over a period of 5 nights. Participants were instructed to maintain their usual sleep habits and general daily activity patterns during the monitoring period, and were instructed to leave the devices on at all times. The Readiband has been validated against PSG, with accuracy levels of 93% being reported[7] and research from our laboratory has also shown that the Readiband results in acceptable levels of inter-device reliability (ICC = >0.90)[8]. At the conclusion of each recording period, actigraphy data were wirelessly downloaded to a computer using a Nordic 2.4 GHz ANT transceiver, which was then analysed using Fatigue Science software (16Hz sampling rate: ReadibandT, Fatigue Science, Vancouver). The raw activity scores were translated to sleep-wake scores based on computerized scoring algorithms. Sleep indices including total sleep time (TST), sleep efficiency (SE%), total time in bed (TTB), sleep latency (SL), wake after sleep onset (WASO), sleep onset time (SOT) and wake time (WT) were used for comparison between devices.

Statistical Analysis

Simple group statistics are shown as means ± standard deviations unless stated otherwise. An independent-samples T-test was used to compare dominant and non-dominant wrist measures using the Statistical Package for Social Science (V. 22.0, SPSS Inc., Chicago, IL), with statistical significance set at p<0.05. Inter-device agreements for dominant and non-dominant wrists were examined using Pearson's correlation coefficients (r) with 95% confidence intervals (95% CI) and interpreted as 0.90-1.00 = very high correlation, 0.70-0.89 = high correlation, 0.50-0.69 = moderate correlation, 0.26-0.49 = low correlation and 0.00-0.25 = little, if any correlation[9]. Between-device typical error of estimates (TEE) was determined using an excel spreadsheet[10] and are presented as a coefficient of variation percentage (CV%) and as absolute values. Similar to Werner et al.[11], we defined an apriori difference between the 2 devices of = 30 min satisfactory for TST, with a difference < 5% for SE satisfactory.

RESULTS

There were no significant differences between devices for any of the measured sleep variables (p>0.05). Mean differences of 6 mins and 2 min between non-dominant and dominant wrists for TST and TTB were associated with CV% scores of 4.6 and 3.8%, respectively (Table 1).
Table 1

Mean ± SD values for the measured sleep variables between non-dominant and dominant wrist-actigraphy devices. Comparison between devices are reported using mean bias, Pearson correlations (r), typical error of estimates (TEE) and coefficient of variation % with 95% confidence intervals.

 Non-DominantDominantMean biasPearson's rTEECV%
Total Sleep Time (mins)436±72442±806±190.97 (0.95 - 0.98)18 (15 -22)4.6 (3.8 - 4.7)
Total Time in Bed (mins)552±85554±832±200.97 (0.95 - 0.98)20 (17 - 25)3.8 (3.1 - 4.7)
Sleep Efficiency (%)81±982±61±40.89 (0.81 - 0.94)4 (3 - 5)5.3 (4.4 - 6.6)
Sleep Latency (mins)29±3428±31-1±150.89 (0.82 - 0.94)15 (13 - 19)102.4 (80.2 - 140.7)
Wake After Sleep Onset (mins)53±3852±43-1±280.76 (0.61 - 0.86)25 (21 - 32)60.5 (47.7 - 82.5)
Sleep Onset Time (time of day)23:25±1:3223:24±1:33-1±110.99 (0.99 - 0.99)12 (11 - 15)0.8 (0.7 - 1.0)
Wake Time (time of day)7:30±1:217:31±1:211±111.00 (1.00 - 1.00)11 (9 - 14)2.5 (2.1 - 3.1)
Mean ± SD values for the measured sleep variables between non-dominant and dominant wrist-actigraphy devices. Comparison between devices are reported using mean bias, Pearson correlations (r), typical error of estimates (TEE) and coefficient of variation % with 95% confidence intervals. TST, TTB, SOT and WT all resulted in very high correlations (>0.90), with SE%, SL and WASO resulting in high correlations between devices (0.89, 0.89 and 0.76, respectively).

DISCUSSION

The main finding in the current study was that there were no significant differences between non-dominant and dominant wrist actigraphy for monitoring sleep in healthy adults. The non-significant differences between devices were associated with high to very high correlations for all sleep measures and relatively low (~5%) CV's for the key sleep variables of total sleep time, total time in bed and sleep efficiency. The typical error of estimate for total sleep time and total time in bed was ~20 minutes and the mean bias was ~5 minutes, suggesting that there is little difference in what wrist the actigraph is worn on. Correlation plots between non-dominant and dominant wrist actigraphy data for: a) total sleep time (mins), and b) sleep efficiency (%). The use of wrist-actigraphy for monitoring sleep is becoming increasingly popular in numerous research fields, including athletic[12], clinical[13], adolescent[14] and pediatric[15] populations. However, while traditionally it was suggested that actigraphy devices should be worn on the dominant wrist of participants[16], there is a lack of evidence to show whether or not any differences actually exist. Furthermore, the ever-evolving technology of sleep monitoring via actigraphy has introduced automatic-scoring devices[8], further identifying the need to investigate differences in the placement of devices. As previously suggested[6,17], care should be taken when interpreting results for WASO and SL when measured via wrist actigraphy, as the accuracy of these measures when compared to PSG is questionable. The current study would support this, as these were the most variable sleep indices between the two devices, with typical error of estimates and CV% of ~25 minutes and ~60% for WASO and ~15 minutes and ~100% for SL, respectively. Results from the current study would suggest that the placement of the actigraphy device (dominant vs. non-dominant wrist) is not critical for accurate sleep measurement of key sleep measures including total sleep time, total time in bed, sleep onset and wake time. Given this, the authors would recommend that individuals wearing actigraphy devices, either as general consumers or research participants, should opt to wear their actigraphy device on whatever wrist feels the most comfortable. Indeed, if the device feels uncomfortable, it is more likely to influence adherence to wearing the monitor and overall sleep results.
  13 in total

1.  Measuring sleep: accuracy, sensitivity, and specificity of wrist actigraphy compared to polysomnography.

Authors:  Miguel Marino; Yi Li; Michael N Rueschman; J W Winkelman; J M Ellenbogen; J M Solet; Hilary Dulin; Lisa F Berkman; Orfeu M Buxton
Journal:  Sleep       Date:  2013-11-01       Impact factor: 5.849

Review 2.  The role and validity of actigraphy in sleep medicine: an update.

Authors:  Avi Sadeh
Journal:  Sleep Med Rev       Date:  2011-01-14       Impact factor: 11.609

Review 3.  Consumer Sleep Technologies: A Review of the Landscape.

Authors:  Ping-Ru T Ko; Julie A Kientz; Eun Kyoung Choe; Matthew Kay; Carol A Landis; Nathaniel F Watson
Journal:  J Clin Sleep Med       Date:  2015-12-15       Impact factor: 4.062

4.  Agreement of different methods for assessing sleep characteristics: a comparison of two actigraphs, wrist and hip placement, and self-report with polysomnography.

Authors:  Melanie Zinkhan; Klaus Berger; Sabrina Hense; Maren Nagel; Anne Obst; Beate Koch; Thomas Penzel; Ingo Fietze; Wolfgang Ahrens; Peter Young; Svenja Happe; Jan W Kantelhardt; Alexander Kluttig; Andrea Schmidt-Pokrzywniak; Frank Pillmann; Andreas Stang
Journal:  Sleep Med       Date:  2014-05-28       Impact factor: 3.492

5.  Activity-based sleep-wake identification: an empirical test of methodological issues.

Authors:  A Sadeh; K M Sharkey; M A Carskadon
Journal:  Sleep       Date:  1994-04       Impact factor: 5.849

6.  Assessment of physical activity and sleep by actigraphy: examination of gender differences.

Authors:  G Jean-Louis; M V Mendlowicz; H Von Gizycki; F Zizi; J Nunes
Journal:  J Womens Health Gend Based Med       Date:  1999-10

7.  Comparison of actigraphic, polysomnographic, and subjective assessment of sleep parameters in sleep-disordered patients.

Authors:  C A Kushida; A Chang; C Gadkary; C Guilleminault; O Carrillo; W C Dement
Journal:  Sleep Med       Date:  2001-09       Impact factor: 3.492

8.  Comparison of 7 versus 14 days wrist actigraphy monitoring in a sleep disorders clinic population.

Authors:  Samantha Briscoe; Emma Hardy; Martino F Pengo; Christopher Kosky; Adrian J Williams; Nicholas Hart; Joerg Steier
Journal:  Chronobiol Int       Date:  2013-12-04       Impact factor: 2.877

9.  Inter-device reliability of an automatic-scoring actigraph for measuring sleep in healthy adults.

Authors:  Matthew Driller; Joseph McQuillan; Shannon O'Donnell
Journal:  Sleep Sci       Date:  2016-08-24

10.  Sleep-hygiene Education improves Sleep Indices in Elite Female Athletes.

Authors:  Shannon O'Donnell; Matthew W Driller
Journal:  Int J Exerc Sci       Date:  2017-07-01
View more
  7 in total

1.  Detecting sleep using heart rate and motion data from multisensor consumer-grade wearables, relative to wrist actigraphy and polysomnography.

Authors:  Daniel M Roberts; Margeaux M Schade; Gina M Mathew; Daniel Gartenberg; Orfeu M Buxton
Journal:  Sleep       Date:  2020-07-13       Impact factor: 5.849

2.  Comparative Analysis of Physical Activity Detected via an External Accelerometer and Cardiac Implantable Electronic Devices.

Authors:  Chun-Kai Chen; Li-Ying Cheng; Shan-Wei Hsu; Min-Tsun Liao; Po-Wen Ku; Yen-Bin Liu
Journal:  Front Cardiovasc Med       Date:  2022-05-27

3.  Sleep and Performance during a Preseason in Elite Rugby Union Athletes.

Authors:  Angus R Teece; Christos K Argus; Nicholas Gill; Martyn Beaven; Ian C Dunican; Matthew W Driller
Journal:  Int J Environ Res Public Health       Date:  2021-04-27       Impact factor: 3.390

4.  Performance of Fitbit Charge 3 against polysomnography in measuring sleep in adolescent boys and girls.

Authors:  Luca Menghini; Dilara Yuksel; Aimee Goldstone; Fiona C Baker; Massimiliano de Zambotti
Journal:  Chronobiol Int       Date:  2021-04-01       Impact factor: 3.749

Review 5.  From pillow to podium: a review on understanding sleep for elite athletes.

Authors:  Shannon O'Donnell; Christopher M Beaven; Matthew W Driller
Journal:  Nat Sci Sleep       Date:  2018-08-24

6.  Hunger hormone and sleep responses to the built-in blue-light filter on an electronic device: a pilot study.

Authors:  Matthew William Driller; Gregory Jacobson; Liis Uiga
Journal:  Sleep Sci       Date:  2019 Jul-Sep

7.  Accelerometry-assessed sleep duration and timing in late childhood and adolescence in Scottish schoolchildren: A feasibility study.

Authors:  Laura M Lyall; Natasha Sangha; Cathy Wyse; Elaine Hindle; Dawn Haughton; Kate Campbell; Judith Brown; Laurence Moore; Sharon A Simpson; Joanna C Inchley; Daniel J Smith
Journal:  PLoS One       Date:  2020-12-01       Impact factor: 3.752

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.