Assessment of changes in blood glucose concentration with intravascular microdialysis.

Marc-Olivier Fischer1, Corentin Gouëzel2, Sabine Fradin3, Vladimir Saplacan4, Jean-Louis Gérard2, Jean-Luc Fellahi5,6, Jean-Luc Hanouz2.   

Abstract

Blood glucose and its variability of is a major prognostic factor associated with morbidity. We hypothesized that intravenous microdialysis incorporated in a central venous catheter (CVC) would be interchangeable with changes in blood glucose measured by the reference method using a blood gas analyzer. Microdialysis and central venous blood glucose measurements were simultaneously recorded in high-risk cardiac surgical patients. The correlation between absolute values was determined by linear regression and the Bland-Altman test for repeated measurements was used to compare bias, precision, and limits of agreement. Changes in blood glucose measurement were evaluated by four-quadrant plot and trend interchangeability methods (TIM). In the 23 patients analyzed, the CVC was used as part of standard care with no complications. The correlation coefficient for absolute values (N = 99) was R = 0.91 (P < 0.001). The bias, precision and limits of agreement were - 9.1, 17.4 and - 43.2 to 24.9 mg/dL, respectively. The concordance rate for changes in blood glucose measurements (N = 77) was 85% with the four-quadrant plot. The TIM showed that 14 (18%) changes of blood glucose measurements were uninterpretable. Among the remaining 63 (82%) interpretable changes, 23 (37%) were interchangeable, 13 (20%) were in the gray zone, and 27 (43%) were not interchangeable. Microdialysis using a CVC appears to provide imprecise absolute blood glucose values with risk of insulin misuse. Moreover, only one third of changes in blood glucose measurements were interchangeable with the reference method using the TIM.

Entities:  

Keywords:  Blood glucose; Cardiac surgery; Microdialysis; Monitoring; Trends

Mesh:

Substances:

Year:  2018        PMID: 29404891     DOI: 10.1007/s10877-018-0111-x

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  28 in total

1.  Risk factors and outcome in European cardiac surgery: analysis of the EuroSCORE multinational database of 19030 patients.

Authors:  F Roques; S A Nashef; P Michel; E Gauducheau; C de Vincentiis; E Baudet; J Cortina; M David; A Faichney; F Gabrielle; E Gams; A Harjula; M T Jones; P P Pintor; R Salamon; L Thulin
Journal:  Eur J Cardiothorac Surg       Date:  1999-06       Impact factor: 4.191

2.  Comparison of arterial and mixed venous blood glucose levels in hemodynamically unstable pigs: implications for location of a continuous glucose sensor.

Authors:  Nils K Skjaervold; Petter Aadahl
Journal:  Acta Diabetol       Date:  2012-04-17       Impact factor: 4.280

3.  Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed.

Authors:  Jan Kottner; Laurent Audigé; Stig Brorson; Allan Donner; Byron J Gajewski; Asbjørn Hróbjartsson; Chris Roberts; Mohamed Shoukri; David L Streiner
Journal:  J Clin Epidemiol       Date:  2010-06-17       Impact factor: 6.437

Review 4.  Why Have So Many Intravascular Glucose Monitoring Devices Failed?

Authors:  John L Smith; Mark J Rice
Journal:  J Diabetes Sci Technol       Date:  2015-07

5.  The surveillance error grid.

Authors:  David C Klonoff; Courtney Lias; Robert Vigersky; William Clarke; Joan Lee Parkes; David B Sacks; M Sue Kirkman; Boris Kovatchev
Journal:  J Diabetes Sci Technol       Date:  2014-06-13

6.  Evaluation of a continuous blood glucose monitoring system using central venous microdialysis.

Authors:  Fanny Schierenbeck; Anders Franco-Cereceda; Jan Liska
Journal:  J Diabetes Sci Technol       Date:  2012-11-01

7.  The evaluation of the ability of closed-loop glycemic control device to maintain the blood glucose concentration in intensive care unit patients.

Authors:  Tomoaki Yatabe; Rie Yamazaki; Hiroyuki Kitagawa; Takehiro Okabayashi; Koichi Yamashita; Kazuhiro Hanazaki; Masataka Yokoyama
Journal:  Crit Care Med       Date:  2011-03       Impact factor: 7.598

8.  Poor intraoperative blood glucose control is associated with a worsened hospital outcome after cardiac surgery in diabetic patients.

Authors:  Alexandre Ouattara; Patrick Lecomte; Yannick Le Manach; Marc Landi; Sophie Jacqueminet; Igor Platonov; Nicolas Bonnet; Bruno Riou; Pierre Coriat
Journal:  Anesthesiology       Date:  2005-10       Impact factor: 7.892

9.  Accuracy, reliability, feasibility and nurse acceptance of a subcutaneous continuous glucose management system in critically ill patients: a prospective clinical trial.

Authors:  Tobias Wollersheim; Lilian Jo Engelhardt; Jeanne Pachulla; Rudolf Moergeli; Susanne Koch; Claudia Spies; Michael Hiesmayr; Steffen Weber-Carstens
Journal:  Ann Intensive Care       Date:  2016-07-21       Impact factor: 6.925

Review 10.  Continuous glucose monitoring in the ICU: clinical considerations and consensus.

Authors:  James S Krinsley; J Geoffrey Chase; Jan Gunst; Johan Martensson; Marcus J Schultz; Fabio S Taccone; Jan Wernerman; Julien Bohe; Christophe De Block; Thomas Desaive; Pierre Kalfon; Jean-Charles Preiser
Journal:  Crit Care       Date:  2017-07-31       Impact factor: 9.097

View more
  1 in total

1.  Accuracy and stability of an arterial sensor for glucose monitoring in a porcine model using glucose clamp technique.

Authors:  Felix Aberer; Verena Theiler-Schwetz; Haris Ziko; Bettina Hausegger; Iris Wiederstein-Grasser; Daniel A Hochfellner; Philipp Eller; Georg Tomberger; Martin Ellmerer; Julia K Mader; Vladimir Bubalo
Journal:  Sci Rep       Date:  2020-04-20       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.