Literature DB >> 29392640

Corneal incision architecture after IOL implantation with three different injectors: an environmental scanning electron microscopy study.

Rita Mencucci1, Eleonora Favuzza2, Maria Cristina Salvatici3, Leopoldo Spadea4, David Allen5.   

Abstract

PURPOSE: To evaluate by Environmental Scanning Electron Microscopy (ESEM) the corneal incision architecture after intraocular lens (IOL) implantation in pig eyes, using manual, automated injectors or preloaded delivery systems.
METHODS: Twenty-four pig eyes underwent IOL implantation in the anterior chamber using three different injectors: manual (Monarch III) (n = 8), automated (AutoSert) (n = 8), or a preloaded system (UltraSert) (n = 8). Acrysof IQ IOLs, 21 Dioptres (D) (n = 12) and 27D (n = 12), were implanted through 2.2 mm clear corneal incisions. Incision width was measured using corneal calipers. The endothelial side of the incision was analyzed with ESEM.
RESULTS: In each group, the final size of the corneal wound after IOL implantation, measured by calipers, was 2.3-2.4 mm. The incision architecture resulted more irregular in the Monarch group compared with the other injectors. In every group the 27D IOL-implanted specimens showed more alterations than in 21D IOL-implanted samples, and this was less evident in the UltraSert group. The Descemet tear length was higher in the Monarch group than AutoSert and UltraSert group.
CONCLUSIONS: The automated and preloaded delivery systems provided a good corneal incision architecture; after high-power IOL implantation the incisions were more regular and less damaged with the preloaded system than with the other devices.

Entities:  

Keywords:  Cataract; Corneal incision; Environmental scanning electron microscopy; Injector; Intraocular lens; Preloaded injector

Mesh:

Year:  2018        PMID: 29392640     DOI: 10.1007/s10792-018-0825-2

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  5 in total

1.  In vivo and in vitro results of an automated preloaded delivery system for IOL implantation in cataract surgery.

Authors:  Leonardo Mastropasqua; Lisa Toto; Erminia D'Ugo; Manuela Lanzini; Peter A Mattei; Gennaro Falconio; Emanuele Doronzo; Francesca Diomede; Oriana Trubiani
Journal:  Int Ophthalmol       Date:  2019-08-26       Impact factor: 2.031

2.  Clinical Evaluation of a Novel Preloaded Intraocular Lens Delivery System During Routine Cataract Surgery.

Authors:  Daniel Black; Dean Corbett; Timothy V Roberts; Brendan Cronin; Pamela J Smith; D Priya Janakiraman; Beth E Jackson
Journal:  Clin Ophthalmol       Date:  2020-08-12

3.  Experimental Study on Delivery Performance of an Automated Preloaded Intraocular Lens Injector System for Corneal and Sclerocorneal Incisions.

Authors:  Tetsuro Oshika; Noriyuki Sasaki
Journal:  J Ophthalmol       Date:  2021-03-31       Impact factor: 1.909

4.  Multicenter Evaluation of Time, Operational, and Economic Efficiencies of a New Preloaded Intraocular Lens Delivery System versus Manual Intraocular Lens Delivery.

Authors:  Javier Mendicute; Lucia Bascarán; Luis Pablo; Cédric Schweitzer; Laurent Velasque; Christine Bouchet; Aldo A Martinez
Journal:  Clin Ophthalmol       Date:  2021-02-16

5.  Comparison of a new IOL injector system against 3 standard IOL injector systems with different incision sizes: Miyake-Apple view experimental laboratory study.

Authors:  Lu Zhang; Sonja Schickhardt; Hui Fang; Florian Auerbach; Perfecto Cagampang; Patrick R Merz; Gerd U Auffarth
Journal:  J Cataract Refract Surg       Date:  2022-02-01       Impact factor: 3.351

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.