Literature DB >> 29392301

Ultrasonography Assessments of Optic Nerve Sheath Diameter as a Noninvasive and Dynamic Method of Detecting Changes in Intracranial Pressure.

Li-Juan Wang1, Li-Min Chen1, Ying Chen1, Li-Yang Bao1, Nan-Nan Zheng1, Yu-Zhi Wang1, Ying-Qi Xing1.   

Abstract

Importance: The crtierion standard method for monitoring intracranial pressure (ICP) can result in complications and pain. Hence, noninvasive, repeatable methods would be valuable. Objective: To examine how ultrasonographic optic nerve sheath diameter (ONSD) correlated with noninvasive and dynamically monitored ICP changes. Design, Setting, and Participants: The ONSD was measured before the lumbar puncture (LP) in 60 patients on admission. Patients with elevated ICP were divided into group 1 (200 < LP ≤ 300 mm H2O) and group 2 (LP > 300 mm H2O). Patients underwent follow-up ONSD and LP measurements within 1 month. We analyzed the correlations between the ONSD and ICP on admission and between the changes in ONSD and ICP, which were the respective changes in ONSD and ICP from admission to follow-up. Main Outcomes and Measures: The ultrasonographic ONSD and ICP were measured on admission and follow-up. The correlations between the ONSD and ICP on admission and between the changes in ONSD and ICP were analyzed using Pearson correlation analyses.
Results: For 60 patients (Han nationality; mean [SD] age, 36.2 [12.04] years; 29 [48%] female) on admission, the ONSD and ICP values were strongly correlated, with an r of 0.798 (95% CI, 0.709-0.867; P < .001). Twenty-five patients with elevated ICP who completed the follow-up were included. The mean (SD) ONSD and ICP on admission were 4.50 (0.54) mm and 302.40 (54.26) mm H2O, respectively. The ONSD and ICP values obtained on admission were strongly correlated , with an r of 0.724 (95% CI, 0.470-0.876; P < .001). The mean (SD, range) changes in ICP and ONSD were 126.64 (52.51 mm H2O, 20-210 mm H2O) (95% CI, 106.24-146.07) and 1.00 (0.512 mm, 0.418-2.37 mm) (95% CI, 0.83-1.20), respectively. The change in ONSD was strongly correlated with the change in ICP, with an r of 0.702 (95% CI, 0.425-0.870; P < .001). The follow-up evaluations revealed that the elevated ICP and dilated ONSD had returned to normal, and no evidence of difference was found in the mean ONSDs between group 1 (3.49 mm; 95% CI, 3.34-3.62 mm) and group 2 (3.51 mm; 95% CI, 3.44-3.59 mm) (P = .778) at follow-up. Conclusions and Relevance: The dilated ONSDs decreased along with the elevated ICP reduction. Ultrasonographic ONSD measurements may be a useful, noninvasive tool for dynamically evaluating ICP.

Entities:  

Mesh:

Year:  2018        PMID: 29392301      PMCID: PMC5885896          DOI: 10.1001/jamaophthalmol.2017.6560

Source DB:  PubMed          Journal:  JAMA Ophthalmol        ISSN: 2168-6165            Impact factor:   7.389


  28 in total

1.  Ultrasound measurement of optic nerve sheath diameter in patients with a clinical suspicion of raised intracranial pressure.

Authors:  Robert Major; Simon Girling; Adrian Boyle
Journal:  Emerg Med J       Date:  2010-08-15       Impact factor: 2.740

2.  Intra- and interobsever reliability of sonographic assessment of the optic nerve sheath diameter in healthy adults.

Authors:  Jochen Bäuerle; Piergiorgio Lochner; Manfred Kaps; Max Nedelmann
Journal:  J Neuroimaging       Date:  2010-12-01       Impact factor: 2.486

3.  Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients.

Authors:  Vivek S Tayal; Matthew Neulander; H James Norton; Troy Foster; Timothy Saunders; Michael Blaivas
Journal:  Ann Emerg Med       Date:  2006-09-25       Impact factor: 5.721

Review 4.  Optic nerve sonography: a new window for the non-invasive evaluation of intracranial pressure in brain injury.

Authors:  T Soldatos; K Chatzimichail; M Papathanasiou; A Gouliamos
Journal:  Emerg Med J       Date:  2009-09       Impact factor: 2.740

5.  Effects of acute controlled changes in end-tidal carbon dioxide on the diameter of the optic nerve sheath: a transorbital ultrasonographic study in healthy volunteers.

Authors:  M Dinsmore; J S Han; J A Fisher; V W S Chan; L Venkatraghavan
Journal:  Anaesthesia       Date:  2017-02-08       Impact factor: 6.955

Review 6.  Ocular color-coded sonography - a promising tool for neurologists and intensive care physicians.

Authors:  M Ertl; F Barinka; E Torka; M Altmann; K Pfister; H Helbig; U Bogdahn; M A Gamulescu; F Schlachetzki
Journal:  Ultraschall Med       Date:  2014-03-19       Impact factor: 6.548

7.  Ultrasonographic Evaluation of Optic Nerve Sheath Diameter among Healthy Chinese Adults.

Authors:  Lijuan Wang; Liangshu Feng; Yan Yao; Fang Deng; Yuzhi Wang; Jiachun Feng; Yingqi Xing
Journal:  Ultrasound Med Biol       Date:  2015-12-29       Impact factor: 2.998

8.  Architecture of arachnoid trabeculae, pillars, and septa in the subarachnoid space of the human optic nerve: anatomy and clinical considerations.

Authors:  H E Killer; H R Laeng; J Flammer; P Groscurth
Journal:  Br J Ophthalmol       Date:  2003-06       Impact factor: 4.638

9.  Use of the sonographic diameter of optic nerve sheath to estimate intracranial pressure.

Authors:  Afshin Amini; Hamid Kariman; Ali Arhami Dolatabadi; Hamid Reza Hatamabadi; Hojjat Derakhshanfar; Behnam Mansouri; Saeed Safari; Razie Eqtesadi
Journal:  Am J Emerg Med       Date:  2012-08-31       Impact factor: 2.469

10.  Evaluation of Optical Coherence Tomography to Detect Elevated Intracranial Pressure in Children.

Authors:  Jordan W Swanson; Tomas S Aleman; Wen Xu; Gui-Shuang Ying; Wei Pan; Grant T Liu; Shih-Shan Lang; Gregory G Heuer; Phillip B Storm; Scott P Bartlett; William R Katowitz; Jesse A Taylor
Journal:  JAMA Ophthalmol       Date:  2017-04-01       Impact factor: 7.389

View more
  21 in total

1.  Reply to the Comment Entitled "The Utility of Ocular Ultrasonography to Evaluate the Influence of Tourniquet Application on Intracranial Pressure".

Authors:  Ahmet Besir; Ersagun Tugcugil
Journal:  Med Princ Pract       Date:  2019-07-08       Impact factor: 1.927

2.  Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis.

Authors:  Chiara Robba; Gregorio Santori; Marek Czosnyka; Francesco Corradi; Nicola Bragazzi; Llewellyn Padayachy; Fabio Silvio Taccone; Giuseppe Citerio
Journal:  Intensive Care Med       Date:  2018-07-17       Impact factor: 17.440

3.  The relation of optic nerve sheath diameter (ONSD) and intracranial pressure (ICP) in pediatric neurosurgery practice - Part II: Influence of wakefulness, method of ICP measurement, intra-individual ONSD-ICP correlation and changes after therapy.

Authors:  Susanne R Kerscher; Daniel Schöni; Felix Neunhoeffer; Markus Wolff; Karin Haas-Lude; Andrea Bevot; Martin U Schuhmann
Journal:  Childs Nerv Syst       Date:  2019-08-08       Impact factor: 1.475

4.  Relation between partial arterial carbon dioxide pressure and pH value and optic nerve sheath diameter: a prospective self-controlled non-randomized trial study.

Authors:  Murat Duyan; Ali Saridas
Journal:  J Ultrasound       Date:  2022-05-05

5.  Association of serum retinol concentration with normal-tension glaucoma.

Authors:  Ruiqi Pang; Shuo Feng; Kai Cao; Yunxiao Sun; Yiqin Guo; Dandan Ma; Chi Pui Pang; Xiangyi Liu; Jingyu Qian; Yuan Xie; Yan Shi; Hailong He; Jun Peng; Congyan Chen; Jing Cui; Siloka A Labisi; Yue Zhang; Yingdi Fu; Jiaying Li; Yue Wan; Chen Xin; Hanruo Liu; Qing Zhang; Robert N Weinreb; Huaizhou Wang; Ningli Wang
Journal:  Eye (Lond)       Date:  2021-08-12       Impact factor: 4.456

6.  Can Optic Nerve Sheath Images on a Thin-Slice Brain Computed Tomography Reconstruction Predict the Neurological Outcomes in Cardiac Arrest Survivors?

Authors:  Sung Ho Kwon; Sang Hoon Oh; Jinhee Jang; Soo Hyun Kim; Kyu Nam Park; Chun Song Youn; Han Joon Kim; Jee Yong Lim; Hyo Joon Kim; Hyo Jin Bang
Journal:  J Clin Med       Date:  2022-06-26       Impact factor: 4.964

7.  Optic nerve sheath diameter does not correlate with intracranial pressure in pediatric neurocritical care patients.

Authors:  Austin Biggs; Marlina Lovett; Melissa Moore-Clingenpeel; Nicole O'Brien
Journal:  Childs Nerv Syst       Date:  2020-10-03       Impact factor: 1.475

8.  Patient management algorithm combining processed electroencephalographic monitoring with cerebral and somatic near-infrared spectroscopy: a case series.

Authors:  Etienne J Couture; Alain Deschamps; André Y Denault
Journal:  Can J Anaesth       Date:  2019-02-01       Impact factor: 5.063

Review 9.  Neuro-ophthalmic manifestations of tuberculosis.

Authors:  Rebika Dhiman; Subodh Lakra; Prateek Kumar Panda; Naren Hemachandran; Sanjay Sharma; Rohit Saxena
Journal:  Eye (Lond)       Date:  2021-06-14       Impact factor: 3.775

10.  [Clinical efficacy of restrictive fluid management in patients with severe traumatic brain injury].

Authors:  Shibing Zhao; Decai Xu; Rui Li; Qi Zou; Zhenzhen Chen; Huaxue Wang; Xiandi He
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2021-01-30
View more