Literature DB >> 29387695

The resectable pancreatic lesion: To FNA or not to FNA? A diagnostic dilemma, FNA cons.

Anand V Sahai1.   

Abstract

Entities:  

Year:  2017        PMID: 29387695      PMCID: PMC5774078          DOI: 10.4103/eus.eus_65_17

Source DB:  PubMed          Journal:  Endosc Ultrasound        ISSN: 2226-7190            Impact factor:   5.628


× No keyword cloud information.
Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is generally safe and very effective, but there are risks. When the risks outweigh the benefits, fine-needle aspiration (FNA) should not be performed. However, as such cases are rare, true FNA “cons” are rare. The best way to reduce the risk of EUS-FNA complications is to not perform EUS-FNA. FNA should never be performed unless there is a reasonable expectation that the information provided will truly help improve patient management. Paradoxically, FNA results positive for malignancy are not universally helpful while those negative for malignancy or not universally unhelpful. Whatever the results, FNA-related complications in cases where the information was unlikely to be helpful to begin with, may be hard to justify medicolegally. The most common risks directly attributable to EUS-guided punctures are bleeding, pancreatitis, and infection (primarily of cystic lesions). These occur in <2% of cases.[1] To some extent, the frequency can likely be reduced with an improved EUS technique, such as avoiding vessels, reducing the number of passes, and avoiding traversing large areas of normal pancreas. The utility of EUS-cyst fluid analysis for cystic lesions is debatable in many cases. If a cyst puncture is considered essential, it is probably best to never puncture a cyst more than once with the same needle and to administer prophylactic antibiotics before and/or after the procedure. Another less obvious risk is that of incorrect EUS-FNA results (false positive and false negative). False positives are out of the control of the endosonographer and can have a serious adverse clinical impact, as they are usually discovered after surgery, usually unnecessarily, because the pathological study of the surgical specimen shows no evidence of malignancy. The impact of a false negative can usually be minimized by repeating the EUS-FNA when clinical suspicion of malignancy remains high, despite initial negative results. The risk of these complications is so low that it is not worth considering if there is a reasonable suspicion of pancreatic cancer. However, if the suspicion for cancer is relatively low, the risks may be unjustified. It is particularly important to avoid biopsy of low-suspicion lesions in the recent acute pancreatitis since these may represent poorly organized cysts or necrosis, which are at risk for infection, or well-encapsulated, microcystic lesions, which are usually typical for benign serous cystadenomas and are also at risk for FNA-induced infections. Perhaps, the most serious complication of EUS-FNA is tumor seeding during the trans-gastric EUS-FNA of pancreatic body lesions. It is very rare, but it does occur.[234] The data from underpowered retrospective studies showing no influence of EUS-FNA on survival or peritoneal failure do not prove that tumor seeding is of no consequence since there are several well-documented cases in the literature.[56] Tumor seeding can turn a potentially curable T1 lesion into a locally advanced T4 or metastatic M1 lesion. Therefore, the risks of tumor seeding may contraindicate EUS-FNA for very suspicious, clearly resectable pancreatic body lesions. EUS-FNA is a powerful, effective, and generally extremely safe tool. There are few reasons to not perform EUS-FNA in suspicious lesions. However, for less suspicious lesions or for highly suspected, resectable body lesions, serious consideration should be given as to whether the risks outweigh any potential benefits.
  6 in total

1.  Case of intraductal papillary mucinous tumor in which endosonography-guided fine-needle aspiration biopsy caused dissemination.

Authors:  Yoshiki Hirooka; Hidemi Goto; Akihiro Itoh; Senju Hashimoto; Katsushi Niwa; Hideki Ishikawa; Naoto Okada; Terutomo Itoh; Hiroki Kawashima
Journal:  J Gastroenterol Hepatol       Date:  2003-11       Impact factor: 4.029

2.  Melanoma seeding of an EUS-guided fine needle track.

Authors:  Janak N Shah; Douglas Fraker; DuPont Guerry; Michael Feldman; Michael L Kochman
Journal:  Gastrointest Endosc       Date:  2004-06       Impact factor: 9.427

3.  A first report of tumor seeding because of EUS-guided FNA of a pancreatic adenocarcinoma.

Authors:  Sarto C Paquin; Gilles Gariépy; Luigi Lepanto; Raymond Bourdages; Ginette Raymond; Anand V Sahai
Journal:  Gastrointest Endosc       Date:  2005-04       Impact factor: 9.427

Review 4.  Complications of diagnostic and therapeutic Endoscopic Ultrasound.

Authors:  Sundeep Lakhtakia
Journal:  Best Pract Res Clin Gastroenterol       Date:  2016-10-28       Impact factor: 3.043

5.  Preoperative endoscopic ultrasound-guided fine needle aspiration does not impair survival of patients with resected pancreatic cancer.

Authors:  Saowanee Ngamruengphong; Kristi M Swanson; Nilay D Shah; Michael B Wallace
Journal:  Gut       Date:  2015-01-09       Impact factor: 23.059

6.  Lower frequency of peritoneal carcinomatosis in patients with pancreatic cancer diagnosed by EUS-guided FNA vs. percutaneous FNA.

Authors:  Carlos Micames; Paul S Jowell; Rebekah White; Erik Paulson; Rendon Nelson; Michael Morse; Herbert Hurwitz; Theodore Pappas; Douglas Tyler; Kevin McGrath
Journal:  Gastrointest Endosc       Date:  2003-11       Impact factor: 9.427

  6 in total
  2 in total

1.  Utility of endoscopic ultrasound-guided fine-needle aspiration in pancreatic cancer patients who failed to obtain a pathological diagnosis in surgical exploration.

Authors:  Meng-Jiang He; Tian-Yin Chen; Xin-Yang Liu; Xiao-Yue Xu; Ping-Hong Zhou; Yi-Qun Zhang
Journal:  Gland Surg       Date:  2022-02

2.  Rapid on-site evaluation (ROSE) with EUS-FNA: The ROSE looks beautiful.

Authors:  Fei Yang; Enshuo Liu; Siyu Sun
Journal:  Endosc Ultrasound       Date:  2019 Sep-Oct       Impact factor: 5.628

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.