Literature DB >> 29386815

Comparison of the effectiveness of Tokuyama and GC II metal primer on the bond strength of acrylic resins to Ti-6Al-7Nb.

Sunit Kumar Jurel1, Niraj Mishra1, Pooran Chand1, Himanshi Aggarwal1, Raghuwar Dayal Singh1, Balendra Pratap Singh1.   

Abstract

STATEMENT OF PROBLEM: Because of the toxicity of vanadium in Ti-6Al-4V alloy, next generation of titanium alloys is proposed to focus on niobium-containing alloy, but for clinical applications, it is crucial for this alloy to bond with acrylic resins with or without the use of primers. However, literature was lacking about the effect of primers on bonding of autopolymerizing resins to Ti-6Al-7Nb.
OBJECTIVES: To evaluate the effect of different metal primers on the shear bond strength of acrylic resin to Ti-6Al-7Nb.
MATERIALS AND METHODS: A total of 30 dis-shaped wax patterns (10 mm in diameter and 2 mm thickness) were prepared and casted using Ti-6Al-7Nb. After casting, the disk surfaces were finished with abrasive paper under water. Specimens were equally divided into three groups on the basis of the use of primer: metal primer (GC II metal primer) (Group 1), Universal Tokuyama primer (Group 2), no primer (Group 3). Tape of 50 μm thickness was applied on each of the specimens. Then, self-cure acrylic resin was mixed and applied on the center part of the tape, on which Bernouilles tube was placed. The tensile bond strength was measured with a universal testing machine. The data were obtained for all the specimens and analyzed using Statistical Package for Social Sciences version 17.0 at a statistically significance level of <0.05.
RESULTS: Mean tensile force was maximum for Group 2 (28.58 ± 39.40 N) and minimum for control Group 3 (6.24 ± 10.97 N), thereby showing a significant inter-group difference (P < 0.001). On applying post hoc test (Tukey HSD), both the Group 1 and Group 2 showed a statistically significant difference as compared to control Group 3; however, the difference between two experimental groups was not statistically significant (P > 0.05).
CONCLUSIONS: Tokuyama primer and GC II metal primer had a significant effect on improving the bond strength between autopolymerizing denture base resin and Ti-6Al-7Nb.

Entities:  

Keywords:  Autopolymerizing resin; bond strength; in vitro; primer; titanium alloy

Year:  2017        PMID: 29386815      PMCID: PMC5773986          DOI: 10.4103/0975-5950.221704

Source DB:  PubMed          Journal:  Natl J Maxillofac Surg        ISSN: 0975-5950


INTRODUCTION

In removable prosthodontics, sufficient bonding is desirable between the cast metal-based partial or complete denture framework and the denture base resin. Poor chemical bonding of the metal-resin interface may result in significant clinical problems, often introducing adhesive failure and increasing microleakage of oral fluids in the finish lines, which causes an accumulation of oral debris, microorganisms, and stains.[123] Another significant clinical and esthetic problem associated with removable prostheses is the discoloration or staining caused by microleakage. Therefore, optimizing bond strength at the resin-metal interface of a removable partial denture (RPD) is essential for the success of the prosthesis.[456] The differences in the coefficient of thermal expansion between acrylic resins and alloys, and the polymerization shrinkage of acrylic resin, may result in separation of these materials.[7] Resin-to-metal and resin-to-denture tooth bonds are stressed by laboratory procedures during the fabrication of RPDs.[8] The use of titanium and titanium alloys for cast restorations, denture frameworks, and milled prostheses has increased substantially,[9] and several systems have been introduced increasing the bond strength between acrylic resin and RPD casting alloys.[10] One important improvement in resin bonding techniques has been the introduction of chemical metal-resin bonding systems.[11121314] Recently, Ohkubo et al.[11] studied the effect of the application of metal conditioners to cast commercially pure (CP) titanium, titanium alloy (Ti-6Al-4V), and Co–Cr alloy. Semlitsch et al.[15] developed a titanium-aluminum alloy with the inert alloying element niobium and found the optimal composition should be Ti-6Al-7Nb. This alloy had outstanding biocompatibility,[16] good mechanical properties and corrosion resistance,[17] reliable casting properties,[12] and improved wear resistance.[1314] Yanagida et al.[18] evaluated the effect of metal conditioners and a surface modification system on the bond durability between a light-activated prosthetic composite material and Ti-6Al-7Nb. In their study, the use of the primers was found to enhance bonding. Furthermore, Yanagida et al.[19] evaluated the adhesive performance of metal conditioners used for bonding between autopolymerizing methacrylate resins and a titanium alloy, and reported that the use of one of the three conditioners (Alloy Primer, Cesead II Opaque Primer, and Metal Prime II) in combination with autopolymerizing luting resin consisting of methyl methacrylate and tri-n-butylborane with 4-methacryloyloxyethyl trimellitate anhydride (Super-Bond C and B) is recommended for bonding to the Ti-6Al-7Nb alloy. Several adhesive primers, including Meta Fast (Sun Medical Co. Ltd., Shiga, Japan), containing 4-META monomer, and metal primer (Ivoclar Vivadent AG, Schaan, Liechtenstein), containing 10-methacryloyloxydecyl dihydrogen phosphate, have been developed and are commercially available for resin-bonded prostheses, composite-veneered prostheses, and RPDs.[11] Numerous studies have evaluated the effect of such primers on bonding acrylic resin to Ti-6Al-4V and CP-Ti. However, there is insufficient information about the effect of such primers on bonding of autopolymerizing polymethyl methacrylate (PMMA) resins to Ti-6Al-7Nb. Hence, the purpose of this study was to compare the effectiveness of Tokuyama primer and GC II primer on tensile bond strength of autopolymerizing PMMA resins to Ti-6Al-7Nb.

MATERIALS AND METHODS

A total of 30 disk-shaped wax patterns (10 mm in diameter and 2 mm thickness) were prepared and casted using a titanium alloy (Ti-6Al-7Nb), according to the manufacturer's instructions. After casting, the disk surfaces were finished with 600-grit SiC abrasive paper (CarbiMet; Buehler Ltd., Lake Bluff, Ill) under water. To each titanium disc, nuts were fixed with araldite (fixing material), and they were sandblasted with 50 μm particle sized sand at 2.5 bar pressure. After sandblasting, all specimens were steam-cleaned and kept in temperature bath for at 37°C for 24 h. The discs were then removed from temperature bath and tape of 50 μm thickness (bearing central hole) was applied on all the specimens. The specimens were now ready for testing[Figure 1], and equally divided into three groups with ten titanium plates in each group: Group 1 with GC II metal primer, Group 2 with Universal Tokuyama primer, Group 3 with no primer which acts as control group.
Figure 1

Titanium specimens used in the study

Titanium specimens used in the study The metal primer (GC Corporation Ltd., Tokyo, Japan) was applied with the applicator tip on all the 10 specimens of Group 1. Then, self-cure acrylic resin (UNIFAST III; GC Corp., Tokyo, Japan) was mixed in ratio 1 g powder/0.5 ml liquid and applied on the center part of the tape, on which Bernouilles tube was placed. It was cured at room temperature (23 ± 1°C; humidity 50–60%) and after keeping undisturbed for about 10–15 min, all the specimens with the attached tubes as shown inFigure 2, was placed in hot air oven at 37°C for 24 h. The universal primer (Tokuyama Dental Corp., Japan) was applied over all the specimens of Group 2 and similar procedure was performed as described for Group 1. Same procedure was performed for Group 3 specimens, but without applying any primer over the disc surface.
Figure 2

Specimens with the attached bernouilles tubes ready for testing

Specimens with the attached bernouilles tubes ready for testing The tensile bond strength was measured with a universal testing machine (TSTM 02500; Elista, Istanbul, Turkey), using a crosshead speed of 0.5 mm/min[ Figure 3]. The data were obtained for all the specimens, and it was analyzed using Statistical Package for Social Sciences version 17.0 (SPSS Inc., Chicago, IL). Intergroup comparison was done using analysis of variance followed by Tukey HSD test as the post hoc assessment tool. The confidence level of the study was kept at 95%, hence a P < 0.05 indicated a statistically significant difference.
Figure 3

Universal testing machine used in the study

Universal testing machine used in the study

RESULTS

Graph 1 summarizes the means and standard deviations of the tensile force of the three groups. The results indicate that the mean tensile force was maximum for Universal Tokuyama primer (28.58 ± 39.40 N) and minimum for control group (6.24 ± 10.97 N), thereby showing a significant intergroup difference (F = 41.966; P < 0.001). On applying post hoc test (Tukey HSD), GC II metal primer and Universal Tokuyama primer showed a statistically significant difference as compared to control group. However, the difference between two GC II metal primer and Universal Tokuyama primer was not significant statistically (P > 0.05).
Graph 1

Graphical view of tensile force in different groups. Group 1 - GC primer II; Group 2 - Tokuyama primer; Group 3 - No primer (control)

Graphical view of tensile force in different groups. Group 1 - GC primer II; Group 2 - Tokuyama primer; Group 3 - No primer (control)

DISCUSSION

The current study evaluated the effect of GC Primer II and Tokuyama Primer on tensile bond strengths between an autopolymerizing PMMA resin to Ti-6Al-7Nb. As there are serious concerns on the toxicity of vanadium in Ti-6Al-4V alloy, so the next generation of titanium alloys is proposed to focus on niobium-containing alloy.[20] However, the superior biological[20] and mechanical[21] properties of Ti-6Al-7Nb do not warrant their extensive application in dentistry unless this alloy can be used as an alternative to Ti-6Al-4V or CP-Ti. For practical applications of Ti-6Al-7Nb in prosthodontics, it is crucial for this alloy to bond with acrylic resins with or without the use of primers. In our study, airborne-particle abrasion was employed to create surface roughness by cleaning the surface of metal oxides and other substances, to increase the mechanical and chemical bond strength between metal and acrylic resin.[9] As the choice of a chemical bonding system for prosthodontic applications depends on factors such as expense, availability, time requirements, and the shelf life of the perishable components.[22] However, a control group (Group 3) was also formed in the present study to check whether the need of primer to bond titanium alloy to acrylic resin could be eliminated. However, it was found that bond strength in this group was approximately four times less than the primer treated groups (Group 1 and 2) as shown in Graph 1. Numerous studies have established that application of primers significantly improve the bond strength of the acrylic resin to the cast metals, Ti-6Al-4 V, CP-Ti, composites, and ceramics.[891023242526272829303132] However, the comparative evaluations of bond strength between acrylic resin and Ti-6Al-7Nb with the use of Tokuyama primer and GC II metal primer have never been documented. In the present study, the tensile bond strength of Ti-6Al-7Nb to acrylic resins was significantly (P < 0.001) improved by primer application compared to control group [Graph 1]. The mean tensile force was maximum for Group 2 (28.58 ± 39.40 N) and minimum for control Group 3 (6.24 ± 10.97 N), thereby showing a statistically significant intergroup difference (F = 41.966; P < 0.001) Therefore, both Tokuyama primer and GC II metal primer had a statistically significant effect on improving the bond between the autopolymerizing denture base resin and Ti-6Al-7Nb, which can make this alloy feasible for use in removable prosthodontics. However, as tensile bond strength is not the only factor that may influence the durability of resin-metal bonds, so careful interpretation in the clinical application of these results is suggested, as the design of the present study, did not consider factors existing in the oral environment, such as dynamic fatigue loading and pH changes. The efficacy of the tested systems in providing reliable bond strength needs to be confirmed by long-term clinical studies.

Conclusions

Within the limitation of this in vitro study, it can be concluded that both Tokuyama primer and GC II metal primer had a statistically significant effect on improving the bond strength between autopolymerizing denture base resin and Ti-6Al-7Nb, which can make this alloy feasible for the use in removable prosthodontics as a safe alternative to Ti-6Al-4V.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  32 in total

1.  In vitro wear assessment of titanium alloy teeth.

Authors:  Chikahiro Ohkubo; Ichiro Shimura; Takayuki Aoki; Shigeru Hanatani; Toshio Hosoi; Toru Okabe
Journal:  J Prosthodont       Date:  2002-12       Impact factor: 2.752

Review 2.  Alternative alloys for resin-bonded retainers.

Authors:  J R Lawson
Journal:  J Prosthet Dent       Date:  1991-01       Impact factor: 3.426

3.  Adhesive-fixed partial dentures in anterior and posterior areas. Results of an on-going prospective study begun in 1985.

Authors:  M Behr; A Leibrock; W Stich; P Rammelsberg; M Rosentritt; G Handel
Journal:  Clin Oral Investig       Date:  1998-03       Impact factor: 3.573

4.  Adhesive bonding of resin cements to cast titanium with adhesive primers.

Authors:  Marina Di Francescantonio; Marcelo Tavares de Oliveira; Luiz Gustavo Dias Daroz; Guilherme Elias Pessanha Henriques; Marcelo Giannini
Journal:  Braz Dent J       Date:  2012

5.  Clinical results with resin-bonded prostheses and an adhesive cement.

Authors:  O Hansson
Journal:  Quintessence Int       Date:  1994-02       Impact factor: 1.677

6.  Shear bond strength between autopolymerizing acrylic resin and Co-Cr alloy using different primers.

Authors:  Sasiwimol Sanohkan; Somchai Urapepon; Choltacha Harnirattisai; Chakrit Sirisinha; Panya Sunintaboon
Journal:  Dent Mater J       Date:  2012       Impact factor: 2.102

7.  Castability of Ti-6Al-7Nb alloy for dental casting.

Authors:  T J Wang; E Kobayashi; H Doi; T Yoneyama
Journal:  J Med Dent Sci       Date:  1999-03

8.  Adhesive bonding of titanium-aluminum-niobium alloy with nine surface preparations and three self-curing resins.

Authors:  Hiroaki Yanagida; Yohsuke Taira; Saiji Shimoe; Mitsuru Atsuta; Takayuki Yoneyama; Hideo Matsumura
Journal:  Eur J Oral Sci       Date:  2003-04       Impact factor: 2.612

9.  Joint replacement components made of hot-forged and surface-treated Ti-6Al-7Nb alloy.

Authors:  M F Semlitsch; H Weber; R M Streicher; R Schön
Journal:  Biomaterials       Date:  1992       Impact factor: 12.479

10.  Wear properties of Ti and Ti-6Al-7Nb castings for dental prostheses.

Authors:  D Iijima; T Yoneyama; H Doi; H Hamanaka; N Kurosaki
Journal:  Biomaterials       Date:  2003-04       Impact factor: 12.479

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.