Literature DB >> 29374401

Inter-rater and intra-rater reliability of the airway diameter measured by sonography.

Julio César Gómez-Tamayo1, Jorge Iván Puerta-Guarín2, Claudia Marcela Rojas-Camejo2, Juan Pablo Caicedo2, José Andrés Calvache2,3.   

Abstract

INTRODUCTION: Sonography has gained a broad field of applications in current anesthetic practice. During airway management, it could have an important role, because it allows real-time measurement of anatomical aspects and a functional evaluation with high safety profile. However, assessment of the reliability and precision of these measurements is critical if sonography is used as a clinical diagnostic tool. The aim of the study was to estimate inter-rater and intra-rater reliability of the airway diameter measured by sonography in heathy volunteers.
METHODS: We conducted a cross-sectional study during 2015 on healthy adult volunteers. Using sonography, transverse internal diameter of subglottic space was measured twice by two blinded sonographers.
RESULTS: Agreement was classified as very good for intra-rater measurements (ICC = 0.84) and good for the inter-rater measurements (ICC = 0.71). The 95% CI of agreement limits for the intra-rater measurements were inferior to those for the inter-rater measurements.
CONCLUSIONS: Ultrasound measurement is a reliable and precise method to measure the internal subglottic diameter of the airway. Ultimately, this method may provide clinicians valuable information regarding airway diameter in adults and may help to guide treatment options.

Keywords:  Airway; Airway ultrasound; Precision; Reliability; Sonography; Subglottic space

Mesh:

Year:  2018        PMID: 29374401      PMCID: PMC5845935          DOI: 10.1007/s40477-017-0276-z

Source DB:  PubMed          Journal:  J Ultrasound        ISSN: 1876-7931


  23 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  Accuracy and repeatability of prostate volume measurements by transrectal ultrasound.

Authors:  L M Eri; H Thomassen; B Brennhovd; L L Håheim
Journal:  Prostate Cancer Prostatic Dis       Date:  2002       Impact factor: 5.554

Review 3.  Applying the right statistics: analyses of measurement studies.

Authors:  J M Bland; D G Altman
Journal:  Ultrasound Obstet Gynecol       Date:  2003-07       Impact factor: 7.299

4.  Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed.

Authors:  Jan Kottner; Laurent Audigé; Stig Brorson; Allan Donner; Byron J Gajewski; Asbjørn Hróbjartsson; Chris Roberts; Mohamed Shoukri; David L Streiner
Journal:  J Clin Epidemiol       Date:  2010-06-17       Impact factor: 6.437

5.  Anesthesiologists & Ultrasonography: A Historical Window.

Authors:  Jonathan P Wanderer; James P Rathmell
Journal:  Anesthesiology       Date:  2015-09       Impact factor: 7.892

6.  Role of ultrasound compared to age-related formulas for uncuffed endotracheal intubation in a pediatric population.

Authors:  Christoph Schramm; Jana Knop; Katrin Jensen; Konstanze Plaschke
Journal:  Paediatr Anaesth       Date:  2012-05-21       Impact factor: 2.556

7.  Work of breathing through different sized endotracheal tubes.

Authors:  M Shapiro; R K Wilson; G Casar; K Bloom; R B Teague
Journal:  Crit Care Med       Date:  1986-12       Impact factor: 7.598

8.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

9.  Statistical methodology for the concurrent assessment of interrater and intrarater reliability: using goniometric measurements as an example.

Authors:  M Eliasziw; S L Young; M G Woodbury; K Fryday-Field
Journal:  Phys Ther       Date:  1994-08

10.  Ultrasound measurements of the liver: an intra and inter-rater reliability study.

Authors:  Jessie T Childs; Adrian J Esterman; Kerry A Thoirs
Journal:  Australas J Ultrasound Med       Date:  2015-12-31
View more
  4 in total

1.  Real-time robotic airway measurement: An additional benefit of a novel steady-hand robotic platform.

Authors:  Christopher R Razavi; Francis X Creighton; Paul R Wilkening; Joseph Peine; Russell H Taylor; Lee M Akst
Journal:  Laryngoscope       Date:  2018-11-15       Impact factor: 3.325

2.  Evaluation of Tracheal Stenosis in Rabbits Using Multispectral Optoacoustic Tomography.

Authors:  Yanting Wen; Dan Wu; Jing Zhang; Shixie Jiang; Chunyan Xiong; Dan Guo; Zihui Chi; Yi Chen; Lun Li; Ying Yang; Ting Liu; Huabei Jiang
Journal:  Front Bioeng Biotechnol       Date:  2022-03-04

3.  The accuracy of ultrasound to predict endotracheal tube size for pediatric patients with congenital scoliosis.

Authors:  Jianhong Hao; Jie Zhang; Buhuai Dong; Zhenguo Luo
Journal:  BMC Anesthesiol       Date:  2020-07-31       Impact factor: 2.217

4.  Assessing the accuracy of ultrasound measurements of tracheal diameter: an in vitro experimental study.

Authors:  Ran Ye; Feifei Cai; Chengnan Guo; Xiaocheng Zhang; Dan Yan; Chengshui Chen; Bin Chen
Journal:  BMC Anesthesiol       Date:  2021-06-24       Impact factor: 2.217

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.