Literature DB >> 29372571

Snapshot-CEST: Optimizing spiral-centric-reordered gradient echo acquisition for fast and robust 3D CEST MRI at 9.4 T.

Moritz Zaiss1, Philipp Ehses1, Klaus Scheffler1,2.   

Abstract

Gradient echo (GRE)-based acquisition provides a robust readout method for chemical exchange saturation transfer (CEST) at ultrahigh field (UHF). To develop a snapshot-CEST approach, the transient GRE signal and point spread function were investigated in detail, leading to optimized measurement parameters and reordering schemes for fast and robust volumetric CEST imaging. Simulation of the transient GRE signal was used to determine the optimal sequence parameters and the maximum feasible number of k-space lines. Point spread function analysis provided an insight into the induced k-space filtering and the performance of different rectangular reordering schemes in terms of blurring, signal-to-noise ratio (SNR) and relaxation dependence. Simulation results were confirmed in magnetic resonance imaging (MRI) measurements of healthy subjects. Minimal repetition time (TR) is beneficial for snapshot-GRE readout. At 9.4 T, for TR = 4 ms and optimal flip angle close to the Ernst angle, a maximum of 562 k-space lines can be acquired after a single presaturation, providing decent SNR with high image quality. For spiral-centric reordered k-space acquisition, the image quality can be further improved using a rectangular spiral reordering scheme adjusted to the field of view. Application of the derived snapshot-CEST sequence for fast imaging acquisition in the human brain at 9.4 T shows excellent image quality in amide and nuclear Overhauser enhancement (NOE), and enables guanidyl CEST detection. The proposed snapshot-CEST establishes a fast and robust volumetric CEST approach ready for the imaging of known and novel exchange-weighted contrasts at UHF.
Copyright © 2018 John Wiley & Sons, Ltd.

Entities:  

Keywords:  9.4 T; APT; CEST; NOE; UHF; chemical exchange saturation transfer; human brain; snapshot

Mesh:

Year:  2018        PMID: 29372571     DOI: 10.1002/nbm.3879

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  17 in total

1.  Real-time simultaneous shim and motion measurement and correction in glycoCEST MRI using double volumetric navigators (DvNavs).

Authors:  Gizeaddis L Simegn; Andre J W Van der Kouwe; Frances C Robertson; Ernesta M Meintjes; Ali Alhamud
Journal:  Magn Reson Med       Date:  2018-12-02       Impact factor: 4.668

2.  Assessment of frequency drift on CEST MRI and dynamic correction: application to gagCEST at 7 T.

Authors:  Johannes Windschuh; Moritz Zaiss; Philipp Ehses; Jae-Seung Lee; Alexej Jerschow; Ravinder R Regatte
Journal:  Magn Reson Med       Date:  2018-05-31       Impact factor: 4.668

3.  Renal pH Imaging Using Chemical Exchange Saturation Transfer (CEST) MRI: Basic Concept.

Authors:  Dario Livio Longo; Pietro Irrera; Lorena Consolino; Phillip Zhe Sun; Michael T McMahon
Journal:  Methods Mol Biol       Date:  2021

4.  Prospective acceleration of parallel RF transmission-based 3D chemical exchange saturation transfer imaging with compressed sensing.

Authors:  Hye-Young Heo; Xiang Xu; Shanshan Jiang; Yansong Zhao; Jochen Keupp; Kristin J Redmond; John Laterra; Peter C M van Zijl; Jinyuan Zhou
Journal:  Magn Reson Med       Date:  2019-06-17       Impact factor: 4.668

5.  Quantitative kinetic modelling and mapping of cerebral glucose transport and metabolism using glucoCESL MRI.

Authors:  Ben R Dickie; Tao Jin; Ping Wang; Rainer Hinz; William Harris; Hervé Boutin; Geoff Jm Parker; Laura M Parkes; Julian C Matthews
Journal:  J Cereb Blood Flow Metab       Date:  2022-06-23       Impact factor: 6.960

6.  Whole-brain steady-state CEST at 3 T using MR Multitasking.

Authors:  Pei Han; Karandeep Cheema; Hsu-Lei Lee; Zhengwei Zhou; Tianle Cao; Sen Ma; Nan Wang; Hui Han; Anthony G Christodoulou; Debiao Li
Journal:  Magn Reson Med       Date:  2021-11-29       Impact factor: 3.737

7.  7T Magnetic Resonance Imaging Quantification of Brain Glutamate in Acute Ischaemic Stroke.

Authors:  John-Paul Nicolo; Bradford Moffat; David K Wright; Benjamin Sinclair; Andrew Neal; Elaine Lui; Patricia Desmond; Rebecca Glarin; Kathryn A Davis; Ravinder Reddy; Bernard Yan; Terence J O'Brien; Patrick Kwan
Journal:  J Stroke       Date:  2021-05-31       Impact factor: 6.967

8.  Pulseq-CEST: Towards multi-site multi-vendor compatibility and reproducibility of CEST experiments using an open-source sequence standard.

Authors:  Kai Herz; Sebastian Mueller; Or Perlman; Maxim Zaitsev; Linda Knutsson; Phillip Zhe Sun; Jinyuan Zhou; Peter van Zijl; Kerstin Heinecke; Patrick Schuenke; Christian T Farrar; Manuel Schmidt; Arnd Dörfler; Klaus Scheffler; Moritz Zaiss
Journal:  Magn Reson Med       Date:  2021-05-07       Impact factor: 3.737

9.  Whole-brain amide CEST imaging at 3T with a steady-state radial MRI acquisition.

Authors:  Ran Sui; Lin Chen; Yuguo Li; Jianpan Huang; Kannie W Y Chan; Xiang Xu; Peter C M van Zijl; Jiadi Xu
Journal:  Magn Reson Med       Date:  2021-03-27       Impact factor: 3.737

10.  Does the magnetization transfer effect bias chemical exchange saturation transfer effects? Quantifying chemical exchange saturation transfer in the presence of magnetization transfer.

Authors:  Alex K Smith; Kevin J Ray; James R Larkin; Martin Craig; Seth A Smith; Michael A Chappell
Journal:  Magn Reson Med       Date:  2020-02-18       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.