Accuracy of Digital Tomosynthesis With Metal Artifact Reduction for Detecting Osteointegration in Cementless Hip Arthroplasty.

Shengjie Guo1, Hao Tang1, Yixin Zhou1, Yong Huang1, Hongyi Shao1, Dejin Yang1.   

Abstract

BACKGROUND: Cementless hip arthroplasty is increasingly gaining popularity worldwide. Radiologic identification of osteointegration is key to confirming biologic fixation. We conducted the study reported here to determine the sensitivity and specificity of digital tomosynthesis with metal artifact reduction (TMAR), radiography, and conventional computed tomography in detecting osteointegration in cementless hip arthroplasty.
METHODS: We prospectively included data for 24 patients who underwent revision hip arthroplasty in our hospital, with 13 femoral and 14 acetabular cementless components retrieved that contained solid evidence of biologic fixation. All patients underwent 3 examinations before surgery, and evidence of osteointegration on retrieved prostheses was used as the reference standard. Seven orthopedic surgeons evaluated these images independently using uniform criteria.
RESULTS: On the femoral side, the sensitivity and specificity of detecting osteointegration were 73.8% ± 4.6% and 94.3% ± 1.5%, respectively, for TMAR; 50.4% ± 5.3% and 87.8% ± 2.1%, respectively, for radiography; and 36.4% ± 5.1% and 90.9% ± 1.9%, respectively, for CT. On the cup side, the corresponding values were 60.2% ± 8.3% and 86.4% ± 5.7%, respectively, for TMAR; 45.9% ± 8.5% and 66.4% ± 7.8%, respectively, for radiography; and 45.1% ± 8.5% and 73.5% ± 7.3%, respectively, by computed tomography.
CONCLUSION: TMAR significantly improved the accuracy osteointegration detection in cementless hip arthroplasty (P < .017).
Copyright © 2017. Published by Elsevier Inc.

Entities:  

Keywords:  cementless hip arthroplasty; digital tomosynthesis; osteointegration; sensitivity; specificity

Mesh:

Substances:

Year:  2017        PMID: 29366729     DOI: 10.1016/j.arth.2017.12.037

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  5 in total

1.  Comparison of radiographs, tomosynthesis and CT with metal artifact reduction for the detection of hip prosthetic loosening.

Authors:  Romain Gillet; Pedro Teixeira; Chloé Bonarelli; Henry Coudane; François Sirveaux; Mathias Louis; Alain Blum
Journal:  Eur Radiol       Date:  2018-09-07       Impact factor: 5.315

2.  Evaluation of peri-prosthetic radiolucent lines surrounding the cementless femoral stem using digital tomosynthesis with metal artifact reduction: a cadaveric study in comparison with radiography and computed tomography.

Authors:  Hao Tang; Xingjian Huang; Xiaoguang Cheng; Dejin Yang; Yong Huang; Yixin Zhou
Journal:  Quant Imaging Med Surg       Date:  2020-09

3.  Diagnosis of and Early Revision Surgery for Biological Fixation Failure Due to Proximal-Distal Mismatch of Proximally Coated Tapered Cementless Stem.

Authors:  Yasuhiro Homma; So Kawakita; Tomonori Baba; Taiji Watari; Kazuo Kaneko
Journal:  Arthroplast Today       Date:  2020-11-04

4.  What are the Complications of Three-dimensionally Printed, Custom-made, Integrative Hemipelvic Endoprostheses in Patients with Primary Malignancies Involving the Acetabulum, and What is the Function of These Patients?

Authors:  Jie Wang; Li Min; Minxun Lu; Yuqi Zhang; Yitian Wang; Yi Luo; Yong Zhou; Hong Duan; Chongqi Tu
Journal:  Clin Orthop Relat Res       Date:  2020-11       Impact factor: 4.755

5.  Radiographic assessment of radiolucent lines around a highly porous titanium cup (Tritanium) using digital tomosynthesis, after total hip arthroplasty.

Authors:  Kazuki Oishi; Yuji Yamamoto; Yoshifumi Harada; Ryo Inoue; Eiji Sasaki; Yasuyuki Ishibashi
Journal:  J Orthop Surg Res       Date:  2021-04-15       Impact factor: 2.359

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.