Aiguo Han1, Michael P Andre2, Lisa Deiranieh2, Elise Housman2, John W Erdman3, Rohit Loomba4, Claude B Sirlin5, William D O'Brien1. 1. Bioacoustics Research Laboratory, Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA. 2. Department of Radiology, University of California, San Diego, and San Diego VA Healthcare System, San Diego, California. 3. Department of Food Science and Human Nutrition, University of Illinois at Urbana-Champaign, Urbana, Illinois, USA. 4. Nonalcoholic Fatty Liver Disease Research Center, Division of Gastroenterology, University of California, San Diego, La Jolla, California, USA. 5. Department of Radiology, University of California, San Diego, La Jolla, California, USA.
Abstract
OBJECTIVES: To assess the repeatability and reproducibility of the ultrasonic attenuation coefficient (AC) and backscatter coefficient (BSC) measured in the livers of adults with known or suspected nonalcoholic fatty liver disease (NAFLD). METHODS: The Institutional Review Board approved this Health Insurance Portability and Accountability Act-compliant prospective study; informed consent was obtained. Forty-one research participants with known or suspected NAFLD were recruited and underwent same-day ultrasound examinations of the right liver lobe with a clinical scanner by a clinical sonographer. Each participant underwent 2 scanning trials, with participant repositioning between trials. Two transducers were used in each trial. For each transducer, machine settings were optimized by the sonographer but then kept constant while 3 data acquisitions were obtained from the liver without participant repositioning and then from an external calibrated phantom. Raw RF echo data were recorded. The AC and BSC were measured within 2.6 to 3.0 MHz from a user-defined hepatic field of interest from each acquisition. The repeatability and reproducibility were analyzed by random-effects models. RESULTS: The mean AC and log-transformed BSC (logBSC) were 0.94 dB/cm-MHz and -27.0 dB, respectively. Intraclass correlation coefficients were 0.88 to 0.94 for the AC and 0.87 to 0.95 for the logBSC acquired without participant repositioning. For between-trial repeated scans with participant repositioning, the intraclass correlation coefficients were 0.80 to 0.84 for the AC and 0.69 to 0.82 for the logBSC after averaging results from 3 within-trial images. The variability introduced by the transducer was less than the repeatability error. CONCLUSIONS: Hepatic AC and BSC measures using a reference phantom technique on a clinical scanner are repeatable and reproducible between transducers in adults with known or suspected NAFLD.
OBJECTIVES: To assess the repeatability and reproducibility of the ultrasonic attenuation coefficient (AC) and backscatter coefficient (BSC) measured in the livers of adults with known or suspected nonalcoholic fatty liver disease (NAFLD). METHODS: The Institutional Review Board approved this Health Insurance Portability and Accountability Act-compliant prospective study; informed consent was obtained. Forty-one research participants with known or suspected NAFLD were recruited and underwent same-day ultrasound examinations of the right liver lobe with a clinical scanner by a clinical sonographer. Each participant underwent 2 scanning trials, with participant repositioning between trials. Two transducers were used in each trial. For each transducer, machine settings were optimized by the sonographer but then kept constant while 3 data acquisitions were obtained from the liver without participant repositioning and then from an external calibrated phantom. Raw RF echo data were recorded. The AC and BSC were measured within 2.6 to 3.0 MHz from a user-defined hepatic field of interest from each acquisition. The repeatability and reproducibility were analyzed by random-effects models. RESULTS: The mean AC and log-transformed BSC (logBSC) were 0.94 dB/cm-MHz and -27.0 dB, respectively. Intraclass correlation coefficients were 0.88 to 0.94 for the AC and 0.87 to 0.95 for the logBSC acquired without participant repositioning. For between-trial repeated scans with participant repositioning, the intraclass correlation coefficients were 0.80 to 0.84 for the AC and 0.69 to 0.82 for the logBSC after averaging results from 3 within-trial images. The variability introduced by the transducer was less than the repeatability error. CONCLUSIONS: Hepatic AC and BSC measures using a reference phantom technique on a clinical scanner are repeatable and reproducible between transducers in adults with known or suspected NAFLD.
Authors: Rohit Loomba; Nicholas Schork; Chi-Hua Chen; Ricki Bettencourt; Ana Bhatt; Brandon Ang; Phirum Nguyen; Carolyn Hernandez; Lisa Richards; Joanie Salotti; Steven Lin; Ekihiro Seki; Karen E Nelson; Claude B Sirlin; David Brenner Journal: Gastroenterology Date: 2015-08-20 Impact factor: 22.682
Authors: Jeremy S Paige; Gregory S Bernstein; Elhamy Heba; Eduardo A C Costa; Marilia Fereirra; Tanya Wolfson; Anthony C Gamst; Mark A Valasek; Grace Y Lin; Aiguo Han; John W Erdman; William D O'Brien; Michael P Andre; Rohit Loomba; Claude B Sirlin Journal: AJR Am J Roentgenol Date: 2017-03-07 Impact factor: 3.959
Authors: X Chen; D Phillips; K Q Schwarz; J G Mottley; K J Parker Journal: IEEE Trans Ultrason Ferroelectr Freq Control Date: 1997 Impact factor: 2.725
Authors: Barbara L McFarlin; Jennifer Balash; Viksit Kumar; Timothy A Bigelow; Xavier Pombar; Jacques S Abramowicz; William D O'Brien Journal: Ultrasound Med Biol Date: 2015-05-23 Impact factor: 2.998
Authors: Aiguo Han; Michael P Andre; John W Erdman; Rohit Loomba; Claude B Sirlin; William D O'Brien Journal: IEEE Trans Ultrason Ferroelectr Freq Control Date: 2016-07-09 Impact factor: 2.725
Authors: Robert P Myers; Aaron Pollett; Richard Kirsch; Gilles Pomier-Layrargues; Melanie Beaton; Mark Levstik; Andres Duarte-Rojo; David Wong; Pam Crotty; Magdy Elkashab Journal: Liver Int Date: 2012-03-21 Impact factor: 5.828
Authors: David L Raunig; Lisa M McShane; Gene Pennello; Constantine Gatsonis; Paul L Carson; James T Voyvodic; Richard L Wahl; Brenda F Kurland; Adam J Schwarz; Mithat Gönen; Gudrun Zahlmann; Marina V Kondratovich; Kevin O'Donnell; Nicholas Petrick; Patricia E Cole; Brian Garra; Daniel C Sullivan Journal: Stat Methods Med Res Date: 2014-06-11 Impact factor: 3.021
Authors: Thuy-Anh Le; Joshua Chen; Christopher Changchien; Michael R Peterson; Yuko Kono; Heather Patton; Benjamin L Cohen; David Brenner; Claude Sirlin; Rohit Loomba Journal: Hepatology Date: 2012-07-02 Impact factor: 17.425
Authors: Aiguo Han; Yingzhen N Zhang; Andrew S Boehringer; Vivian Montes; Michael P Andre; John W Erdman; Rohit Loomba; Mark A Valasek; Claude B Sirlin; William D O'Brien Journal: Radiology Date: 2020-02-04 Impact factor: 11.105
Authors: Joe L Rowles; Aiguo Han; Rita J Miller; Jamie R Kelly; Catherine C Applegate; Matthew A Wallig; William D O'Brien; John W Erdman Journal: Nutr Res Date: 2018-12-14 Impact factor: 3.315
Authors: Aiguo Han; Yingzhen N Zhang; Andrew S Boehringer; Michael P Andre; John W Erdman; Rohit Loomba; Claude B Sirlin; William D O'Brien Journal: Eur Radiol Date: 2019-02-19 Impact factor: 5.315
Authors: Shi Chen; Barbara L McFarlin; Barbara T Meagher; Tara A Peters; Douglas G Simpson; William D O'Brien; Aiguo Han Journal: IEEE Trans Ultrason Ferroelectr Freq Control Date: 2019-06-14 Impact factor: 2.725
Authors: Jinho Jung; Aiguo Han; Egbert Madamba; Ricki Bettencourt; Rohan R Loomba; Andrew S Boehringer; Michael P Andre; John W Erdman; William D O'Brien; Kathryn J Fowler; Claude B Sirlin; Rohit Loomba Journal: Radiology Date: 2022-03-29 Impact factor: 29.146
Authors: Catherine N Steffel; Shahriar Salamat; Thomas D Cook; Stephanie M Wilbrand; Robert J Dempsey; Carol C Mitchell; Tomy Varghese Journal: Ultrasound Med Biol Date: 2020-04-11 Impact factor: 2.998
Authors: Aiguo Han; Yassin Labyed; Ethan Z Sy; Andrew S Boehringer; Michael P Andre; John W Erdman; Rohit Loomba; Claude B Sirlin; William D O'Brien Journal: Eur Radiol Date: 2018-06-04 Impact factor: 5.315
Authors: Aiguo Han; Michal Byra; Elhamy Heba; Michael P Andre; John W Erdman; Rohit Loomba; Claude B Sirlin; William D O'Brien Journal: Radiology Date: 2020-02-25 Impact factor: 29.146