Literature DB >> 29339890

Further Development of a Robotic-Assisted Transfer Device.

Jessica Burkman1,2, Garrett Grindle1,2, Hongwu Wang1,2, Annmarie Kelleher1,2, Rory A Cooper1,2.   

Abstract

Background: The task of performing transfers, such as from a wheelchair to a bed, has a high risk of injury to both the caregiver and the person being transferred. Although mechanical transfer devices can reduce these risks, these devices are not meant for use in the community and they still place strain on the caregiver when used. Purpose: The aim of this study is to describe feedback gathered from focus groups of potential users of the Robotic-Assisted Transfer Device (RATD) and describe design changes aimed at preparing the device for the next step in the development process. Method: The RATD was transferred to a newer electric-powered wheelchair (EPW), key components were redesigned, and the control program was updated to increase the safety of the device. Two focus groups, one consisting of people with disabilities and the other consisting of clinicians and caregivers, were conducted to gather feedback from potential users.
Results: Error checking, safety zones, a motor brake, and a new track helped increase the safety of the device. Sixty-three percent of the people with disabilities and 83% of caregivers surveyed said they would use the device. Conclusions: The results from the focus groups were positive and the design changes were successful, but more development is needed before the RATD can be marketed.

Entities:  

Keywords:  assistive technology; disability; wheelchair

Mesh:

Year:  2017        PMID: 29339890      PMCID: PMC5672881          DOI: 10.1310/sci2302-140

Source DB:  PubMed          Journal:  Top Spinal Cord Inj Rehabil        ISSN: 1082-0744


  12 in total

1.  Biomechanical analysis of peak and cumulative spinal loads during simulated patient-handling activities: a substudy of a randomized controlled trial to prevent lift and transfer injury of health care workers.

Authors:  D Daynard; A Yassi; J E Cooper; R Tate; R Norman; R Wells
Journal:  Appl Ergon       Date:  2001-06       Impact factor: 3.661

2.  Initial development of direct interaction for a transfer robotic Arm system for caregivers.

Authors:  Hervens Jeannis; Garrett G Grindle; Annmarie Kelleher; Hongwu Wang; Bambi Brewer; Rory Cooper
Journal:  IEEE Int Conf Rehabil Robot       Date:  2013-06

3.  A biomechanical assessment of floor and overhead lifts using one or two caregivers for patient transfers.

Authors:  Tilak Dutta; Pamela Jean Holliday; Susan Margaret Gorski; Mohammad Sadegh Baharvandy; Geoff Roy Fernie
Journal:  Appl Ergon       Date:  2011-08-27       Impact factor: 3.661

Review 4.  An expert review of the scientific literature on independent wheelchair transfers.

Authors:  Alicia Koontz; Maria Toro; Padmaja Kankipati; Megan Naber; Rory Cooper
Journal:  Disabil Rehabil Assist Technol       Date:  2011-05-18

5.  An evaluation of mechanical aids used within the NHS.

Authors:  T McGuire; J Moody; M Hanson
Journal:  Nurs Stand       Date:  1996-10-30

6.  Stability analysis of electrical powered wheelchair-mounted robotic-assisted transfer device.

Authors:  Hongwu Wang; Chung-Ying Tsai; Hervens Jeannis; Cheng-Shiu Chung; Annmarie Kelleher; Garrett G Grindle; Rory A Cooper
Journal:  J Rehabil Res Dev       Date:  2014

7.  Lumbar spine forces during manoeuvring of ceiling-based and floor-based patient transfer devices.

Authors:  W S Marras; G G Knapik; S Ferguson
Journal:  Ergonomics       Date:  2009-03       Impact factor: 2.778

Review 8.  A contextual-behavioral model of empowerment: case studies involving people with physical disabilities.

Authors:  S B Fawcett; G W White; F E Balcazar; Y Suarez-Balcazar; R M Mathews; A Paine-Andrews; T Seekins; J F Smith
Journal:  Am J Community Psychol       Date:  1994-08

9.  Evaluation of ceiling lifts: transfer time, patient comfort and staff perceptions.

Authors:  Hasanat Alamgir; Olivia Wei Li; Shicheng Yu; Erin Gorman; Catherine Fast; Catherine Kidd
Journal:  Injury       Date:  2009-05-31       Impact factor: 2.586

10.  Design and user evaluation of a wheelchair mounted robotic assisted transfer device.

Authors:  Garrett G Grindle; Hongwu Wang; Hervens Jeannis; Emily Teodorski; Rory A Cooper
Journal:  Biomed Res Int       Date:  2015-02-22       Impact factor: 3.411

View more
  2 in total

1.  Assessment of Usability and Task Load Demand Using a Robot-Assisted Transfer Device Compared With a Hoyer Advance for Dependent Wheelchair Transfers.

Authors:  Mark Greenhalgh; James Matthew Landis; Joshua Brown; Hailee Kulich; Sarah Bass; Saleh Alqahtani; Nikitha Deepak; Theresa Marie Cryzter; Garrett G Grindle; Alicia M Koontz; Rory A Cooper
Journal:  Am J Phys Med Rehabil       Date:  2019-08       Impact factor: 2.159

2.  Clinical and Ergonomic Comparison Between a Robotic Assisted Transfer Device and a Mobile Floor Lift During Caregiver-Assisted Wheelchair Transfers.

Authors:  Mark Greenhalgh; Eline Blaauw; Nikitha Deepak; Matthew St Laurent; Rosemarie Cooper; Roxanna Bendixen; Garrett G Grindle; Alicia M Koontz; Rory A Cooper
Journal:  Am J Phys Med Rehabil       Date:  2021-09-30       Impact factor: 3.412

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.