A biomechanical assessment of floor and overhead lifts using one or two caregivers for patient transfers.

Tilak Dutta1, Pamela Jean Holliday, Susan Margaret Gorski, Mohammad Sadegh Baharvandy, Geoff Roy Fernie.   

Abstract

This study investigated the differences in peak external hand forces and external moments generated at the L5/S1 joint of the low back due to maneuvering loaded floor-based and overhead-mounted patient lifting devices using one and two caregivers. Hand forces and external moments at the L5/S1 joint were estimated from ground reaction forces and motion capture data. Caregivers gave ratings of perceived exertion as well as their opinions regarding overhead vs. floor lifts. Use of overhead lifts resulted in significantly lower back loads than floor lifts. Two caregivers working together with a floor lift did not reduce loads on the primary caregiver compared to the single-caregiver case. In contrast, two-caregiver operation of an overhead lift did result in reduced loads compared to the single-caregiver case. Therefore, overhead lifts should be used whenever possible to reduce the risk of back injury to caregivers. The use of two caregivers does not compensate for the poorer performance of floor lifts.
Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21875699     DOI: 10.1016/j.apergo.2011.08.006

Source DB:  PubMed          Journal:  Appl Ergon        ISSN: 0003-6870            Impact factor:   3.661


  4 in total

1.  Clinical and Ergonomic Comparison Between a Robotic Assisted Transfer Device and a Mobile Floor Lift During Caregiver-Assisted Wheelchair Transfers.

Authors:  Mark Greenhalgh; Eline Blaauw; Nikitha Deepak; Matthew St Laurent; Rosemarie Cooper; Roxanna Bendixen; Garrett G Grindle; Alicia M Koontz; Rory A Cooper
Journal:  Am J Phys Med Rehabil       Date:  2021-09-30       Impact factor: 3.412

2.  Further Development of a Robotic-Assisted Transfer Device.

Authors:  Jessica Burkman; Garrett Grindle; Hongwu Wang; Annmarie Kelleher; Rory A Cooper
Journal:  Top Spinal Cord Inj Rehabil       Date:  2017

3.  People Lifting Patterns-A Reference Dataset for Practitioners.

Authors:  Konrad Kluwak; Ryszard Klempous; Zenon Chaczko; Jerzy W Rozenblit; Marek Kulbacki
Journal:  Sensors (Basel)       Date:  2021-04-30       Impact factor: 3.576

4.  Inertial Motion Capture-Based Estimation of L5/S1 Moments during Manual Materials Handling.

Authors:  Antoine Muller; Hakim Mecheri; Philippe Corbeil; André Plamondon; Xavier Robert-Lachaine
Journal:  Sensors (Basel)       Date:  2022-08-26       Impact factor: 3.847

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.