Hossam El-Rewaidy1, Maryam Nezafat1,2, Jihye Jang1,3, Shiro Nakamori1, Ahmed S Fahmy1,4, Reza Nezafat1. 1. Department of Medicine (Cardiovascular Division), Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts, USA. 2. Division of Imaging Sciences & Biomedical Engineering, King's College London, London, United Kingdom. 3. Department of Computer Science, Technical University of Munich, Munich, Germany. 4. Systems and Biomedical Engineering, Cairo University, Giza, Egypt.
Abstract
PURPOSE: Accurate reconstruction of myocardial T1 maps from a series of T1 -weighted images consists of cardiac motions induced from breathing and diaphragmatic drifts. We propose and evaluate a new framework based on active shape models to correct for motion in myocardial T1 maps. METHODS: Multiple appearance models were built at different inversion time intervals to model the blood-myocardium contrast and brightness changes during the longitudinal relaxation. Myocardial inner and outer borders were automatically segmented using the built models, and the extracted contours were used to register the T1 -weighted images. Data acquired from 210 patients using a free-breathing acquisition protocol were used to train and evaluate the proposed framework. Two independent readers evaluated the quality of the T1 maps before and after correction using a four-point score. The mean absolute distance and Dice index were used to validate the registration process. RESULTS: The testing data set from 180 patients at 5 short axial slices showed a significant decrease of mean absolute distance (from 3.3 ± 1.6 to 2.3 ± 0.8 mm, P < 0.001) and increase of Dice (from 0.89 ± 0.08 to 0.94 ± 0.4%, P < 0.001) before and after correction, respectively. The T1 map quality improved in 70 ± 0.3% of the motion-affected maps after correction. Motion-corrupted segments of the myocardium reduced from 21.8 to 8.5% (P < 0.001) after correction. CONCLUSION: The proposed method for nonrigid registration of T1 -weighted images allows T1 measurements in more myocardial segments by reducing motion-induced T1 estimation errors in myocardial segments. Magn Reson Med 80:780-791, 2018.
PURPOSE: Accurate reconstruction of myocardial T1 maps from a series of T1 -weighted images consists of cardiac motions induced from breathing and diaphragmatic drifts. We propose and evaluate a new framework based on active shape models to correct for motion in myocardial T1 maps. METHODS: Multiple appearance models were built at different inversion time intervals to model the blood-myocardium contrast and brightness changes during the longitudinal relaxation. Myocardial inner and outer borders were automatically segmented using the built models, and the extracted contours were used to register the T1 -weighted images. Data acquired from 210 patients using a free-breathing acquisition protocol were used to train and evaluate the proposed framework. Two independent readers evaluated the quality of the T1 maps before and after correction using a four-point score. The mean absolute distance and Dice index were used to validate the registration process. RESULTS: The testing data set from 180 patients at 5 short axial slices showed a significant decrease of mean absolute distance (from 3.3 ± 1.6 to 2.3 ± 0.8 mm, P < 0.001) and increase of Dice (from 0.89 ± 0.08 to 0.94 ± 0.4%, P < 0.001) before and after correction, respectively. The T1 map quality improved in 70 ± 0.3% of the motion-affected maps after correction. Motion-corrupted segments of the myocardium reduced from 21.8 to 8.5% (P < 0.001) after correction. CONCLUSION: The proposed method for nonrigid registration of T1 -weighted images allows T1 measurements in more myocardial segments by reducing motion-induced T1 estimation errors in myocardial segments. Magn Reson Med 80:780-791, 2018.
Authors: Hui Xue; Saurabh Shah; Andreas Greiser; Christoph Guetter; Arne Littmann; Marie-Pierre Jolly; Andrew E Arai; Sven Zuehlsdorff; Jens Guehring; Peter Kellman Journal: Magn Reson Med Date: 2011-08-29 Impact factor: 4.668
Authors: Leah Iles; Heinz Pfluger; Arintaya Phrommintikul; Joshi Cherayath; Pelin Aksit; Sandeep N Gupta; David M Kaye; Andrew J Taylor Journal: J Am Coll Cardiol Date: 2008-11-04 Impact factor: 24.094
Authors: Stefan K Piechnik; Vanessa M Ferreira; Erica Dall'Armellina; Lowri E Cochlin; Andreas Greiser; Stefan Neubauer; Matthew D Robson Journal: J Cardiovasc Magn Reson Date: 2010-11-19 Impact factor: 5.364
Authors: Philippe Germain; Soraya El Ghannudi; Mi-Young Jeung; Patrick Ohlmann; Eric Epailly; Catherine Roy; Afshin Gangi Journal: Clin Med Insights Cardiol Date: 2014-12-01