Metal artifact reduction in CT, a phantom study: subjective and objective evaluation of four commercial metal artifact reduction algorithms when used on three different orthopedic metal implants.

Kirsten Bolstad1, Silje Flatabø1, Daniel Aadnevik1, Ingvild Dalehaug1, Nils Vetti2.   

Abstract

Background Metal implants may introduce severe artifacts in computed tomography (CT) images. Over the last few years dedicated algorithms have been developed in order to reduce metal artifacts in CT images. Purpose To investigate and compare metal artifact reduction algorithms (MARs) from four different CT vendors when imaging three different orthopedic metal implants. Material and Methods Three clinical metal implants were attached to the leg of an anthropomorphic phantom: cobalt-chrome; stainless steel; and titanium. Four commercial MARs were investigated: SmartMAR (GE); O-MAR (Philips); iMAR (Siemens); and SEMAR (Toshiba). The images were evaluated subjectively by three observers and analyzed objectively by calculating the fraction of pixels with CT number above 500 HU in a region of interest around the metal. The average CT number and image noise were also measured. Results Both subjective evaluation and objective analysis showed that MARs reduced metal artifacts and improved the image quality for CT images containing metal implants of steel and cobalt-chrome. When using MARs on titanium, all MARs introduced new visible artifacts. Conclusion The effect of MARs varied between CT vendors and different metal implants used in orthopedic surgery. Both in subjective evaluation and objective analysis the effect of applying MARs was most obvious on steel and cobalt-chrome implants when using SEMAR from Toshiba followed by SmartMAR from GE. However, MARs may also introduce new image artifacts especially when used on titanium implants. Therefore, it is important to reconstruct all CT images containing metal with and without MARs.

Entities:  

Keywords:  Tomography; X-ray computed; algorithms; artifacts; diagnostic imaging; metals; orthopedic fixation devices; phantoms

Mesh:

Substances:

Year:  2018        PMID: 29310445     DOI: 10.1177/0284185117751278

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  11 in total

1.  Metal Artifact Reduction in Head CT Performed for Patients with Deep Brain Stimulation Devices: Effectiveness of a Single-Energy Metal Artifact Reduction Algorithm.

Authors:  Y Nagayama; S Tanoue; S Oda; D Sakabe; T Emoto; M Kidoh; H Uetani; A Sasao; T Nakaura; O Ikeda; K Yamada; Y Yamashita
Journal:  AJNR Am J Neuroradiol       Date:  2019-12-26       Impact factor: 3.825

2.  Metal implants on abdominal CT: does split-filter dual-energy CT provide additional value over iterative metal artifact reduction?

Authors:  Hildegard M Wichtmann; Kai R Laukamp; Sebastian Manneck; Konrad Appelt; Bram Stieltjes; Daniel T Boll; Matthias R Benz; Markus M Obmann
Journal:  Abdom Radiol (NY)       Date:  2022-09-30

3.  Metal artifacts in patients with large dental implants and bridges: combination of metal artifact reduction algorithms and virtual monoenergetic images provides an approach to handle even strongest artifacts.

Authors:  Kai Roman Laukamp; David Zopfs; Simon Lennartz; Lenhard Pennig; David Maintz; Jan Borggrefe; Nils Große Hokamp
Journal:  Eur Radiol       Date:  2019-01-16       Impact factor: 5.315

4.  Comparison of quantitative measurements of four manufacturer's metal artifact reduction techniques for CT imaging with a self-made acrylic phantom.

Authors:  Ryan Chou; Hung-Yi Chi; Yi-Hung Lin; Liu-Kuo Ying; Yu-Ju Chao; Cheng-Hsun Lin
Journal:  Technol Health Care       Date:  2020       Impact factor: 1.285

5.  Methodology for Measurement of in vivo Tibiotalar Kinematics After Total Ankle Replacement Using Dual Fluoroscopy.

Authors:  Dylan J Blair; Alexej Barg; K Bo Foreman; Andrew E Anderson; Amy L Lenz
Journal:  Front Bioeng Biotechnol       Date:  2020-05-05

6.  CT metal artifact reduction algorithms: Toward a framework for objective performance assessment.

Authors:  J Y Vaishnav; B Ghammraoui; M Leifer; R Zeng; L Jiang; K J Myers
Journal:  Med Phys       Date:  2020-06-05       Impact factor: 4.071

7.  CT radiation dose reduction in patients with total hip arthroplasties using model-based iterative reconstruction and orthopaedic metal artefact reduction.

Authors:  Ruud H H Wellenberg; Jochen A C van Osch; Henk J Boelhouwers; Mireille A Edens; Geert J Streekstra; Harmen B Ettema; Martijn F Boomsma
Journal:  Skeletal Radiol       Date:  2019-04-24       Impact factor: 2.199

8.  Determination of Programmable Shunt Setting Using CT: Feasibility Study.

Authors:  Einat Slonimsky; Brad Zacharia; Alex Mamourian
Journal:  Cureus       Date:  2021-11-22

9.  Evaluation of VMAT Planning Strategies for Prostate Patients with Bilateral Hip Prosthesis.

Authors:  David To; Ilma Xhaferllari; Manju Liu; Jian Liang; Cory Knill; Sirisha Nandalur; Gary Gustafson; Danielle Lack
Journal:  Technol Cancer Res Treat       Date:  2021 Jan-Dec

Review 10.  Improving radiation physics, tumor visualisation, and treatment quantification in radiotherapy with spectral or dual-energy CT.

Authors:  Matthijs Ferdinand Kruis
Journal:  J Appl Clin Med Phys       Date:  2021-11-07       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.