Literature DB >> 2930070

Total respiratory resistance and reactance as a measurement of response to bronchial challenge with histamine.

J A van Noord1, J Clement, K P van de Woestijne, M Demedts.   

Abstract

The potential of the forced oscillation technique to detect the airway response on histamine bronchial challenge tests was compared with that of FEV1 and plethysmographic SGaw. In 53 subjects with a history of episodic wheezing and a normal baseline airway resistance, we carried out bronchial challenges with successively doubling concentrations of histamine until FEV1 had dropped by 15% or more or a concentration of 16 mg/ml histamine was reached. For the baseline values, a mean within-subject coefficient of variation was found of 2.8% for FEV1, 7.4% for SGaw, 8.7% for the oscillatory respiratory conductance at 6 Hz (1/Rrs6), and 7.7% for the mean oscillatory respiratory conductance (between 2 and 26 Hz) (1/Rrs). The latter coefficients allow the calculation of the following threshold values: PD15FEV1, PD40SGaw, PD47 1/Rrs6, and PD42 1/Rrs. The probability of exceeding these levels by chance is virtually zero. Histamine challenge caused significant absolute changes in Rrs at 6 Hz (Rrs6), in mean level of Rrs and of respiratory reactance (Xrs), in slope of Rrs and Xrs versus frequency, and in mean curvature of Rrs-frequency curve. A multivariate analysis of the differences between prechallenge and postchallenge values showed that the parameters with the best sensitivity to detect the effect of histamine were, in decreasing order: the relative change of SGaw, of 1/Rrs6, of 1/Rrs, of FEV1, of FVC, and of 1/Vtg, followed by the absolute change of Xrs and of the average slope of the Rrs-frequency relationship.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2930070     DOI: 10.1164/ajrccm/139.4.921

Source DB:  PubMed          Journal:  Am Rev Respir Dis        ISSN: 0003-0805


  6 in total

Review 1.  Respiratory input impedance measurement: forced oscillation methods.

Authors:  D MacLeod; M Birch
Journal:  Med Biol Eng Comput       Date:  2001-09       Impact factor: 2.602

2.  Chronic cough and dyspnea in ice hockey players after an acute exposure to combustion products of a faulty ice resurfacer.

Authors:  Erika S Kahan; Ubaldo J Martin; Steve Spungen; David Ciccolella; Gerard J Criner
Journal:  Lung       Date:  2007-02-09       Impact factor: 2.584

3.  Relating small airways to asthma control by using impulse oscillometry in children.

Authors:  Yixin Shi; Anna S Aledia; Ahramahzd V Tatavoosian; Shruthi Vijayalakshmi; Stanley P Galant; Steven C George
Journal:  J Allergy Clin Immunol       Date:  2011-12-17       Impact factor: 10.793

4.  Forced oscillation technique and spirometry in cold air provocation tests.

Authors:  G J Wesseling; I M Vanderhoven-Augustin; E F Wouters
Journal:  Thorax       Date:  1993-03       Impact factor: 9.139

5.  Effects of hypercapnia and hypocapnia on respiratory resistance in normal and asthmatic subjects.

Authors:  F J van den Elshout; C L van Herwaarden; H T Folgering
Journal:  Thorax       Date:  1991-01       Impact factor: 9.139

6.  Clinical applications of forced oscillation techniques (FOT) in patients with bronchial asthma.

Authors:  C W Kim; J S Kim; J W Park; C S Hong
Journal:  Korean J Intern Med       Date:  2001-06       Impact factor: 2.884

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.