Forced oscillation technique and spirometry in cold air provocation tests.

G J Wesseling1, I M Vanderhoven-Augustin, E F Wouters.   

Abstract

BACKGROUND: Impedance measurements by the forced pseudo random noise oscillation technique can be used to study the mechanical characteristics of the respiratory system. The objective of this study was to analyse the changes in impedance to a cold air provocation test in patients with asthma, and to correlate these changes with those in the forced expiratory volume in one second (FEV1).
METHODS: The response to isocapnic hyperventilation with cold air was assessed by respiratory impedance measurements and spirometry in 60 patients with bronchial asthma in whom the provocative dose of histamine resulting in a 20% fall in FEV1 (PD20) was < or = 8 mumol.
RESULTS: Cold air provocation resulted in a mean(SD) fall in FEV1 from 3.75(0.85) litres to 3.10(0.90) litres. The mean(SD) decrease in FEV1 as a percentage of predicted was 15.4(3.8)%. The oscillatory resistance at 8 Hz increased from a mean(SD) of 0.367(0.108) kPa/l/s to 0.613(0.213) kPa/l/s and at 28 Hz the resistance increased from 0.348(0.089) to 0.403(0.099) kPa/l/s. Frequency dependence of resistance became significantly more negative. The reactance at 8 Hz decreased from a mean(SD) of -0.035 (0.041) kPa/l/s to -0.234(0.199) kPa/l/s, and the resonant frequency increased from 12.5(4.9) Hz to 25.7(9.1) Hz. Significant correlations were calculated between the decrease in FEV1 and changes in the various impedance parameters, especially between the decrease in FEV1 and the increase in resistance at 8 Hz (r = -0.66), and the decrease in FEV1 and the increase in the resonant frequency (r = -0.63).
CONCLUSION: Cold air provocation in asthmatic subjects results in changes in the impedance of the respiratory system that correlate well with the changes in FEV1. These changes in impedance reflect ventilatory inhomogeneities in the peripheral compartment of the bronchial tree. These observations show the value of this technique in the evaluation of induced bronchoconstriction, as both a quantitative and a qualitative analysis of the response is possible.

Entities:  

Mesh:

Year:  1993        PMID: 8497825      PMCID: PMC464363          DOI: 10.1136/thx.48.3.254

Source DB:  PubMed          Journal:  Thorax        ISSN: 0040-6376            Impact factor:   9.139


  38 in total

1.  Use of an impedance meter for measuring airways responsiveness to histamine.

Authors:  P D Snashall; S Parker; P Ten Haave; D Simmons; M I Noble
Journal:  Chest       Date:  1991-05       Impact factor: 9.410

2.  Respiratory acoustical impedance: a new technique to measure airway response during bronchial inhalation challenges.

Authors:  F Feihl; M Badan; F Depeursinge; C Depeursinge; P Leuenberger; A Pécoud; C Perret
Journal:  Ann Allergy       Date:  1988-10

3.  Comparison of the dose-response curves obtained by forced oscillation and plethysmography during carbachol inhalation.

Authors:  T Chinet; G Pelle; I Macquin-Mavier; H Lorino; A Harf
Journal:  Eur Respir J       Date:  1988-07       Impact factor: 16.671

4.  Density dependence of respiratory input impedance re-evaluated with a head generator minimizing upper airway shunt.

Authors:  M Rotger; R Peslin; D Navajas; C Gallina; C Duvivier
Journal:  Eur Respir J       Date:  1988-05       Impact factor: 16.671

5.  Total resistance and reactance in patients with respiratory complaints with and without airways obstruction.

Authors:  J Clément; F J Làndsér; K P Van de Woestijne
Journal:  Chest       Date:  1983-02       Impact factor: 9.410

6.  Mechanical properties of lungs and chest wall during spontaneous breathing.

Authors:  J Nagels; F J Làndsér; L van der Linden; J Clément; K P Van de Woestijne
Journal:  J Appl Physiol Respir Environ Exerc Physiol       Date:  1980-09

7.  Respiratory impedance in normal humans: effects of bronchodilatation and bronchoconstriction.

Authors:  J C Manço; R E Hyatt; J R Rodarte
Journal:  Mayo Clin Proc       Date:  1987-06       Impact factor: 7.616

8.  Histamine challenge test in children using forced oscillation to measure total respiratory resistance.

Authors:  P Lebecque; S Spier; J G Lapierre; A Lamarre; R Zinman; A L Coates
Journal:  Chest       Date:  1987-08       Impact factor: 9.410

9.  Density and frequency dependence of resistance in early airway obstruction.

Authors:  L Brochard; G Pelle; J de Palmas; P Brochard; A Carre; H Lorino; A Harf
Journal:  Am Rev Respir Dis       Date:  1987-03

10.  Upper airway artifact in respiratory impedance measurements.

Authors:  R Peslin; C Duvivier; C Gallina; P Cervantes
Journal:  Am Rev Respir Dis       Date:  1985-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.