| Literature DB >> 11590906 |
C W Kim1, J S Kim, J W Park, C S Hong.
Abstract
BACKGROUND: Forced oscillation technique (FOT) is a method to characterize the mechanical properties of the respiratory system over a wide range of frequencies. Its most important advantage is to require minimal cooperation from the subject. This study was performed to evaluate the usefulness of the FOT applications in patients with bronchial asthma by estimating the associations between asthma severity and FOT parameters, and the relationships between FOT and spirometry parameters.Entities:
Mesh:
Year: 2001 PMID: 11590906 PMCID: PMC4531717 DOI: 10.3904/kjim.2001.16.2.80
Source DB: PubMed Journal: Korean J Intern Med ISSN: 1226-3303 Impact factor: 2.884
Clinical Characteristics of Patients
| Asthma severity
| |||
|---|---|---|---|
| Mild (n=111) | Moderate (n=78) | Severe (n=27) | |
| M/F | 61/50 | 32/46 | 9/18 |
| Age (yr) | 44.1±13.8 | 47.5±14.3 | 50.7±14.8 |
| Height (cm) | 164.8±8.2 | 161.5±7.6 | 160.2±8.1 |
| Weight (kg) | 63.9±9.1 | 62.5±10.5 | 59.8±9.4 |
| Sputum eosinophil (%) | 32.8±33.7 | 37.8±35.6 | 23.8±28.9 |
| Total IgE (U/mL) | 588.8±11.2 | 741.5±8.3 | 501.0±10.0 |
| M-PC20 (mg/mL) | 4.3±5.8 | 2.0±4.4 | 1.2±5.1 |
| PEFR (pred %) | 88.7±11.9 | 80.1±12.1 | 61.9±17.1 |
| FEV1 (pred %) | 98.1±16.3 | 83.2±15.3 | 57.6±20.0 |
| FEV1/VC (pred %) | 76.1±10.8 | 68.8±12.2 | 59.9±13.9 |
| MMEF (pred %) | 65.9±24.4 | 47.9±28.1 | 26.6±16.6 |
p<0.05: between each group.
Total IgE, M-PC20: geometric mean.
Comparison of FOT parameters according to asthma severity
| Asthma severity
| |||
|---|---|---|---|
| Mild (n=111) | Moderate (n=78) | Severe (n=27) | |
| Resonant frequency (Fres, Hz) | 16.1±4.7 | 18.1±5.8 | 24.0±6.9 |
| Impedance (Zrs, pred %) | 115.6±53.2 | 137.2±61.4 | 191.9±90.5 |
| Resistance at 5 Hz (R5Hz, pred %) | 108.1±49.9 | 130.1±59.7 | 171.5±78.2 |
| Resistance at 20 Hz (R20Hz, pred %) | 90.3±34.5 | 100.6±37.3 | 112.8±42.1 |
| Resistance at 35 Hz (R35Hz, pred %) | 42.4±4.0 | 47.7±5.4 | 51.0±9.8 |
| R5Hz – R20Hz (hPa/l/s) | 1.2±1.1 | 2.4±1.1 | 3.3±2.1 |
p<0.05: between each group.
p<0.05: between mild and severe group.
R5Hz–R20Hz: resistance difference at 5 Hz and 20 Hz (R5Hz–R20Hz).
Figure 1.Comparisons of FOT parameters according to asthma severity. Impedance (Zrs), resistance at 5 Hz and 20 Hz are described as % predicted value. Values of resonant frequency (Fres) are marked at the top of each bar.
Figure 2.Resistance difference at 5 Hz and 20 Hz. Resistance is increased according to asthma severity both at 5 Hz and at 20 Hz (a). There is significant difference of resistance difference at 5 Hz and 20 Hz between each group (b).
Figure 3.Correlation between FEV1 and impedance (a), resonant frequency (b), resistance at 5 Hz (c), and resistance at 20 Hz (d). Each correlation shows statistically significant relationship (p<0.05).
Correlation between FOT and Spirometry Parameters
| FEV1 (n=216) | MMEF | |
|---|---|---|
| Impedance (Zrs) | −0.49 | −0.34 |
| Resonant frequency (Fres) | −0.55 | −0.37 |
| Resistance at 5 Hz (R5Hz) | −0.48 | −0.35 |
| Resistance at 20 Hz (R20Hz) | −0.41 | −0.36 |
| Resistance at 35 Hz (R35Hz) | −0.35 | −0.32 |
p <0.05
measured for subjects with normal pulmonary function (FEV1≥80%).
Reproducibility of FOT Parameters in Subjects with no Severity Change
| Correlation coefficient | p-value | |
|---|---|---|
| FEV1 (L) | 0.79 | < 0.01 |
| Impedance (Zrs, hPa/l/s) | 0.49 | < 0.05 |
| Resonant frequency (Fres, Hz) | 0.47 | < 0.05 |
| Resistance at 5 Hz (R5Hz, hPa/l/s) | 0.78 | < 0.01 |
| Resistance at 20 Hz (R20Hz, hPa/l/s) | 0.65 | < 0.01 |
| Resistance at 35 Hz (R35Hz, hPa/l/s) | 0.81 | < 0.01 |
| Reactance at 5 Hz (X5Hz, hPa/l/s) | 0.18 | > 0.05 |
n=20, mean time interval of repeated test: 6 months.