Literature DB >> 29294311

Implantable Collamer Lens Sizing Method Based on Swept-Source Anterior Segment Optical Coherence Tomography.

Tomoaki Nakamura1, Naoki Isogai2, Takashi Kojima3, Yoko Yoshida2, Yasuo Sugiyama2.   

Abstract

PURPOSE: To develop and evaluate the accuracy of a size-determination formula using anterior segment optical coherence tomography (AS-OCT) parameters.
DESIGN: Interventional case series.
METHODS: This study included 46 eyes of 23 patients with implantable collamer lens (ICL). Preoperatively, the anterior segment parameters were measured using high-frequency ultrasound biomicroscopy and AS-OCT. Three months postoperatively, the vaults were measured and the optimal ICL size was calculated using a previously published method. Stepwise multiple regression analysis was performed using the optimal ICL size as a dependent variable; the NK-formula was obtained. Thereafter, 35 eyes of 18 patients were implanted with ICL after the size was calculated using the NK-formula. Vaults measured at 3 months postoperatively were used to evaluate the accuracy of the NK-formula.
RESULTS: The distance between scleral spurs (ACW) and crystalline lens rise (CLR) were selected as significant parameters for the regression model (R2 = 0.68, P < .05). There were 25 (71%), 8 (23%), and 2 (6%) eyes in the moderate, high, and low vault categories, respectively. Using the STAAR nomogram for ICL sizing, 24 eyes (69%) were fitted in the moderate vault. The mean absolute error of the predicted vault was significantly lower with the NK-formula (0.190 ± 0.129 mm) than with the STAAR nomogram (0.331 ± 0.235 mm, P = .002, paired t test).
CONCLUSION: AS-OCT is useful for ICL size determination, because it calculates the anterior segment parameters using automatic analysis. The NK-formula shows higher accuracy for predicting vault than the STAAR nomogram.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2017        PMID: 29294311     DOI: 10.1016/j.ajo.2017.12.015

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  21 in total

1.  Repeatability and agreement of two anterior segment OCT in myopic patients before implantable collamer lenses implantation.

Authors:  Xi-Fang Zhang; Meng Li; Yan Shi; Xiu-Hua Wan; Huai-Zhou Wang
Journal:  Int J Ophthalmol       Date:  2020-04-18       Impact factor: 1.779

2.  Comparison of Vault Measurements Using a Swept-Source OCT-Based Optical Biometer and Anterior Segment OCT.

Authors:  Yali Du; Chuang Jin; Shengjie Yin; Geng Wang; Qian Ma; Yuancun Li; Binyao Chen; Hongxi Wang; Kunliang Qiu; Mingzhi Zhang
Journal:  Front Med (Lausanne)       Date:  2022-06-23

3.  Inter-eye and postoperative prediction of vault after implantation of EVO + Visian phakic implantable collamer lens.

Authors:  Elena Martínez-Plaza; Alberto López-Miguel; Alberto López-de la Rosa; Miguel J Maldonado
Journal:  Int Ophthalmol       Date:  2022-10-19       Impact factor: 2.029

4.  Angle-to-angle and spur-to-spur distance analysis with high-resolution optical coherence tomography.

Authors:  Robert Montés-Micó; Pedro Tañá-Rivero; Salvador Aguilar-Córcoles; María Ruiz-Santos; María Dolores Rodríguez-Carrillo; Ramón Ruiz-Mesa
Journal:  Eye Vis (Lond)       Date:  2020-08-16

5.  Inter-Eye Vault Differences of Implantable Collamer Lens Measured Using Anterior Segment Optical Coherence Tomography.

Authors:  Santiago Cerpa Manito; Angel Sánchez Trancón; Oscar Torrado Sierra; António M G Baptista; Pedro Miguel Serra
Journal:  Clin Ophthalmol       Date:  2020-10-29

6.  Short-term changes in and preoperative factors affecting vaulting after posterior chamber phakic Implantable Collamer Lens implantation.

Authors:  Qiu-Jian Zhu; Wen-Jing Chen; Wei-Jian Zhu; Hai-Xiang Xiao; Man-Hui Zhu; Lie Ma; You Yuan; E Song
Journal:  BMC Ophthalmol       Date:  2021-05-06       Impact factor: 2.209

7.  Phakic intraocular lens: Getting the right size.

Authors:  Kalyaani Deshpande; Rushad Shroff; Partha Biswas; Kamal Kapur; Naren Shetty; Ann Sarah Koshy; Pooja Khamar
Journal:  Indian J Ophthalmol       Date:  2020-12       Impact factor: 1.848

8.  Lens-vault analysis and its correlation with other biometric parameters using swept-source OCT.

Authors:  Pedro Tañá-Rivero; Ramón Ruiz-Mesa; Salvador Aguilar-Córcoles; Cristina Tello-Elordi; María Ramos-Alzamora; Robert Montés-Micó
Journal:  J Optom       Date:  2021-11-01

9.  Prediction of anterior chamber volume after implantation of posterior chamber phakic intraocular lens.

Authors:  Yuki Takagi; Takashi Kojima; Tomoya Nishida; Tomoaki Nakamura; Kazuo Ichikawa
Journal:  PLoS One       Date:  2020-11-16       Impact factor: 3.240

10.  Development of a Web-Based Ensemble Machine Learning Application to Select the Optimal Size of Posterior Chamber Phakic Intraocular Lens.

Authors:  Eun Min Kang; Ik Hee Ryu; Geunyoung Lee; Jin Kuk Kim; In Sik Lee; Ga Hee Jeon; Hojin Song; Kazutaka Kamiya; Tae Keun Yoo
Journal:  Transl Vis Sci Technol       Date:  2021-05-03       Impact factor: 3.283

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.