Literature DB >> 2928377

Ferrous sulphate gels for determination of absorbed dose distributions using MRI technique: basic studies.

L E Olsson1, S Petersson, L Ahlgren, S Mattsson.   

Abstract

Two gels have been found to be suitable to load with ferrous sulphate solution. In these soft tissue equivalent phantoms, the absorbed dose distribution can be measured after irradiation in clinically used MR imaging equipment. The present studies were carried out using a 0.25 T NMR analyser without imaging properties. A ferrous sulphate solution, 0.05 M with respect to sulphuric acid, can be gelled with 4% gelatin to give a dosemeter which has a response which is linearly correlated (r = 0.998) with the absorbed dose in the interval 0-40 Gy. Ferrous sulphate solution can also be gelled with 1% agarose, but this gel has to be purged with oxygen to obtain a linear relationship (r = 0.997) in the same absorbed dose interval. The ferrous sulphate loaded gels have a sensitivity which is a factor of 2.2 or 4.0 times higher for gelatin and agarose, respectively, than the ordinary dosemeter solution. Because the standard deviation of background measurements is higher for the gels than for the dosemeter solution, the minimum detectable absorbed dose is about the same, or 1.0 Gy, for the two gels and the dosemeter solution. The sensitivity of the ferrous sulphate loaded gels shows no dependence on dose rate if the mean dose rate and the absorbed dose per pulse are within the limits normally used by accelerators for radiotherapy.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2928377     DOI: 10.1088/0031-9155/34/1/004

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  [The verification of optimized 3D-dosage distributions with an MR Fricke gel].

Authors:  J Scherer; L Bogner; M Herbst; A Müller-Broich
Journal:  Strahlenther Onkol       Date:  1997-01       Impact factor: 3.621

2.  Optical scanner for 3D radiotherapy polymer gel dosimetry.

Authors:  Piotr Sobotka; Marek Kozicki; Piotr Maras; Ł Boniecki; K Kacperski; A W Domański
Journal:  Acta Phys Pol A       Date:  2012-11       Impact factor: 0.577

3.  Radiological properties of nanocomposite Fricke gel dosimeters for heavy ion beams.

Authors:  Takuya Maeyama; Nobuhisa Fukunishi; Kenichi L Ishikawa; Kazuaki Fukasaku; Shigekazu Fukuda
Journal:  J Radiat Res       Date:  2016-03-10       Impact factor: 2.724

Review 4.  Three-dimensional radiation dosimetry using polymer gel and solid radiochromic polymer: From basics to clinical applications.

Authors:  Yoichi Watanabe; Leighton Warmington; N Gopishankar
Journal:  World J Radiol       Date:  2017-03-28

5.  Determination of paramagnetic ferrous gel sensitivity in low energy x-ray beam produced by a miniature accelerator.

Authors:  Yassir Ben Ahmed; Jérémy Coulaud; Soléakhena Ken; Laure Parent
Journal:  PLoS One       Date:  2020-05-04       Impact factor: 3.240

6.  Study of the Optimal Composition and Storage Conditions of the Fricke-XO-Pluronic F-127 Radiochromic Dosimeter.

Authors:  Michał Piotrowski; Piotr Maras; Sławomir Kadłubowski; Marek Kozicki
Journal:  Materials (Basel)       Date:  2022-01-27       Impact factor: 3.623

Review 7.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19

8.  Prevention of transfusion-associated graft-versus-host disease by irradiation: technical aspect of a new ferrous sulphate dosimetric system.

Authors:  Lucas Sacchini Del Lama; Evamberto Garcia de Góes; Paulo César Dias Petchevist; Edson Lara Moretto; José Carlos Borges; Dimas Tadeu Covas; Adelaide de Almeida
Journal:  PLoS One       Date:  2013-06-07       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.