A direct comparison of water calorimetry and Fricke dosimetry.

C K Ross1, N V Klassen, K R Shortt, G D Smith.   

Abstract

Considerable effort has been devoted to measuring the absorbed dose to water using water calorimetry. Most of these efforts have been hampered by a lack of adequate knowledge of the heat defect of water. We argue that there is now sufficient information to establish with considerable confidence the heat defect of high-purity water containing various dissolved gases. For the present work we used water saturated with a 50/50 mixture of H2 and O2 gases, for which the heat defect is calculated to be -2.1%. As a test of this assignment, we have compared the absorbed dose to water as measured using water calorimetry with that obtained from Fricke dosimetry. The water calorimeter consisted of a small sealed vessel containing 100 ml of stirred water saturated with a 50/50 mixture of H2 and O2 gases. It was irradiated with 20 MV x-rays at a dose rate of about 0.4 Gy s-1. The same vessel was then filled with Fricke dosemeter solution, and irradiated under identical conditions. Our Fricke dosimetry is based on the Svensson and Brahme value of epsilon G (3.515 x 10(-3) 1 cm-1 J-1) and agrees to within 0.2% with the dose to water for 60Co gamma-rays obtained via graphite calorimetry. We find that for 20 MV x-rays, the dose to water determined by water calorimetry is 1.006 +/- 0.004 times the dose determined by Fricke dosimetry. Within 0.6(+/- 0.4)%, this result supports the calculated heat defect of -2.1% for water saturated with a 50/50 mixture of H2 and O2 gases.

Entities:  

Mesh:

Year:  1989        PMID: 2928376     DOI: 10.1088/0031-9155/34/1/003

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  A simulation study of ionizing radiation acoustic imaging (iRAI) as a real-time dosimetric technique for ultra-high dose rate radiotherapy (UHDR-RT).

Authors:  Noora H Ba Sunbul; Wei Zhang; Ibrahim Oraiqat; Dale W Litzenberg; Kwok L Lam; Kyle Cuneo; Jean M Moran; Paul L Carson; Xueding Wang; Shaun D Clarke; Martha M Matuszak; Sara A Pozzi; Issam El Naqa
Journal:  Med Phys       Date:  2021-09-08       Impact factor: 4.071

2.  Water Calorimetry: The Heat Defect.

Authors:  Norman V Klassen; Carl K Ross
Journal:  J Res Natl Inst Stand Technol       Date:  1997 Jan-Feb

3.  LET-Dependent Intertrack Yields in Proton Irradiation at Ultra-High Dose Rates Relevant for FLASH Therapy.

Authors:  J Ramos-Méndez; N Domínguez-Kondo; J Schuemann; A McNamara; E Moreno-Barbosa; Bruce Faddegon
Journal:  Radiat Res       Date:  2020-10-02       Impact factor: 2.841

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.