Literature DB >> 29260301

Regional Hounsfield unit measurement of screw trajectory for predicting pedicle screw fixation using cortical bone trajectory: a retrospective cohort study.

Keitaro Matsukawa1, Yuichiro Abe2, Yoshihide Yanai3, Yoshiyuki Yato3.   

Abstract

BACKGROUND: The sufficiency of screw anchoring is a critical factor for achieving successful spinal fusion; however, no reliable method for predicting pedicle screw fixation has been established. Recently, Hounsfield units (HU) obtained from computed tomography (CT) was developed as a new reliable tool to determine the bone quality. The purpose of the present study was to demonstrate the utility of regional HU measurement of the screw trajectory to predict the primary and long-term fixation strength of pedicle screws.
METHOD: The insertional torque of pedicle screws using the cortical bone trajectory technique was measured intraoperatively in 92 consecutive patients who underwent single-level posterior lumbar interbody fusion. The cylindrical area of each screw was plotted on the preoperative CT image by precisely confirming the screw position, and the screw trajectory was measured in HU. First, three parameters: the bone mineral density (BMD) of the femoral neck and lumbar vertebrae, and regional HU values of the screw trajectory, were correlated with the insertional torque and compared among three groups. Next, pedicle screw loosening was evaluated by postoperative CT obtained 12 months after surgery, and clinical and imaging data were analyzed to assess whether regional HU values could be used as a predictor of screw loosening.
RESULTS: Regional HU values of the screw trajectory (r = 0.75, p < 0.001) had stronger correlation with the insertional torque than the femoral BMD (r = 0.59, p < 0.001) and lumbar BMD (r = 0.55, p < 0.001). The incidence of screw loosening was 4.6% (16/351). Multivariate logistic regression analysis revealed that regional HU value (odds ratio = 0.70; 95% confidence interval = 0.56-0.84; p = 0.018) was an independent risk factor significantly affected screw loosening.
CONCLUSIONS: Regional HU values of the screw trajectory could be a strong predictor of both primary and long-term screw fixation in vivo.

Entities:  

Keywords:  Bone density; Cortical bone trajectory; Hounsfield units; Insertional torque; Pedicle screw fixation; Screw loosening; Simulation analysis

Mesh:

Year:  2017        PMID: 29260301     DOI: 10.1007/s00701-017-3424-5

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  5 in total

1.  Factors important in bone union after posterior lumbar interbody fusion using the cortical bone trajectory technique.

Authors:  Yoshihide Yanai; Keitaro Matsukawa; Takashi Kato; Yoshiyuki Yato
Journal:  J Spine Surg       Date:  2020-12

2.  Pedicle Screws Loosening in Patients With Degenerative Diseases of the Lumbar Spine: Potential Risk Factors and Relative Contribution.

Authors:  Andrey Bokov; Anatoliy Bulkin; Alexander Aleynik; Marina Kutlaeva; Sergey Mlyavykh
Journal:  Global Spine J       Date:  2018-05-24

3.  Potential contribution of pedicle screw design to loosening rate in patients with degenerative diseases of the lumbar spine: An observational study.

Authors:  Andrey Bokov; Svetlana Pavlova; Anatoliy Bulkin; Alexandr Aleynik; Sergey Mlyavykh
Journal:  World J Orthop       Date:  2021-05-18

4.  A study of screw placement to obtain the optimal pull-out resistance of lumbar pedicle screws-analysis of Hounsfield units measurements based on computed tomography.

Authors:  Dachuan Li; Chi Sun; Jianyuan Jiang; Feizhou Lu; Xinlei Xia; Hongli Wang; Fei Zou; Xiaosheng Ma
Journal:  BMC Musculoskelet Disord       Date:  2022-02-07       Impact factor: 2.362

5.  Correlation between the Computed Tomography Values of the Screw Path and Pedicle Screw Pullout Strength: An Experimental Study in Porcine Vertebrae.

Authors:  Atsushi Ikeura; Taketoshi Kushida; Kenichi Oe; Yoshihisa Kotani; Muneharu Ando; Takashi Adachi; Takanori Saito
Journal:  Asian Spine J       Date:  2020-01-08
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.