Reply to comment by De Bernardo and Rosa on "Evaluation of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in keratoconus".

Fatih Özcura1, Nilgün Yıldırım2.   

Abstract

Entities:  

Mesh:

Year:  2017        PMID: 29254805      PMCID: PMC5904828          DOI: 10.1016/j.optom.2017.11.003

Source DB:  PubMed          Journal:  J Optom        ISSN: 1989-1342


× No keyword cloud information.
We would like to thank the De Bernardo and Rosa for their comment and interest in our study entitled “Evaluation of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in keratoconus” in which we compared three tonometers in patients with keratoconus. In this cross-sectional study, we concluded dynamic contour tonometry (DCT) may be the most appropriate tonometer to use in keratoconus for the measurements of intraocular pressure (IOP), because DCT do not appear to be dependent upon central corneal thickness (CCT) and corneal radius of curvature (CR). We compared these three tonometers in normal and glaucomatous eyes in another study. As the study of Lanza et al., we found that DCT has highest IOP measurements among these tonometers. Rebound tonometry (RT) was most influenced tonometer from CCT although all tonometers were significantly positive correlated with CCT except DCT in glaucomatous eyes. CR did not influence IOP measurements. Corneal biomechanical properties, such as corneal hysteresis (CH) and corneal resistance factor (CRF) are other factors that affect the measurement of IOP as you stressed. Both CH and CRF decrease in keratoconic corneas compared with normal corneas because of mechanical weakening of the stroma. Furthermore the analysis of these corneal biomechanical properties may contribute to early diagnosis of keratoconus in the future. Bayer et al. reported that both DCT and GAT were significantly influenced by CH and CRF. According to the regression models, DCT was slightly less affected from CH and CRF when compared with that of GAT. The magnitude of effect of CH and CRF on DCT measurements was quite different. The IOP decreases 1.78 mmHg/1 mmHg increase in CH and increases 1.83 mmHg/1 mmHg increase in CRF for the DCT. Because of the many difficulties in IOP measurements on the cornea especially with keratoconus, researchers and clinicians are interested in new tonometers that measure IOP independently of these corneal properties. The Goldmann applanation tonometer is currently the most widely used device in clinical practice, and is accepted as the gold standard method for IOP measurement. However, a new tonometer may be a gold standard in the near future.
  5 in total

1.  Comparison of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in normal and glaucomatous eyes.

Authors:  Fatih Özcura; Nilgün Yildirim; Afsun Şahin; Ertuğrul Çolak
Journal:  Int J Ophthalmol       Date:  2015-04-18       Impact factor: 1.779

2.  Corneal parameters and difference between goldmann applanation tonometry and dynamic contour tonometry in normal eyes.

Authors:  Michele Lanza; Maria Borrelli; Maddalena De Bernardo; Maria Luisa Filosa; Nicola Rosa
Journal:  J Glaucoma       Date:  2008-09       Impact factor: 2.503

Review 3.  Biomechanical properties of the keratoconic cornea: a review.

Authors:  Hans R Vellara; Dipika V Patel
Journal:  Clin Exp Optom       Date:  2015-01       Impact factor: 2.742

4.  Intraocular pressure values obtained by ocular response analyzer, dynamic contour tonometry, and goldmann tonometry in keratokonic corneas.

Authors:  Atilla Bayer; Afsun Sahin; Volkan Hürmeriç; Gökhan Ozge
Journal:  J Glaucoma       Date:  2010 Oct-Nov       Impact factor: 2.503

5.  Evaluation of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in keratoconus.

Authors:  Fatih Özcura; Nilgün Yıldırım; Emre Tambova; Afsun Şahin
Journal:  J Optom       Date:  2016-07-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.