Literature DB >> 29242728

Quantitative Single-Photon Emission Computed Tomography/Computed Tomography for Glomerular Filtration Rate Measurement.

Yeon-Koo Kang1, Sohyun Park1, Min Seok Suh1, Seok-Soo Byun2, Dong-Wan Chae3, Won Woo Lee1,4.   

Abstract

PURPOSE: We propose a quantitative Tc-99m diethylenetriaminepentaacetic acid (DTPA) single-photon emission computed tomography/computed tomography (SPECT/CT) for glomerular filtration rate (GFR) measurement.
METHODS: Quantitative SPECT/CT data obtained at 2-3 min post-Tc-99m DTPA injection (370 MBq) were used to determine % injected doses (%IDs) for individual kidneys. The reproducibility of %ID measurement was tested and compared with planar scintigraphy. Cr-51 ethylenediaminetetraacetic acid (EDTA) GFR was used as reference standard. Nine young volunteers, representing normal GFR, and ten older volunteers, reflecting impaired GFR, were enrolled. The established GFR equation derived from these volunteers was applied to 19 renal tumor patients post-partial nephrectomy.
RESULTS: At 2-3 min, %ID was most reproducible with the highest intraclass correlation (ICC) (0.9379) and lowest % coefficient of variation (CV) (6.5259%), which were more reliable than the ICC (0.9368) and %CV (6.7689%) of planar scintigraphy. Cr-51 EDTA GFR (93.16 ± 24.81 ml/min) correlated significantly with %ID (7.66 ± 2.15%, r = 0.7906, p = 0.0001), yielding an equation: Cr-51 EDTA GFR (ml/min) = (%ID × 9.1462) + 23.0653. This equation revealed significant decreases in total and nephrectomized kidney GFR (p = 0.0012 and p < 0.0001, respectively) from preoperative to 3-month postoperative measurements.
CONCLUSIONS: Quantitative Tc-99m DTPA SPECT/CT produces reliable and clinically applicable %ID estimates that translate to the GFR of individual kidneys.

Entities:  

Keywords:  Computed tomography; Cr-51 EDTA; Glomerular filtration rate; Single-photon emission computed tomography; Tc-99m DTPA

Year:  2017        PMID: 29242728      PMCID: PMC5721092          DOI: 10.1007/s13139-017-0491-8

Source DB:  PubMed          Journal:  Nucl Med Mol Imaging        ISSN: 1869-3474


  33 in total

1.  Comparison of methods for determination of glomerular filtration rate: Tc-99m-DTPA renography, predicted creatinine clearance method and plasma sample method.

Authors:  Kazuo Itoh
Journal:  Ann Nucl Med       Date:  2003-10       Impact factor: 2.668

2.  Description of a prototype emission-transmission computed tomography imaging system.

Authors:  T F Lang; B H Hasegawa; S C Liew; J K Brown; S C Blankespoor; S M Reilly; E L Gingold; C E Cann
Journal:  J Nucl Med       Date:  1992-10       Impact factor: 10.057

3.  The CARI guidelines. Donor renal function.

Authors:  Solomon Cohney; John Kanellis; Martin Howell
Journal:  Nephrology (Carlton)       Date:  2010-04       Impact factor: 2.506

4.  Effect of parenchymal volume preservation on kidney function after partial nephrectomy.

Authors:  Matthew N Simmons; Amr F Fergany; Steven C Campbell
Journal:  J Urol       Date:  2011-06-15       Impact factor: 7.450

Review 5.  An evidence-based review of quantitative SPECT imaging and potential clinical applications.

Authors:  Dale L Bailey; Kathy P Willowson
Journal:  J Nucl Med       Date:  2013-01       Impact factor: 10.057

6.  Comparison of 99mTc-DTPA renal dynamic imaging with modified MDRD equation for glomerular filtration rate estimation in Chinese patients in different stages of chronic kidney disease.

Authors:  Ying-Chun Ma; Li Zuo; Chun-Li Zhang; Mei Wang; Rong-Fu Wang; Hai-Yan Wang
Journal:  Nephrol Dial Transplant       Date:  2006-10-19       Impact factor: 5.992

7.  Ischemic renal damage after nephron-sparing surgery in patients with normal contralateral kidney.

Authors:  Yasuhito Funahashi; Ryohei Hattori; Tokunori Yamamoto; Osamu Kamihira; Katsuhiko Kato; Momokazu Gotoh
Journal:  Eur Urol       Date:  2008-08-05       Impact factor: 20.096

8.  Development of formulae for accurate measurement of the glomerular filtration rate by renal dynamic imaging.

Authors:  Qian Li; Chun-Li Zhang; Zhan-Li Fu; Rong-Fu Wang; Ying-Chun Ma; Li Zuo
Journal:  Nucl Med Commun       Date:  2007-05       Impact factor: 1.690

9.  Precision of SPECT/CT Allows the Diagnosis of a Hidden Brodie's Abscess of the Talus in a Patient with Sickle Cell Disease.

Authors:  Hassan Al-Jafar; Eman Al-Shemmeri; Jehan Al-Shemmeri; Leena Aytglu; Uzma Afzal; Saud Al-Enizi
Journal:  Nucl Med Mol Imaging       Date:  2014-12-03

10.  Quantification of 99mTc-DPD concentration in the lumbar spine with SPECT/CT.

Authors:  Michal Cachovan; Alexander Hans Vija; Joachim Hornegger; Torsten Kuwert
Journal:  EJNMMI Res       Date:  2013-06-05       Impact factor: 3.138

View more
  10 in total

Review 1.  Clinical Applications of Technetium-99m Quantitative Single-Photon Emission Computed Tomography/Computed Tomography.

Authors:  Won Woo Lee
Journal:  Nucl Med Mol Imaging       Date:  2019-03-15

Review 2.  KSNM 60 in General Nuclear Medicine: the Old Dream Comes True.

Authors:  Won Woo Lee; Jin-Sook Ryu
Journal:  Nucl Med Mol Imaging       Date:  2022-01-28

3.  Glomerular filtration rate calculation based on 68Ga-EDTA dynamic renal PET.

Authors:  Ying Ding; Du Zhang; Min Wang; Li Zhang; Yu Liu; Yinqian Deng; Dawei Jiang; Yuqing Liu; Wei Cao
Journal:  Am J Nucl Med Mol Imaging       Date:  2022-04-15

4.  White Matter Microstructure Changes and Cognitive Impairment in the Progression of Chronic Kidney Disease.

Authors:  Mengchen Liu; Yunfan Wu; Xixin Wu; Xiaofen Ma; Yi Yin; Huamei Fang; Sihua Huang; Huanhuan Su; Guihua Jiang
Journal:  Front Neurosci       Date:  2020-09-29       Impact factor: 4.677

5.  Minimum Standardized Uptake Value from Quantitative Bone Single-Photon Emission Computed Tomography/Computed Tomography for Evaluation of Femoral Head Viability in Patients with Femoral Neck Fracture.

Authors:  Hyun Gee Ryoo; Won Woo Lee; Ji Young Kim; Eunjung Kong; Woo Hee Choi; Joon-Kee Yoon
Journal:  Nucl Med Mol Imaging       Date:  2019-06-22

6.  Maximum standardized uptake value of foot SPECT/CT using Tc-99m HDP in patients with accessory navicular bone as a predictor of surgical treatment.

Authors:  Sungwoo Bae; Yusuhn Kang; Yoo Sung Song; Won Woo Lee
Journal:  Medicine (Baltimore)       Date:  2019-01       Impact factor: 1.889

7.  Quantitative salivary gland SPECT/CT using deep convolutional neural networks.

Authors:  Junyoung Park; Jae Sung Lee; Dongkyu Oh; Hyun Gee Ryoo; Jeong Hee Han; Won Woo Lee
Journal:  Sci Rep       Date:  2021-04-09       Impact factor: 4.379

8.  A retrospective multicenter study of quantitative bone SPECT/CT to predict the surgical removal of the accessory navicular bone.

Authors:  Ji-Young Kim; Ji Young Kim; Soo Bin Park; Chulhan Kim; Won Woo Lee
Journal:  Nucl Med Commun       Date:  2021-09-01       Impact factor: 1.698

9.  Quantitative Single-Photon Emission Computed Tomography/Computed Tomography for Evaluation of Salivary Gland Dysfunction in Sjögren's Syndrome Patients.

Authors:  Jihyun Kim; Hyunjong Lee; Hwanhee Lee; Ji-In Bang; Yeon-Koo Kang; Sungwoo Bae; Yoo Sung Song; Won Woo Lee
Journal:  Nucl Med Mol Imaging       Date:  2018-09-19

10.  The Usefulness of Maximum Standardized Uptake Value at the Delayed Phase of Tc-99m sestamibi single-photon emission computed tomography/computed tomography for Identification of Parathyroid Adenoma and Hyperplasia.

Authors:  Hoon Young Suh; Hee Young Na; So Yeon Park; June Young Choi; Young So; Won Woo Lee
Journal:  Medicine (Baltimore)       Date:  2020-07-10       Impact factor: 1.817

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.