Literature DB >> 2923754

Determination of the ratio of pulmonary blood flow to systemic blood flow by derivation of amplitude weighted mean velocity from continuous wave Doppler spectra.

R Jenni1, M Ritter, A Vieli, H O Hirzel, E R Schmid, J Grimm, M Turina.   

Abstract

Conventional Doppler echocardiographic techniques for the estimation of blood flow ratios depend on the precise measurement of the diameters of the aorta and the pulmonary artery and the mean blood flow velocities in these vessels. A simpler and quicker method is described, based on the calculation of the systolic time integrals of the amplitude weighted mean velocities from continuous wave Doppler spectra within the great arteries. In 30 controls the mean (2 SD) ratio of pulmonary to systemic blood flow averaged 0.952 (0.085). The results of the new technique showed a good agreement with those of quantitative dye dilution and oximetry in 16 patients with intracardiac left to right shunts.

Entities:  

Mesh:

Year:  1989        PMID: 2923754      PMCID: PMC1216635          DOI: 10.1136/hrt.61.2.167

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  6 in total

1.  Validation of a method for measuring the output of the right ventricle in man by inscription of dye-dilution curves from the pulmonary artery.

Authors:  H W FRITTS; P HARRIS; C A CHIDSEY; R H CLAUSS; A COURNAND
Journal:  J Appl Physiol       Date:  1957-11       Impact factor: 3.531

2.  Blood flow measurement using the attenuation-compensated volume flowmeter.

Authors:  C F Hottinger; J D Meindl
Journal:  Ultrason Imaging       Date:  1979-01       Impact factor: 1.578

3.  Confidence intervals rather than P values: estimation rather than hypothesis testing.

Authors:  M J Gardner; D G Altman
Journal:  Br Med J (Clin Res Ed)       Date:  1986-03-15

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Effect of flow disturbance on ultrasonic backscatter from blood.

Authors:  K K Shung; Y W Yuan; D Y Fei; J M Tarbell
Journal:  J Acoust Soc Am       Date:  1984-04       Impact factor: 1.840

6.  A theoretical study of the scattering of ultrasound from blood.

Authors:  B A Angelsen
Journal:  IEEE Trans Biomed Eng       Date:  1980-02       Impact factor: 4.538

  6 in total
  3 in total

1.  Noninvasive blood flow measurement and quantification of shunt volume by cine magnetic resonance in congenital heart disease. Preliminary results.

Authors:  L Sieverding; W I Jung; U Klose; J Apitz
Journal:  Pediatr Radiol       Date:  1992

2.  Outcome of pregnancy in women with congenital shunt lesions.

Authors:  M Zuber; N Gautschi; E Oechslin; V Widmer; W Kiowski; R Jenni
Journal:  Heart       Date:  1999-03       Impact factor: 5.994

3.  The Dynamic Relationship Between Asthma and Obesity in Schoolchildren.

Authors:  Yue Zhang; Zhanghua Chen; Kiros Berhane; Robert Urman; Vaia Lida Chatzi; Carrie Breton; Frank D Gilliland
Journal:  Am J Epidemiol       Date:  2020-06-01       Impact factor: 4.897

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.