Literature DB >> 29237080

Cardiopulmonary coupling spectrogram as an ambulatory clinical biomarker of sleep stability and quality in health, sleep apnea, and insomnia.

Robert Joseph Thomas1, Christopher Wood1, Matt Travis Bianchi2.   

Abstract

STUDY
OBJECTIVES: Ambulatory tracking of sleep and sleep pathology is rapidly increasing with the introduction of wearable devices. The objective of this study was to evaluate a wearable device which used novel computational analysis of the electrocardiogram (ECG), collected over multiple nights, as a method to track the dynamics of sleep quality in health and disease.
METHODS: This study used the ECG as a primary signal, a wearable device, the M1, and an analysis of cardiopulmonary coupling to estimate sleep quality. The M1 measures trunk movements, the ECG, body position, and snoring vibrations. Data from three groups of patients were analyzed: healthy participants and people with sleep apnea and insomnia, obtained from multiple nights of recording. Analysis focused on summary measures and night-to-night variability, specifically the intraclass coefficient.
RESULTS: Data were collected from 10 healthy participants, 18 people with positive pressure-treated sleep apnea, and 20 people with insomnia, 128, 65, and 121 nights, respectively. In any participant, all nights were consecutive. High-frequency coupling (HFC), the signal biomarker of stable breathing and stable sleep, showed high intraclass coefficients (ICCs) in healthy participants and people with sleep apnea (0.83, 0.89), but only 0.66 in people with insomnia. The only statistically significant difference between weekday and weekend in healthy subjects was HFC duration: 242.8 ± 53.8 vs. 275.8 ± 57.1 minutes (89 vs. 39 total nights), F(1,126) = 9.86, p = .002.
CONCLUSIONS: The M1 and similar wearable devices provide new opportunities to measure sleep in dynamic ways not possible before. These measurements can yield new biological insights and aid clinical management. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

Entities:  

Keywords:  ECG; ambulatory; apnea; cardiopulmonary coupling; insomnia; sleep

Year:  2018        PMID: 29237080      PMCID: PMC6018901          DOI: 10.1093/sleep/zsx196

Source DB:  PubMed          Journal:  Sleep        ISSN: 0161-8105            Impact factor:   5.849


  38 in total

1.  Sleep quality change after upper airway surgery in obstructive sleep apnea: Electrocardiogram-based cardiopulmonary coupling analysis.

Authors:  Ji Ho Choi; Robert J Thomas; Soo Yeon Suh; Il Ho Park; Tae Hoon Kim; Sang Hag Lee; Heung Man Lee; Chang-Ho Yun; Seung Hoon Lee
Journal:  Laryngoscope       Date:  2015-02-03       Impact factor: 3.325

2.  The spectrum of the non-rapid eye movement sleep electroencephalogram following total sleep deprivation is trait-like.

Authors:  Leila Tarokh; Thomas Rusterholz; Peter Achermann; Hans P A Van Dongen
Journal:  J Sleep Res       Date:  2015-01-29       Impact factor: 3.981

3.  Functional connectivity during rested wakefulness predicts vulnerability to sleep deprivation.

Authors:  B T Thomas Yeo; Jesisca Tandi; Michael W L Chee
Journal:  Neuroimage       Date:  2015-02-17       Impact factor: 6.556

4.  Sleep misperception in healthy adults: implications for insomnia diagnosis.

Authors:  Matt T Bianchi; Wei Wang; Elizabeth B Klerman
Journal:  J Clin Sleep Med       Date:  2012-10-15       Impact factor: 4.062

Review 5.  Shift work and inter-individual differences in sleep and sleepiness.

Authors:  Hans P A Van Dongen
Journal:  Chronobiol Int       Date:  2006       Impact factor: 2.877

Review 6.  Individual differences in adult human sleep and wakefulness: Leitmotif for a research agenda.

Authors:  Hans P A Van Dongen; Kristen M Vitellaro; David F Dinges
Journal:  Sleep       Date:  2005-04       Impact factor: 5.849

Review 7.  Not only … but also: REM sleep creates and NREM Stage 2 instantiates landmark junctions in cortical memory networks.

Authors:  Sue Llewellyn; J Allan Hobson
Journal:  Neurobiol Learn Mem       Date:  2015-04-25       Impact factor: 2.877

8.  Differentiating obstructive from central and complex sleep apnea using an automated electrocardiogram-based method.

Authors:  Robert Joseph Thomas; Joseph E Mietus; Chung-Kang Peng; Geoffrey Gilmartin; Robert W Daly; Ary L Goldberger; Daniel J Gottlieb
Journal:  Sleep       Date:  2007-12       Impact factor: 5.849

9.  Sleep quality changes in chronically depressed patients treated with Mindfulness-based Cognitive Therapy or the Cognitive Behavioral Analysis System of Psychotherapy: a pilot study.

Authors:  Preetam J Schramm; Ingo Zobel; Kathrin Mönch; Elisabeth Schramm; Johannes Michalak
Journal:  Sleep Med       Date:  2015-11-11       Impact factor: 3.492

10.  Consumer sleep monitors: is there a baby in the bathwater?

Authors:  Kathryn Russo; Balaji Goparaju; Matt T Bianchi
Journal:  Nat Sci Sleep       Date:  2015-11-05
View more
  13 in total

1.  Electrocardiogram-based sleep analysis for sleep apnea screening and diagnosis.

Authors:  Yan Ma; Shuchen Sun; Ming Zhang; Dan Guo; Arron Runzhou Liu; Yulin Wei; Chung-Kang Peng
Journal:  Sleep Breath       Date:  2019-06-21       Impact factor: 2.816

Review 2.  Phenotypic Subtypes of OSA: A Challenge and Opportunity for Precision Medicine.

Authors:  Andrey Zinchuk; Henry K Yaggi
Journal:  Chest       Date:  2019-09-17       Impact factor: 9.410

3.  Sleep staging from electrocardiography and respiration with deep learning.

Authors:  Haoqi Sun; Wolfgang Ganglberger; Ezhil Panneerselvam; Michael J Leone; Syed A Quadri; Balaji Goparaju; Ryan A Tesh; Oluwaseun Akeju; Robert J Thomas; M Brandon Westover
Journal:  Sleep       Date:  2020-07-13       Impact factor: 5.849

4.  Sleep apnea detection: accuracy of using automated ECG analysis compared to manually scored polysomnography (apnea hypopnea index).

Authors:  Hugi Hilmisson; Neale Lange; Stephen P Duntley
Journal:  Sleep Breath       Date:  2018-05-28       Impact factor: 2.816

5.  Cardiopulmonary Coupling.

Authors:  Mi Lu; Thomas Penzel; Robert J Thomas
Journal:  Adv Exp Med Biol       Date:  2022       Impact factor: 3.650

Review 6.  Reinventing polysomnography in the age of precision medicine.

Authors:  Diane C Lim; Diego R Mazzotti; Kate Sutherland; Jesse W Mindel; Jinyoung Kim; Peter A Cistulli; Ulysses J Magalang; Allan I Pack; Philip de Chazal; Thomas Penzel
Journal:  Sleep Med Rev       Date:  2020-03-20       Impact factor: 11.609

7.  Cardiopulmonary coupling and serum cardiac biomarkers in obesity hypoventilation syndrome and obstructive sleep apnea with morbid obesity.

Authors:  Sheila Sivam; David Wang; Keith K H Wong; Amanda J Piper; Yi Zhong Zheng; Gislaine Gauthier; Christine Hockings; Olivia McGuinness; Collette Menadue; Kerri Melehan; Sara Cooper; Hugi Hilmisson; Craig L Phillips; Robert J Thomas; Brendon J Yee; Ronald R Grunstein
Journal:  J Clin Sleep Med       Date:  2022-04-01       Impact factor: 4.062

8.  Social Jetlag and Chronotypes in the Chinese Population: Analysis of Data Recorded by Wearable Devices.

Authors:  Zhongxing Zhang; Christian Cajochen; Ramin Khatami
Journal:  J Med Internet Res       Date:  2019-05-11       Impact factor: 5.428

9.  Night-to-night variability of sleep electroencephalography-based brain age measurements.

Authors:  Jacob Hogan; Haoqi Sun; Luis Paixao; Mike Westmeijer; Pooja Sikka; Jing Jin; Ryan Tesh; Madalena Cardoso; Sydney S Cash; Oluwaseun Akeju; Robert Thomas; M Brandon Westover
Journal:  Clin Neurophysiol       Date:  2020-10-29       Impact factor: 3.708

10.  Impact of Catheter Ablation on Sleep Quality and Relationship Between Sleep Stability and Recurrence of Paroxysmal Atrial Fibrillation After Successful Ablation: 24-Hour Holter-Based Cardiopulmonary Coupling Analysis.

Authors:  Woohyeun Kim; Jin Oh Na; Robert J Thomas; Won Young Jang; Dong Oh Kang; Yoonjee Park; Jah Yeon Choi; Seung-Young Roh; Cheol Ung Choi; Jin Won Kim; Eung Ju Kim; Seung-Woon Rha; Chang Gyu Park; Hong Seog Seo; Hong Euy Lim
Journal:  J Am Heart Assoc       Date:  2020-11-26       Impact factor: 5.501

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.