Yan Ma1, Shuchen Sun2, Ming Zhang3, Dan Guo4, Arron Runzhou Liu4, Yulin Wei5, Chung-Kang Peng4. 1. Center for Dynamical Biomarkers, Division of Interdisciplinary Medicine and Biotechnology, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, Boston, MA, 02215, USA. dr.yan.ma@gmail.com. 2. Department of Otolaryngology and South Campus Sleep Center, Guang'anmen Hospital, China Academy of Chinese Medical Sciences, Beijing, 100053, China. sunsc0922@163.com. 3. Nanjing Integrated Traditional Chinese and Western Medicine Hospital, Nanjing, 210000, China. 4. Center for Dynamical Biomarkers, Division of Interdisciplinary Medicine and Biotechnology, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, Boston, MA, 02215, USA. 5. China-Japan Friendship Hospital, Beijing, 100029, China.
Abstract
PURPOSE: Despite the increasing number of research studies of cardiopulmonary coupling (CPC) analysis, an electrocardiogram-based technique, the use of CPC in underserved population remains underexplored. This study aimed to first evaluate the reliability of CPC analysis for the detection of obstructive sleep apnea (OSA) by comparing with polysomnography (PSG)-derived sleep outcomes. METHODS: Two hundred five PSG data (149 males, age 46.8 ± 12.8 years) were used for the evaluation of CPC regarding the detection of OSA. Automated CPC analyses were based on ECG signals only. Respiratory event index (REI) derived from CPC and apnea-hypopnea index (AHI) derived from PSG were compared for agreement tests. RESULTS: CPC-REI positively correlated with PSG-AHI (r = 0.851, p < 0.001). After adjusting for age and gender, CPC-REI and PSG-AHI were still significantly correlated (r = 0.840, p < 0.001). The overall results of sensitivity and specificity of CPC-REI were good. CONCLUSION: Compared with the gold standard PSG, CPC approach yielded acceptable results among OSA patients. ECG recording can be used for the screening or diagnosis of OSA in the general population.
PURPOSE: Despite the increasing number of research studies of cardiopulmonary coupling (CPC) analysis, an electrocardiogram-based technique, the use of CPC in underserved population remains underexplored. This study aimed to first evaluate the reliability of CPC analysis for the detection of obstructive sleep apnea (OSA) by comparing with polysomnography (PSG)-derived sleep outcomes. METHODS: Two hundred five PSG data (149 males, age 46.8 ± 12.8 years) were used for the evaluation of CPC regarding the detection of OSA. Automated CPC analyses were based on ECG signals only. Respiratory event index (REI) derived from CPC and apnea-hypopnea index (AHI) derived from PSG were compared for agreement tests. RESULTS:CPC-REI positively correlated with PSG-AHI (r = 0.851, p < 0.001). After adjusting for age and gender, CPC-REI and PSG-AHI were still significantly correlated (r = 0.840, p < 0.001). The overall results of sensitivity and specificity of CPC-REI were good. CONCLUSION: Compared with the gold standard PSG, CPC approach yielded acceptable results among OSA patients. ECG recording can be used for the screening or diagnosis of OSA in the general population.
Authors: Seung Hoon Lee; Ji Ho Choi; Il Ho Park; Sang Hag Lee; Tae Hoon Kim; Heung Man Lee; Hee-Kwon Park; Robert J Thomas; Chol Shin; Chang-Ho Yun Journal: Laryngoscope Date: 2012-06-27 Impact factor: 3.325
Authors: Yan Ma; Alicia Yeung; Albert C Yang; Chung-Kang Peng; Alisabet Clain; Jonathan Alpert; Maurizio Fava; Albert S Yeung Journal: Behav Sleep Med Date: 2016-09-27 Impact factor: 2.964
Authors: Thomas Penzel; Jan W Kantelhardt; Ronny P Bartsch; Maik Riedl; Jan F Kraemer; Niels Wessel; Carmen Garcia; Martin Glos; Ingo Fietze; Christoph Schöbel Journal: Front Physiol Date: 2016-10-25 Impact factor: 4.566
Authors: Nathan Zavanelli; Hojoong Kim; Jongsu Kim; Robert Herbert; Musa Mahmood; Yun-Soung Kim; Shinjae Kwon; Nicholas B Bolus; F Brennan Torstrick; Christopher S D Lee; Woon-Hong Yeo Journal: Sci Adv Date: 2021-12-22 Impact factor: 14.136
Authors: Mario Alan Quiroz-Juárez; Juan Alberto Rosales-Juárez; Omar Jiménez-Ramírez; Rubén Vázquez-Medina; José Luis Aragón Journal: Sensors (Basel) Date: 2022-07-30 Impact factor: 3.847