Literature DB >> 29207842

A Three Month Comparative Evaluation of the Effect of Different Surface Treatment Agents on the Surface Integrity and Softness of Acrylic based Soft Liner: An In vivo Study.

Harekrishna Jayendra Raval1, Neerja Mahajan2, Y G Naveen3, Rajesh Sethuraman4.   

Abstract

INTRODUCTION: Acrylic based soft liners are cost effective, yet are inferior in durability as compared to silicone based liners. Hence, this study was conducted to evaluate if the softness and surface integrity of acrylic based soft liner can be maintained by using different surface treatment agents. AIM: To comparatively evaluate the effects of Varnish, Monopoly and Kregard surface treatment agents on the surface integrity and softness of acrylic based soft liner at baseline, at one month and after three months.
MATERIALS AND METHODS: A total of 37 participants who required conventional maxillary dentures were selected according to the determined inclusion and exclusion criteria of the study. In the maxillary denture on the denture bearing surface, eight palatal recesses (5 mm x 3 mm) were made and filled with acrylic based soft liner (Permasoft). The soft liners in these recesses were given surface treatment and divided as control (uncoated), Varnish, Monopoly and Kregard groups. The hardness and surface integrity were evaluated with Shore A Durometer and Scanning Electron Microscope (SEM) respectively at baseline, one month and three months interval. Surface integrity between groups was compared using Kruskal-Wallis test. Intergroup comparison for hardness was done using ANOVA and Tukey's HSD post-hoc tests.
RESULTS: Amongst all the groups tested, surface integrity was maintained in the Kregard group, as compared to control, Varnish and Monopoly groups for all three time intervals (p< 0.001). Kregard treated samples also demonstrated significantly higher softness at all the time intervals (p<0.001).
CONCLUSION: Surface treatment with Kregard demonstrated better surface integrity and softness at all the time intervals.

Entities:  

Keywords:  Denture bearing surface; Durometer; Hardness

Year:  2017        PMID: 29207842      PMCID: PMC5713864          DOI: 10.7860/JCDR/2017/28604.10680

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  19 in total

1.  Effect of thermocycling on bond strength and elasticity of 4 long-term soft denture liners.

Authors:  José Renato Ribeiro Pinto; Marcelo Ferraz Mesquita; Guilherme Elias Pessanha Henriques; Mauro Antôonio de Arruda Nóbilo
Journal:  J Prosthet Dent       Date:  2002-11       Impact factor: 3.426

2.  Effect of sealer coating on mechanical and physical properties of permanent soft lining materials.

Authors:  Andreza Dayrell; Jessica Takahashi; Guilherme Valverde; Rafael Consani; Glaucia Ambrosano; Marcelo Mesquita
Journal:  Gerodontology       Date:  2011-05-02       Impact factor: 2.980

3.  Denture plaque distribution and the effectiveness of a perborate-containing denture cleanser.

Authors:  S B Keng; M Lim
Journal:  Quintessence Int       Date:  1996-05       Impact factor: 1.677

4.  Resiliency of surface-sealed temporary soft denture liners.

Authors:  P M Gronet; C F Driscoll; S O Hondrum
Journal:  J Prosthet Dent       Date:  1997-04       Impact factor: 3.426

5.  Influence of curing method, sealer, and water storage on the hardness of a soft lining material over time.

Authors:  G L Polyzois; M J Frangou
Journal:  J Prosthodont       Date:  2001-03       Impact factor: 2.752

6.  Surface treatment of a temporary soft liner for increased longevity.

Authors:  D M Casey; E C Scheer
Journal:  J Prosthet Dent       Date:  1993-03       Impact factor: 3.426

7.  Surface modification of an experimental silicone rubber aimed at reducing initial candidal adhesion.

Authors:  C Price; M G J Waters; D W Williams; M A O Lewis; D Stickler
Journal:  J Biomed Mater Res       Date:  2002

8.  The influence of patient characteristics on acrylic-based resilient denture liners embedded in maxillary complete dentures.

Authors:  Akina Ogawa; Suguru Kimoto; Hiroyuki Saeki; Masanori Ono; Nobuhiko Furuse; Yasuhiko Kawai
Journal:  J Prosthodont Res       Date:  2016-01-06       Impact factor: 4.642

9.  Comparison of bond strength of six soft denture liners to denture base resin.

Authors:  F Kawano; E R Dootz; A Koran; R G Craig
Journal:  J Prosthet Dent       Date:  1992-08       Impact factor: 3.426

10.  Tissue conditioners protected by a poly(methyl methacrylate) coating.

Authors:  N E Dominguez; C J Thomas; T M Gerzina
Journal:  Int J Prosthodont       Date:  1996 Mar-Apr       Impact factor: 1.681

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.