Biomonitoring method for the analysis of chromium and cobalt in human whole blood using inductively coupled plasma - kinetic energy discrimination - mass spectrometry (ICP-KED-MS).

Joaudimir Castro Georgi1, Yuliya L Sommer1, Cynthia D Ward1, Po-Yung Cheng1, Robert L Jones1, Kathleen L Caldwell1.   

Abstract

The Centers for Disease Control and Prevention developed a biomonitoring method to rapidly and accurately quantify chromium and cobalt in human whole blood by ICP-MS. Many metal-on-metal hip implants which contain significant amounts of chromium and cobalt are susceptible to metal degradation. This method is used to gather population data about chromium and cobalt exposure of the U.S. population that does not include people that have metal-on-metal hip implants so that reference value can be established for a baseline level in blood. We evaluated parameters such as; helium gas flow rate, choice and composition of the diluent solution for sample preparation, and sample rinse time to determine the optimal conditions for analysis. The limits of detection for chromium and cobalt in blood were determined to be 0.41 and 0.06 μg/L, respectively. Method precision, accuracy, and recovery for this method were determined using quality control material created in-house and historical proficiency testing samples. We conducted experiments to determine if quantitative changes in the method parameters affect the results obtained by changing four parameters while analyzing human whole blood spiked with National Institute of Standard and Technology traceable materials: the dilution factor used during sample preparation, sample rinse time, diluent composition, and kinetic energy discrimination gas flow rate. The results at the increased and decreased levels for each parameter were statistically compared to the results obtained at the optimized parameters. We assessed the degree of reproducibility obtained under a variety of conditions and evaluated the method's robustness by analyzing the same set of proficiency testing samples by different analysts, on different instruments, with different reagents, and on different days. The short-term stability of chromium and cobalt in human blood samples stored at room temperature was monitored over a time period of 64 hours by diluting and analyzing samples at different time intervals. The stability of chromium and cobalt post-dilution was also evaluated over a period of 48 hours and at two storage temperatures (room temperature and refrigerated at 4°C). The results obtained during the stability studies showed that chromium and cobalt are stable in human blood for a period of 64 hours.

Entities:  

Year:  2017        PMID: 29201158      PMCID: PMC5709816          DOI: 10.1039/C7AY00430C

Source DB:  PubMed          Journal:  Anal Methods        ISSN: 1759-9660            Impact factor:   2.896


  22 in total

1.  Medical management guidelines for unidentified chemicals.

Authors: 
Journal:  Occup Health Saf       Date:  2006-12

2.  Simultaneous quantification of 17 trace elements in blood by dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS) equipped with a high-efficiency sample introduction system.

Authors:  S D'Ilio; N Violante; M Di Gregorio; O Senofonte; F Petrucci
Journal:  Anal Chim Acta       Date:  2006-07-18       Impact factor: 6.558

3.  Sensitivity and specificity of blood cobalt and chromium metal ions for predicting failure of metal-on-metal hip replacement.

Authors:  A J Hart; S A Sabah; A S Bandi; P Maggiore; P Tarassoli; B Sampson; J A Skinner
Journal:  J Bone Joint Surg Br       Date:  2011-10

4.  An ORS-ICP-MS method for monitoring trace levels of cobalt and chromium in whole blood samples from hip arthroplasty patients with metal-on-metal prostheses.

Authors:  K L Pei; D W Kinniburgh; L Butlin; P Faris; D Lee; D A Marshall; M C Oliver; R Parker; J N Powell; P Railton; J Smith
Journal:  Clin Biochem       Date:  2012-03-30       Impact factor: 3.281

5.  Essentiality of chromium in humans.

Authors:  R A Anderson
Journal:  Sci Total Environ       Date:  1989-10-01       Impact factor: 7.963

6.  High-resolution ICP-MS determination of Ti, V, Cr, Co, Ni, and Mo in human blood and urine of patients implanted with a hip or knee prosthesis.

Authors:  Alejandro Sarmiento-González; Juan Manuel Marchante-Gayón; José María Tejerina-Lobo; José Paz-Jiménez; Alfredo Sanz-Medel
Journal:  Anal Bioanal Chem       Date:  2008-06-08       Impact factor: 4.142

Review 7.  Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip.

Authors:  P-A Vendittoli; S Mottard; A G Roy; C Dupont; M Lavigne
Journal:  J Bone Joint Surg Br       Date:  2007-04

8.  Highly sensitive measurement of whole blood chromium by inductively coupled plasma mass spectrometry.

Authors:  Wendy Cieslak; Kathleen Pap; Dustin R Bunch; Edmunds Reineks; Raymond Jackson; Roxanne Steinle; Sihe Wang
Journal:  Clin Biochem       Date:  2012-11-02       Impact factor: 3.281

9.  Total blood mercury concentrations in the U.S. population: 1999-2006.

Authors:  Kathleen L Caldwell; Mary E Mortensen; Robert L Jones; Samuel P Caudill; John D Osterloh
Journal:  Int J Hyg Environ Health       Date:  2009-05-29       Impact factor: 5.840

10.  Circulating levels of cobalt and chromium from metal-on-metal hip replacement are associated with CD8+ T-cell lymphopenia.

Authors:  A J Hart; J A Skinner; P Winship; N Faria; E Kulinskaya; D Webster; S Muirhead-Allwood; C H Aldam; H Anwar; J J Powell
Journal:  J Bone Joint Surg Br       Date:  2009-06
View more
  2 in total

1.  Importance of Preanalytical Factors in Measuring Cr and Co Levels in Human Whole Blood: Contamination Control, Proper Sample Collection and Long-Term Storage Stability.

Authors:  Yuliya L Sommer; Cynthia D Ward; Joaudimir Castro Georgi; Po-Yung Cheng; Robert L Jones
Journal:  J Anal Toxicol       Date:  2021-03-12       Impact factor: 3.367

2.  Development and validation of a biomonitoring method to measure As, Cr, and Ni in human urine samples by ICP-UCT-MS.

Authors:  Deanna R Jones; Jeffery M Jarrett; Danielle Stukes; Adam Baer; Megan McMichael; Kristen Wallon; Ge Xiao; Robert L Jones
Journal:  Int J Hyg Environ Health       Date:  2021-02-20       Impact factor: 5.840