Literature DB >> 33621861

Development and validation of a biomonitoring method to measure As, Cr, and Ni in human urine samples by ICP-UCT-MS.

Deanna R Jones1, Jeffery M Jarrett2, Danielle Stukes3, Adam Baer3, Megan McMichael3, Kristen Wallon2, Ge Xiao2, Robert L Jones2.   

Abstract

We developed an inductively coupled plasma mass spectrometry (ICP-MS) method using Universal Cell Technology (UCT) with a PerkinElmer NexION ICP-MS, to measure arsenic (As), chromium (Cr), and nickel (Ni) in human urine samples. The advancements of the UCT allowed us to expand the calibration range to make the method applicable for both low concentrations of biomonitoring applications and high concentrations that may be observed from acute exposures and emergency response. Our method analyzes As and Ni in kinetic energy discrimination (KED) mode with helium (He) gas, and Cr in dynamic reaction cell (DRC) mode with ammonia (NH3) gas. The combination of these elements is challenging because a carbon source, ethanol (EtOH), is required for normalization of As ionization in urine samples, which creates a spectral overlap (40Ar12C+) on 52Cr. This method additionally improved lab efficiency by combining elements from two of our previously published methods(Jarrett et al., 2007; Quarles et al., 2014) allowing us to measure Cr and Ni concentrations in urine samples collected as part of the National Health and Nutrition Examination Survey (NHANES) beginning with the 2017-2018 survey cycle. We present our rigorous validation of the method selectivity and accuracy using National Institute of Standards and Technology (NIST) Standard Reference Materials (SRM), precision using in-house prepared quality control materials, and a discussion of the use of a modified UCT, a BioUCell, to address an ion transmission phenomenon we observed on the NexION 300 platform when using higher elemental concentrations and high cell gas pressures. The rugged method detection limits, calculated from measurements in more than 60 runs, for As, Cr, and Ni are 0.23 μg L-1, 0.19 μg L-1, and 0.31 μg L-1, respectively. Published by Elsevier GmbH.

Entities:  

Keywords:  Arsenic (As); Biomonitoring; Chromium (Cr); Dynamic reaction cell (DRC); ICP-MS; Kinetic energy discrimination (KED); Nickel (Ni)

Mesh:

Substances:

Year:  2021        PMID: 33621861      PMCID: PMC8134962          DOI: 10.1016/j.ijheh.2021.113713

Source DB:  PubMed          Journal:  Int J Hyg Environ Health        ISSN: 1438-4639            Impact factor:   5.840


  20 in total

1.  Application of inductively coupled plasma sector field mass spectrometry for elemental analysis of urine.

Authors:  I Rodushkin; F Odman
Journal:  J Trace Elem Med Biol       Date:  2001-04       Impact factor: 3.849

2.  Determination of arsenite, arsenate, and monomethylarsonic acid in seawater by ion-exclusion chromatography combined with inductively coupled plasma mass spectrometry using reaction cell and hydride generation techniques.

Authors:  Tetsuya Nakazato; Hiroaki Tao; Tadashi Taniguchi; Kenji Isshiki
Journal:  Talanta       Date:  2002-08-16       Impact factor: 6.057

3.  Application of ICP-MS and HPLC-ICP-MS for diagnosis and therapy of a severe intoxication with hexavalent chromium and inorganic arsenic.

Authors:  Peter Heitland; Martin Blohm; Christian Breuer; Florian Brinkert; Eike Gert Achilles; Ieva Pukite; Helmut Dietrich Köster
Journal:  J Trace Elem Med Biol       Date:  2017-02-16       Impact factor: 3.849

4.  Comparison of representative ranges based on U.S. patient population and literature reference intervals for urinary trace elements.

Authors:  G Komaromy-Hiller; K O Ash; R Costa; K Howerton
Journal:  Clin Chim Acta       Date:  2000-06       Impact factor: 3.786

5.  Arsenic poisoning caused by intentional contamination of coffee at a church gathering--an epidemiological approach to a forensic investigation.

Authors:  Kathleen F Gensheimer; Vicki Rea; Dora Anne Mills; Christopher P Montagna; Karen Simone
Journal:  J Forensic Sci       Date:  2010-04-08       Impact factor: 1.832

6.  Arsenic determination by ICP-QMS with octopole collision/reaction cell. Overcome of matrix effects under vented and pressurized cell conditions.

Authors:  Mireia Colon; Manuela Hidalgo; Mònica Iglesias
Journal:  Talanta       Date:  2011-07-18       Impact factor: 6.057

7.  Biomonitoring of metal in children living in a mine tailings zone in Southern Mexico: A pilot study.

Authors:  María Elena Moreno; Leonor C Acosta-Saavedra; Diana Meza-Figueroa; Eunice Vera; Mariano E Cebrian; Patricia Ostrosky-Wegman; Emma S Calderon-Aranda
Journal:  Int J Hyg Environ Health       Date:  2010-04-24       Impact factor: 5.840

8.  Multi-rule quality control for the age-related eye disease study.

Authors:  Samuel P Caudill; Rosemary L Schleicher; James L Pirkle
Journal:  Stat Med       Date:  2008-09-10       Impact factor: 2.373

9.  Multi-element analysis of urine using dynamic reaction cell inductively coupled plasma mass spectrometry (ICP-DRC-MS) - a practical application.

Authors:  Renata Brodzka; Małgorzata Trzcinka-Ochocka; Beata Janasik
Journal:  Int J Occup Med Environ Health       Date:  2013-06-15       Impact factor: 1.843

10.  Levels of urinary total and speciated arsenic in the US population: National Health and Nutrition Examination Survey 2003-2004.

Authors:  Kathleen L Caldwell; Robert L Jones; Carl P Verdon; Jeffery M Jarrett; Samuel P Caudill; John D Osterloh
Journal:  J Expo Sci Environ Epidemiol       Date:  2008-06-04       Impact factor: 5.563

View more
  1 in total

1.  Mediation Effect of Body Mass Index on the Association of Urinary Nickel Exposure with Serum Lipid Profiles.

Authors:  Sibo Wang; Tiankai Shan; Jun Zhu; Qiqi Jiang; Lingfeng Gu; Jiateng Sun; Yulin Bao; Bo Deng; Hao Wang; Liansheng Wang
Journal:  Biol Trace Elem Res       Date:  2022-08-01       Impact factor: 4.081

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.