Literature DB >> 29200592

Reduction of Beam Hardening Artifacts in Cone-Beam CT Imaging via SMART-RECON Algorithm.

Yinsheng Li1, John Garrett1, Guang-Hong Chen1,2.   

Abstract

When an automatic exposure control is introduced in C-arm cone beam CT data acquisition, the spectral inconsistencies between acquired projection data are exacerbated. As a result, conventional water/bone correction schemes are not as effective as in conventional diagnostic x-ray CT acquisitions with a fixed tube potential. In this paper, a new method was proposed to reconstruct several images with different degrees of spectral consistency and thus different levels of beam hardening artifacts. The new method relies neither on prior knowledge of the x-ray beam spectrum nor on prior compositional information of the imaging object. Numerical simulations were used to validate the algorithm.

Entities:  

Keywords:  Beam hardening artifacts; C-arm Cone Beam Computer Tomography (CT); Consistency driven iterative image reconstruction; Spectral inconsistency

Year:  2016        PMID: 29200592      PMCID: PMC5710817          DOI: 10.1117/12.2216882

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  2 in total

1.  Empirical beam hardening correction (EBHC) for CT.

Authors:  Yiannis Kyriakou; Esther Meyer; Daniel Prell; Marc Kachelriess
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

2.  Synchronized multiartifact reduction with tomographic reconstruction (SMART-RECON): A statistical model based iterative image reconstruction method to eliminate limited-view artifacts and to mitigate the temporal-average artifacts in time-resolved CT.

Authors:  Guang-Hong Chen; Yinsheng Li
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

  2 in total
  4 in total

1.  Synthetic CT generation from CBCT images via deep learning.

Authors:  Liyuan Chen; Xiao Liang; Chenyang Shen; Steve Jiang; Jing Wang
Journal:  Med Phys       Date:  2020-01-13       Impact factor: 4.071

2.  Automatic quantification framework to detect cracks in teeth.

Authors:  Hina Shah; Pablo Hernandez; Francois Budin; Deepak Chittajallu; Jean-Baptiste Vimort; Rick Walters; André Mol; Asma Khan; Beatriz Paniagua
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-12

3.  Multitask 3D CBCT-to-CT translation and organs-at-risk segmentation using physics-based data augmentation.

Authors:  Navdeep Dahiya; Sadegh R Alam; Pengpeng Zhang; Si-Yuan Zhang; Tianfang Li; Anthony Yezzi; Saad Nadeem
Journal:  Med Phys       Date:  2021-08-09       Impact factor: 4.506

Review 4.  Technical Principles of Dual-Energy Cone Beam Computed Tomography and Clinical Applications for Radiation Therapy.

Authors:  Shailaja Sajja; Young Lee; Markus Eriksson; Håkan Nordström; Arjun Sahgal; Masoud Hashemi; James G Mainprize; Mark Ruschin
Journal:  Adv Radiat Oncol       Date:  2019-07-30
  4 in total