Literature DB >> 29194944

Relationship between implant stability measurements obtained by insertion torque and resonance frequency analysis: A systematic review.

Frederico Santos Lages1, Dhelfeson Willya Douglas-de Oliveira1, Fernando Oliveira Costa1.   

Abstract

BACKGROUND: The primary stability of dental implants can be evaluated by insertion torque (IT) and resonance frequency analysis (RFA).
OBJECTIVE: Assess the supposed relationship between the IT and RFA.
MATERIALS AND METHODS: A systematic review was performed based on the PRISMA. The electronic search was performed in the PubMed, Web of Science, SCOPUS, Cochrane Library electronic, OVID, and Scielo databases. Manual searches were also performed. There was no restrictions regarding year of publication or language. The articles identified were assessed independently by 3 trained researchers. Clinical trials reporting the RFA values by means of implant stability quotient (ISQ) and IT were included.
RESULTS: The electronic and manual searches yielded 2017 studies. Twelve studies were included in the systematic review. There was no statistically significant correlation between ISQ and IT (rs  = .366; P = .079). The quality of the evidence was downgraded by risk of bias and indirectness; and the certainty of the evidence was low.
CONCLUSION: IT and RFA are independent and incomparable methods of measuring primary stability. Is important for clinicians to define only one method of evaluation for each implant.
© 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  Osstell; dental implant; osseointegration; torque

Mesh:

Substances:

Year:  2017        PMID: 29194944     DOI: 10.1111/cid.12565

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  31 in total

Review 1.  Biomechanical behaviours of the bone-implant interface: a review.

Authors:  Xing Gao; Manon Fraulob; Guillaume Haïat
Journal:  J R Soc Interface       Date:  2019-07-31       Impact factor: 4.118

2.  Intra- and inter-operator concordance of the resonance frequency analysis. A cross-sectional and prospective clinical study.

Authors:  Raquel Antequera-Diaz; Maria-Pilar Quesada-García; Cristina Vallecillo; Marta Vallecillo-Rivas; Esther Muñoz-Soto; Maria-Victoria Olmedo-Gaya
Journal:  Clin Oral Investig       Date:  2022-07-08       Impact factor: 3.573

3.  Significance of bone morphology and quality on the primary stability of orthodontic mini-implants: in vitro comparison between human bone substitute and artificial bone.

Authors:  Sachin Chhatwani; Ouafaa Kouji-Diehl; Kristian Kniha; Ali Modabber; Frank Hölzle; Jozsef Szalma; Gholamreza Danesh; Stephan Christian Möhlhenrich
Journal:  J Orofac Orthop       Date:  2022-03-18       Impact factor: 1.938

4.  Marginal Bone Level and Bone Thickness Reduction in Delayed and Immediate Implant Placement Protocol 6 Months Post-loading: An Observational Clinical Prospective Study.

Authors:  Maroun Dagher; Nadim Mokbel; Rami Aboukhalil; Nabil Ghosn; Abdelrahman Kassir; Nada Naaman
Journal:  J Maxillofac Oral Surg       Date:  2022-01-07

5.  Does Biphasic Calcium Phosphate-Coated Surface Increase the Secondary Stability in Dental Implants? A Split-Mouth Study.

Authors:  Reza Tabrizi; Hassan Mirmohammad Sadeghi; Kimia Ghasemi; Adel Khayati; Mohammad Jafarian
Journal:  J Maxillofac Oral Surg       Date:  2020-09-24

6.  Validation of an implant stability measurement device using the percussion response: a clinical research study.

Authors:  Yurie Okuhama; Koudai Nagata; Hyunjin Kim; Hayato Tsuruoka; Mihoko Atsumi; Hiromasa Kawana
Journal:  BMC Oral Health       Date:  2022-07-14       Impact factor: 3.747

7.  Effect of macro-design in the primary stability of short and extra-short implants using resonance frequency analysis. An ex vivo study.

Authors:  Ramón Silva; Pablo Villalón; Felipe Cáceres
Journal:  J Oral Biol Craniofac Res       Date:  2020-08-29

8.  A study on the use of the Osstell apparatus to evaluate pedicle screw stability: An in-vitro study using micro-CT.

Authors:  Daisuke Nakashima; Ken Ishii; Morio Matsumoto; Masaya Nakamura; Takeo Nagura
Journal:  PLoS One       Date:  2018-06-28       Impact factor: 3.240

9.  Correlation between Insertion Torque and Implant Stability Quotient in Tapered Implants with Knife-Edge Thread Design.

Authors:  Domenico Baldi; Teresa Lombardi; Jacopo Colombo; Gabriele Cervino; Giuseppe Perinetti; Roberto Di Lenarda; Claudio Stacchi
Journal:  Biomed Res Int       Date:  2018-05-15       Impact factor: 3.411

10.  Clinical Relevance of Bone Density Values from CT Related to Dental Implant Stability: A Retrospective Study.

Authors:  Vincenzo Bruno; Cesare Berti; Carlo Barausse; Mauro Badino; Roberta Gasparro; Daniela Rita Ippolito; Pietro Felice
Journal:  Biomed Res Int       Date:  2018-05-31       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.