Literature DB >> 29193448

Increased CEST specificity for amide and fast-exchanging amine protons using exchange-dependent relaxation rate.

Xiao-Yong Zhang1,2, Feng Wang1,2, Junzhong Xu1,2,3,4, Daniel F Gochberg1,2,3, John C Gore1,2,3,4,5, Zhongliang Zu1,2.   

Abstract

Chemical exchange saturation transfer (CEST) imaging of amides at 3.5 ppm and fast-exchanging amines at 3 ppm provides a unique means to enhance the sensitivity of detection of, for example, proteins/peptides and neurotransmitters, respectively, and hence can provide important information on molecular composition. However, despite the high sensitivity relative to conventional magnetic resonance spectroscopy (MRS), in practice, CEST often has relatively poor specificity. For example, CEST signals are typically influenced by several confounding effects, including direct water saturation (DS), semi-solid non-specific magnetization transfer (MT), the influence of water relaxation times (T1w ) and nearby overlapping CEST signals. Although several editing techniques have been developed to increase the specificity by removing DS, semi-solid MT and T1w influences, it is still challenging to remove overlapping CEST signals from different exchanging sites. For instance, the amide proton transfer (APT) signal could be contaminated by CEST effects from fast-exchanging amines at 3 ppm and intermediate-exchanging amines at 2 ppm. The current work applies an exchange-dependent relaxation rate (Rex ) to address this problem. Simulations demonstrate that: (1) slowly exchanging amides and fast-exchanging amines have distinct dependences on irradiation powers; and (2) Rex serves as a resonance frequency high-pass filter to selectively reduce CEST signals with resonance frequencies closer to water. These characteristics of Rex provide a means to isolate the APT signal from amines. In addition, previous studies have shown that CEST signals from fast-exchanging amines have no distinct features around their resonance frequencies. However, Rex gives Lorentzian lineshapes centered at their resonance frequencies for fast-exchanging amines and thus can significantly increase the specificity of CEST imaging for amides and fast-exchanging amines.
Copyright © 2017 John Wiley & Sons, Ltd.

Entities:  

Keywords:  APT; CEST; MRI; fast-exchanging amine; specificity

Mesh:

Substances:

Year:  2017        PMID: 29193448      PMCID: PMC5773365          DOI: 10.1002/nbm.3863

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  64 in total

1.  Modeling magnetization transfer for biological-like systems using a semi-solid pool with a super-Lorentzian lineshape and dipolar reservoir.

Authors:  C Morrison; G Stanisz; R M Henkelman
Journal:  J Magn Reson B       Date:  1995-08

2.  Exchange-dependent relaxation in the rotating frame for slow and intermediate exchange -- modeling off-resonant spin-lock and chemical exchange saturation transfer.

Authors:  Moritz Zaiss; Peter Bachert
Journal:  NMR Biomed       Date:  2012-12-28       Impact factor: 4.044

3.  Amide proton transfer MR imaging of prostate cancer: a preliminary study.

Authors:  Guang Jia; Ronney Abaza; JoAnna D Williams; Debra L Zynger; Jinyuan Zhou; Zarine K Shah; Mitva Patel; Steffen Sammet; Lai Wei; Robert R Bahnson; Michael V Knopp
Journal:  J Magn Reson Imaging       Date:  2011-03       Impact factor: 4.813

4.  CEST imaging of fast exchanging amine pools with corrections for competing effects at 9.4 T.

Authors:  Xiao-Yong Zhang; Feng Wang; Hua Li; Junzhong Xu; Daniel F Gochberg; John C Gore; Zhongliang Zu
Journal:  NMR Biomed       Date:  2017-03-08       Impact factor: 4.044

5.  Accuracy in the quantification of chemical exchange saturation transfer (CEST) and relayed nuclear Overhauser enhancement (rNOE) saturation transfer effects.

Authors:  Xiao-Yong Zhang; Feng Wang; Hua Li; Junzhong Xu; Daniel F Gochberg; John C Gore; Zhongliang Zu
Journal:  NMR Biomed       Date:  2017-03-08       Impact factor: 4.044

6.  Association between pH-weighted endogenous amide proton chemical exchange saturation transfer MRI and tissue lactic acidosis during acute ischemic stroke.

Authors:  Phillip Zhe Sun; Jerry S Cheung; Enfeng Wang; Eng H Lo
Journal:  J Cereb Blood Flow Metab       Date:  2011-03-09       Impact factor: 6.200

7.  Spin-locking versus chemical exchange saturation transfer MRI for investigating chemical exchange process between water and labile metabolite protons.

Authors:  Tao Jin; Joonas Autio; Takayuki Obata; Seong-Gi Kim
Journal:  Magn Reson Med       Date:  2010-11-30       Impact factor: 4.668

8.  A combined analytical solution for chemical exchange saturation transfer and semi-solid magnetization transfer.

Authors:  Moritz Zaiss; Zhongliang Zu; Junzhong Xu; Patrick Schuenke; Daniel F Gochberg; John C Gore; Mark E Ladd; Peter Bachert
Journal:  NMR Biomed       Date:  2014-12-15       Impact factor: 4.044

9.  Dynamic glucose enhanced (DGE) MRI for combined imaging of blood-brain barrier break down and increased blood volume in brain cancer.

Authors:  Xiang Xu; Kannie W Y Chan; Linda Knutsson; Dmitri Artemov; Jiadi Xu; Guanshu Liu; Yoshinori Kato; Bachchu Lal; John Laterra; Michael T McMahon; Peter C M van Zijl
Journal:  Magn Reson Med       Date:  2015-09-25       Impact factor: 4.668

10.  MRI detection of glycogen in vivo by using chemical exchange saturation transfer imaging (glycoCEST).

Authors:  Peter C M van Zijl; Craig K Jones; Jimin Ren; Craig R Malloy; A Dean Sherry
Journal:  Proc Natl Acad Sci U S A       Date:  2007-03-05       Impact factor: 11.205

View more
  8 in total

1.  CEST MR-Fingerprinting: Practical considerations and insights for acquisition schedule design and improved reconstruction.

Authors:  Or Perlman; Kai Herz; Moritz Zaiss; Ouri Cohen; Matthew S Rosen; Christian T Farrar
Journal:  Magn Reson Med       Date:  2019-08-09       Impact factor: 4.668

2.  Quantifying amide proton exchange rate and concentration in chemical exchange saturation transfer imaging of the human brain.

Authors:  Hye-Young Heo; Zheng Han; Shanshan Jiang; Michael Schär; Peter C M van Zijl; Jinyuan Zhou
Journal:  Neuroimage       Date:  2019-01-14       Impact factor: 6.556

3.  Deep learning-based classification of preclinical breast cancer tumor models using chemical exchange saturation transfer magnetic resonance imaging.

Authors:  Chongxue Bie; Yuguo Li; Yang Zhou; Zaver M Bhujwalla; Xiaolei Song; Guanshu Liu; Peter C M van Zijl; Nirbhay N Yadav
Journal:  NMR Biomed       Date:  2021-10-19       Impact factor: 4.044

Review 4.  Molecular fMRI of neurochemical signaling.

Authors:  He Wei; Abigail M Frey; Alan Jasanoff
Journal:  J Neurosci Methods       Date:  2021-09-29       Impact factor: 2.390

5.  Glutamate Chemical Exchange Saturation Transfer (GluCEST) Magnetic Resonance Imaging in Pre-clinical and Clinical Applications for Encephalitis.

Authors:  Yanlong Jia; Yanzi Chen; Kuan Geng; Yan Cheng; Yan Li; Jinming Qiu; Huaidong Huang; Runrun Wang; Yunping Zhang; Renhua Wu
Journal:  Front Neurosci       Date:  2020-07-28       Impact factor: 4.677

6.  Magnetic Resonance pH Imaging in Stroke - Combining the Old With the New.

Authors:  James R Larkin; Lee Sze Foo; Brad A Sutherland; Alexandre Khrapitchev; Yee Kai Tee
Journal:  Front Physiol       Date:  2022-02-03       Impact factor: 4.566

Review 7.  Emerging MR Imaging and Spectroscopic Methods to Study Brain Tumor Metabolism.

Authors:  Manoj Kumar; Ravi Prakash Reddy Nanga; Gaurav Verma; Neil Wilson; Jean Christophe Brisset; Kavindra Nath; Sanjeev Chawla
Journal:  Front Neurol       Date:  2022-03-16       Impact factor: 4.003

8.  Brain Amide Proton Transfer Imaging of Rat With Alzheimer's Disease Using Saturation With Frequency Alternating RF Irradiation Method.

Authors:  Runrun Wang; Peidong Chen; Zhiwei Shen; Guisen Lin; Gang Xiao; Zhuozhi Dai; Bingna Zhang; Yuanfeng Chen; Lihua Lai; Xiaodan Zong; Yan Li; Yanyan Tang; Renhua Wu
Journal:  Front Aging Neurosci       Date:  2019-08-22       Impact factor: 5.750

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.