A comparative study of the tissue-destroying effect of the laser and electrocoagulation.

W Matek1, H D Reidenbach, A Wittmann, L Beierlein, P Hermanek.   

Abstract

The effect of the laser on compact, glandular tissue at the dosage employed for the local palliative treatment of tumors, can largely be mimicked with the aid of high-frequency current (HF-current), applied with the aid of an electro-hydro-thermo-probe: The experiments described in the present study were performed on the livers of 70 male Wistar rats. The laser was applied for 2 seconds at an output of 80 J at a distance to the tissue of 0.5 cm. In the first stage, in the acute experiment, the effect of the HF-current was matched to that of the laser by varying the modulated and unmodulated current components. It was found that the depths of penetration into the tissue at the given laser settings could be achieved with modulated HF-current (so-called coagulation current) at an output of more than 72 watts (equipment setting K 10) coagulation being performed for 10 seconds. The admixture of modulated HF-current (so-called cutting current) reduces the depth of penetration into the tissue. In the first 5 days, the depth of penetration increases after both laser irradiation and HF-coagulation, by a factor of 2 to 3. With respect to the depths of penetration (DP), the scatter ranges, and the histological changes, no difference is to be seen between laser and HF lesions: Laser DP = 5.7 mm (confidence range: 4.4-7.0 mm); HF DP (equipment setting K 10) = 4.8 mm (confidence range: 3.6-5.4 mm).(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1989        PMID: 2917534     DOI: 10.1055/s-2007-1012890

Source DB:  PubMed          Journal:  Endoscopy        ISSN: 0013-726X            Impact factor:   10.093


  3 in total

1.  Temperature safety profile of laparoscopic devices: Harmonic ACE (ACE), Ligasure V (LV), and plasma trisector (PT).

Authors:  F J Kim; M F Chammas; E Gewehr; M Morihisa; F Caldas; E Hayacibara; M Baptistussi; F Meyer; A C Martins
Journal:  Surg Endosc       Date:  2007-11-20       Impact factor: 4.584

2.  Lateral thermal spread induced by energy devices: a porcine model to evaluate the influence on the recurrent laryngeal nerve.

Authors:  Masaru Hayami; Masayuki Watanabe; Shinji Mine; Yu Imamura; Akihiko Okamura; Masami Yuda; Kotaro Yamashita; Tasuku Toihata; Yoshiaki Shoji; Naoki Ishizuka
Journal:  Surg Endosc       Date:  2019-03-07       Impact factor: 4.584

3.  Steam induced by the activation of energy devices under a wet condition may cause thermal injury.

Authors:  Masaru Hayami; Masayuki Watanabe; Shinji Mine; Yu Imamura; Akihiko Okamura; Masami Yuda; Kotaro Yamashita; Yoshiaki Shoji; Tasuku Toihata; Ryotaro Kozuki; Naoki Ishizuka
Journal:  Surg Endosc       Date:  2019-12-06       Impact factor: 4.584