Literature DB >> 2917433

Roentgenographic changes in proximal femoral dimensions due to hip rotation.

A L Bell1, R A Brand.   

Abstract

Three human adult femurs were examined using anteroposterior (AP) roentgenograms in anatomical position and in 15 degrees, 30 degrees, and 45 degrees of internal and external rotation. Relatively small (15 degrees or less) amounts of femoral rotation can cause significant changes in proximal femoral dimensions on supine AP hip roentgenograms, and the magnitude of these changes increases with rotation. Fifteen degrees of rotation can change it by almost 3 mm. These changes are comparable to the medullary canal expansion of a normal adult femur over a five- to ten-year period. These changes in measured proximal femoral dimensions with rotation necessitate either an improved roentgenographic technique or precise rotational matching of standard supine roentgenograms to obtain accurate measurements of their changes over time.

Entities:  

Mesh:

Year:  1989        PMID: 2917433

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  6 in total

1.  Increase of cortical bone after a cementless long stem in periprosthetic fractures.

Authors:  Eduardo García-Rey; Eduardo García-Cimbrelo; Ana Cruz-Pardos; Rosário Madero
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

2.  Reliability of overcoverage parameters with varying morphologic pincer features: comparison of EOS® and radiography.

Authors:  Shafagh Monazzam; Mandar Agashe; Harish S Hosalkar
Journal:  Clin Orthop Relat Res       Date:  2013-05-09       Impact factor: 4.176

3.  Gluteus Maximus Transfer following Total Hip Arthroplasty Does Not Improve Abductor Moment: A Case-Control Gait Analysis Study of 15 Patients with Gluteus Medius Disruption.

Authors:  Roland Zügner; Natalie Hjelmberg; Ola Rolfson; Christer Strömberg; Tuuli Saari
Journal:  J Clin Med       Date:  2022-06-02       Impact factor: 4.964

4.  Does femoral rotation influence anteroposterior alpha angle, lateral center-edge angle, and medial proximal femoral angle? A pilot study.

Authors:  Shafagh Monazzam; James D Bomar; Mandar Agashe; Harish S Hosalkar
Journal:  Clin Orthop Relat Res       Date:  2012-11-21       Impact factor: 4.176

5.  Proximal Femoral Bone Regeneration After an Uncemented Hydroxyapatite-coated Long-stem in Revision Hip Surgery.

Authors:  José Cordero-Ampuero; Eduardo Garcia-Rey; Eduardo Garcia-Cimbrelo
Journal:  Open Orthop J       Date:  2018-03-30

6.  Different reliability of instrumented gait analysis between patients with unilateral hip osteoarthritis, unilateral hip prosthesis and healthy controls.

Authors:  Roland Zügner; Roy Tranberg; Vera Lisovskaja; Johan Kärrholm
Journal:  BMC Musculoskelet Disord       Date:  2018-07-18       Impact factor: 2.362

  6 in total