Literature DB >> 2916032

Hepatic neoplasia: breath-hold MR imaging.

M L Winkler1, R F Thoeni, N Luh, L Kaufman, A R Margulis.   

Abstract

Twenty-seven patients with hepatic neoplasms were prospectively examined at 0.35 T with multisection magnetic resonance (MR) imaging during a single breath hold. The procedures included a spin-echo (SE) sequence with a repetition time (TR) of 250 or 125 msec and an echo time (TE) of 15 msec (TR/TE = 250 or 125/15) and gradient-echo (GRE) partial-flip sequences at 250 or 125/20 in phase and 250 or 125/12 out of phase (flip angle of 70 degrees). These procedures were compared with conventional multiacquisition sequences at SE 250/15 (n = 8) in the same patients. GRE partial-flip sequences with a large flip angle provided the optimum combination of contrast and signal-to-noise ratio for imaging hepatic neoplasms, with a signal-difference-to-noise ratio that for in-phase images was 93% greater and for out-of-phase images was 53% greater than that of the SE images. The use of in-phase TEs was preferable to maintain tissue contrast, and presaturation pulses were employed to eliminate vascular pulsation artifacts. All breath-hold procedures provided suppression of motion artifacts superior to that of the short TR, short TE multiacquisition SE imaging. Such sequences should become indispensable for MR imaging of the upper abdomen.

Entities:  

Mesh:

Year:  1989        PMID: 2916032     DOI: 10.1148/radiology.170.3.2916032

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  6 in total

1.  Fast spin-echo imaging of the abdomen during breath-holding: an alternative to RASE and other fast imaging techniques.

Authors:  R C Nelson; J L Chezmar
Journal:  Gastrointest Radiol       Date:  1992

Review 2.  Ultra-high-speed MR imaging.

Authors:  C P Davis; G C McKinnon; J F Debatin; G K von Schulthess
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

3.  Breathhold imaging of the upper abdomen using a circular polarized-array coil: comparison with standard body coil imaging.

Authors:  J Gauger; N G Holzknecht; C A Lackerbauer; H Sittek; K E Fiedler; R Petsch; M Reiser
Journal:  MAGMA       Date:  1996-06       Impact factor: 2.310

4.  Breath-hold MR imaging of focal liver lesions: comparison of fast and ultrasound techniques.

Authors:  J Gaa; H Fischer; G Laub; M Georgi
Journal:  Eur Radiol       Date:  1996       Impact factor: 5.315

5.  Liver MR imaging: comparison of respiratory triggered fast spin echo with T2-weighted spin-echo and inversion recovery.

Authors:  M T Keogan; C E Spritzer; E K Paulson; S S Paine; L Harris; J L Dahlke; J R MacFall
Journal:  Abdom Imaging       Date:  1996 Sep-Oct

6.  Liver lesion detection: comparison between excitation-spoiling fat suppression and regular spin-echo at 1.5T.

Authors:  R C Semelka; H Hricak; K G Bis; W C Werthmuller; C B Higgins
Journal:  Abdom Imaging       Date:  1993
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.