Literature DB >> 2911141

Does compliance mismatch alone cause neointimal hyperplasia?

S P Okuhn1, D P Connelly, N Calakos, L Ferrell, M X Pan, J Goldstone.   

Abstract

To define the relationship between compliance mismatch and the development of neointimal hyperplasia, one 3 cm segment of common iliac artery was externally banded in seven dogs, thereby fixing the arterial diameter at end diastole. To quantify compliance, end-diastole diameter and its change with pulse pressure were measured by induction angiometry. This technique uses intravascular soft trifilar wire probes introduced through distally placed polytetrafluoroethylene sidearms. Compliance was checked in the banded and contralateral undissected unbanded control iliac arteries at 3 and 6 months, at which times the vessels were fixed by perfusion, excised, and examined histologically. Sustained (6-month) compliance mismatch was successfully induced within the banded segments (p less than 0.0001), and no compliance mismatch was seen in the control segments (p = 0.357). The intima of all banded vessels was virtually indistinguishable from that in controls grossly and histologically. Mild focal intimal thickening, less than 3 cell layers thick involving less than 5% of the vessel circumference, was typically seen in both banded and control vessels (range 6.57 +/- 6.80 micron to 38.86 +/- 57.16 micron). In marked contrast, at the sites of the polytetrafluoroethylene-to-femoral artery anastomosis, near-occlusive neointimal hyperplasia (1714 +/- 415.47 micron) was seen in all animals. Residual lumen area in the banded and control vessels was only minimally abnormal (range 98.65% +/- 2.18% to 99.96% +/- 0.08%). These data indicate that compliance mismatch alone is an insufficient stimulus for the development of neointimal hyperplasia in the canine model.

Entities:  

Mesh:

Year:  1989        PMID: 2911141

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  7 in total

1.  Construction of tissue-engineered small-diameter vascular grafts in fibrin scaffolds in 30 days.

Authors:  Liqiong Gui; Michael J Boyle; Yishai M Kamin; Angela H Huang; Barry C Starcher; Cheryl A Miller; Michael J Vishnevetsky; Laura E Niklason
Journal:  Tissue Eng Part A       Date:  2014-02-06       Impact factor: 3.845

2.  Mechanical property characterization of electrospun recombinant human tropoelastin for vascular graft biomaterials.

Authors:  Kathryn A McKenna; Monica T Hinds; Rebecca C Sarao; Ping-Cheng Wu; Cheryl L Maslen; Robert W Glanville; Darcie Babcock; Kenton W Gregory
Journal:  Acta Biomater       Date:  2011-08-06       Impact factor: 8.947

3.  Physiologic compliance in engineered small-diameter arterial constructs based on an elastomeric substrate.

Authors:  Peter M Crapo; Yadong Wang
Journal:  Biomaterials       Date:  2009-12-03       Impact factor: 12.479

4.  Effect of decellularization protocol on the mechanical behavior of porcine descending aorta.

Authors:  John C Fitzpatrick; Peter M Clark; Franco M Capaldi
Journal:  Int J Biomater       Date:  2010-07-04

5.  Effect of pore size and spacing on neovascularization of a biodegradble shape memory polymer perivascular wrap.

Authors:  Timothy C Boire; Lauren E Himmel; Fang Yu; Christy M Guth; Bryan R Dollinger; Thomas A Werfel; Daniel A Balikov; Craig L Duvall
Journal:  J Biomed Mater Res A       Date:  2020-07-04       Impact factor: 4.854

Review 6.  Coronary artery bypass grafting hemodynamics and anastomosis design: a biomedical engineering review.

Authors:  Dhanjoo N Ghista; Foad Kabinejadian
Journal:  Biomed Eng Online       Date:  2013-12-13       Impact factor: 2.819

7.  Customizable modification of banding with external stenting for arteriovenous fistula flow reduction.

Authors:  Alexandros Mallios; Antoine Gaudin; Alexandra Hauguel; Romain de Blic; Benoit Boura; William C Jennings
Journal:  J Vasc Surg Cases Innov Tech       Date:  2022-01-27
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.