Literature DB >> 19962188

Physiologic compliance in engineered small-diameter arterial constructs based on an elastomeric substrate.

Peter M Crapo1, Yadong Wang.   

Abstract

Compliance mismatch is a significant challenge to long-term patency in small-diameter bypass grafts because it causes intimal hyperplasia and ultimately graft occlusion. Current engineered grafts are typically stiff with high burst pressure but low compliance and low elastin expression. We postulated that engineering small arteries on elastomeric scaffolds under dynamic mechanical stimulation would result in strong and compliant arterial constructs. This study compares properties of engineered arterial constructs based on biodegradable polyester scaffolds composed of either rigid poly(lactide-co-glycolide) (PLGA) or elastomeric poly(glycerol sebacate) (PGS). Adult baboon arterial smooth muscle cells (SMCs) were cultured in vitro for 10 days in tubular, porous scaffolds. Scaffolds were significantly stronger after culture regardless of material, but the elastic modulus of PLGA constructs was an order of magnitude greater than that of porcine carotid arteries and PGS constructs. Deformation was elastic in PGS constructs and carotid arteries but plastic in PLGA constructs. Compliance of arteries and PGS constructs were equivalent at pressures tested. Altering scaffold material from PLGA to PGS significantly decreased collagen content and significantly increased insoluble elastin content in constructs without affecting soluble elastin concentration in the culture medium. PLGA constructs contained no appreciable insoluble elastin. This research demonstrates that: (1) substrate stiffness directly affects in vitro tissue development and mechanical properties; (2) rigid materials likely inhibit elastin incorporation into the extracellular matrix of engineered arterial tissues; and (3) grafts with physiologic compliance and significant elastin content can be engineered in vitro after only days of cell culture. (c) 2009 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19962188      PMCID: PMC2813924          DOI: 10.1016/j.biomaterials.2009.11.035

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  47 in total

1.  Novel vascular graft grown within recipient's own peritoneal cavity.

Authors:  J H Campbell; J L Efendy; G R Campbell
Journal:  Circ Res       Date:  1999 Dec 3-17       Impact factor: 17.367

Review 2.  Viscoelasticity of the vessel wall: the role of collagen and elastic fibers.

Authors:  F H Silver; I Horvath; D J Foran
Journal:  Crit Rev Biomed Eng       Date:  2001

3.  Seamless tubular poly(glycerol sebacate) scaffolds: high-yield fabrication and potential applications.

Authors:  Peter M Crapo; Jin Gao; Yadong Wang
Journal:  J Biomed Mater Res A       Date:  2008-08       Impact factor: 4.396

Review 4.  Radial artery conduit for coronary revascularization: as good as an internal thoracic artery?

Authors:  Nimesh D Desai; Stephen E Fremes
Journal:  Curr Opin Cardiol       Date:  2007-11       Impact factor: 2.161

5.  Morphologic and mechanical characteristics of engineered bovine arteries.

Authors:  L E Niklason; W Abbott; J Gao; B Klagges; K K Hirschi; K Ulubayram; N Conroy; R Jones; A Vasanawala; S Sanzgiri; R Langer
Journal:  J Vasc Surg       Date:  2001-03       Impact factor: 4.268

Review 6.  Optimal revascularization strategies for multivessel coronary artery disease.

Authors:  Joost Daemen; Patrick W Serruys
Journal:  Curr Opin Cardiol       Date:  2006-11       Impact factor: 2.161

7.  Functional small-diameter neovessels created using endothelial progenitor cells expanded ex vivo.

Authors:  S Kaushal; G E Amiel; K J Guleserian; O M Shapira; T Perry; F W Sutherland; E Rabkin; A M Moran; F J Schoen; A Atala; S Soker; J Bischoff; J E Mayer
Journal:  Nat Med       Date:  2001-09       Impact factor: 53.440

8.  Co-expression of elastin and collagen leads to highly compliant engineered blood vessels.

Authors:  Jin Gao; Peter Crapo; Robert Nerem; Yadong Wang
Journal:  J Biomed Mater Res A       Date:  2008-06-15       Impact factor: 4.396

9.  Poly(glycerol sebacate) supports the proliferation and phenotypic protein expression of primary baboon vascular cells.

Authors:  Jin Gao; Ann E Ensley; Robert M Nerem; Yadong Wang
Journal:  J Biomed Mater Res A       Date:  2007-12-15       Impact factor: 4.396

10.  Heart disease and stroke statistics--2008 update: a report from the American Heart Association Statistics Committee and Stroke Statistics Subcommittee.

Authors:  Wayne Rosamond; Katherine Flegal; Karen Furie; Alan Go; Kurt Greenlund; Nancy Haase; Susan M Hailpern; Michael Ho; Virginia Howard; Brett Kissela; Bret Kissela; Steven Kittner; Donald Lloyd-Jones; Mary McDermott; James Meigs; Claudia Moy; Graham Nichol; Christopher O'Donnell; Veronique Roger; Paul Sorlie; Julia Steinberger; Thomas Thom; Matt Wilson; Yuling Hong
Journal:  Circulation       Date:  2007-12-17       Impact factor: 29.690

View more
  24 in total

Review 1.  Tissue engineering and regenerative strategies to replicate biocomplexity of vascular elastic matrix assembly.

Authors:  Chris A Bashur; Lavanya Venkataraman; Anand Ramamurthi
Journal:  Tissue Eng Part B Rev       Date:  2012-03-02       Impact factor: 6.389

2.  Fabricating mechanically improved silk-based vascular grafts by solution control of the gel-spinning process.

Authors:  Maria Rodriguez; Jonathan A Kluge; Daniel Smoot; Matthew A Kluge; Daniel F Schmidt; Christopher R Paetsch; Peter S Kim; David L Kaplan
Journal:  Biomaterials       Date:  2019-10-23       Impact factor: 12.479

3.  Tunable Elastomers with an Antithrombotic Component for Cardiovascular Applications.

Authors:  Alexander M Stahl; Yunzhi Peter Yang
Journal:  Adv Healthc Mater       Date:  2018-05-31       Impact factor: 9.933

4.  Substantial expression of mature elastin in arterial constructs.

Authors:  Kee-Won Lee; Donna B Stolz; Yadong Wang
Journal:  Proc Natl Acad Sci U S A       Date:  2011-01-31       Impact factor: 11.205

5.  Electrospun rapamycin-eluting polyurethane fibers for vascular grafts.

Authors:  Jingjia Han; Shady Farah; Abraham J Domb; Peter I Lelkes
Journal:  Pharm Res       Date:  2013-04-09       Impact factor: 4.200

6.  Artificial niche combining elastomeric substrate and platelets guides vascular differentiation of bone marrow mononuclear cells.

Authors:  Wei Wu; Robert Allen; Jin Gao; Yadong Wang
Journal:  Tissue Eng Part A       Date:  2011-05-12       Impact factor: 3.845

7.  Highly elastic and suturable electrospun poly(glycerol sebacate) fibrous scaffolds.

Authors:  Eric M Jeffries; Robert A Allen; Jin Gao; Matt Pesce; Yadong Wang
Journal:  Acta Biomater       Date:  2015-02-14       Impact factor: 8.947

8.  Development and evaluation of elastomeric hollow fiber membranes as small diameter vascular graft substitutes.

Authors:  Ángel E Mercado-Pagán; Yunqing Kang; Michael W Findlay; Yunzhi Yang
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2015-01-15       Impact factor: 7.328

9.  Degradation and erosion mechanisms of bioresorbable porous acellular vascular grafts: an in vitro investigation.

Authors:  Piyusha S Gade; Keewon Lee; Blaise N Pfaff; Yadong Wang; Anne M Robertson
Journal:  J R Soc Interface       Date:  2017-07       Impact factor: 4.118

10.  Embryonic mechanical and soluble cues regulate tendon progenitor cell gene expression as a function of developmental stage and anatomical origin.

Authors:  Jeffrey P Brown; Violet G Finley; Catherine K Kuo
Journal:  J Biomech       Date:  2013-10-30       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.