Omar A Ibrahim1, Doran Drew1, Christopher J Hayes2, William McIntyre3, Colette M Seifer2, Wilma Hopman1, Benedict Glover1, Adrian M Baranchuk4,5. 1. Department of Cardiology, Kingston General Hospital, Queen's University, Kingston, Ontario, Canada. 2. Department of Cardiology, St. Boniface Hospital, University of Manitoba, Winnipeg, Manitoba, Canada. 3. Population Health Research Institute, McMaster University, Hamilton, Ontario, Canada. 4. Department of Cardiology, Kingston General Hospital, Queen's University, Kingston, Ontario, Canada. barancha@kgh.kari.net. 5. Cardiac Electrophysiology and Pacing, Kingston General Hospital, Queen's University, Kingston, Ontario, K7L 2V7, Canada. barancha@kgh.kari.net.
Abstract
PURPOSE: Implantable loop recorders (ILRs) are increasingly being used for ambulatory electrocardiography. We sought to evaluate ILR indications, diagnostic yield, ILR-guided interventions, and complications in two Canadian centers. METHODS: This was a retrospective study using electronic medical records to identify ILR implants at Queen's University and the University of Manitoba. Information was collected on patient characteristics, medications, indication for implant, results of prior investigations, diagnostic outcome, and subsequent management. RESULTS: A total of 540 patients were identified; 386 had completed monitoring at time of analysis. Forty patients were lost to follow-up. Indications were unexplained syncope 84.8%, palpitations 12.8%, and suspected atrial fibrillation 11.7%. For syncope, ILRs documented arrhythmia or conduction disorder in 46%. Most common conditions were asystole/sinus pause (22%), complete heart block (10.4%), and atrial fibrillation (AF) (6.9%). After ILR diagnosis, 39.9% of implanted patients received pacemaker/ICD and 2.7% underwent catheter ablation. For palpitations, ILRs documented arrhythmia or conduction disorder in 60.4%. Most common conditions were AVNRT, AF, complete heart block, and ventricular tachycardia. After diagnosis, 25% underwent catheter ablation and 22.9% received pacemaker/ICD. For suspected AF, AF was diagnosed in 40%. Complications were observed in 3.3% of implanted patients: implant site infection 1.5%, non-infectious implant site pain requiring device removal or pocket revision 1.5%, 0.2% hypertrophic scar, and 0.2% device malfunction. CONCLUSIONS: An ILR has excellent diagnostic yield for syncope, palpitations, and suspected AF, and a considerable proportion of patients undergo ILR-directed interventions following monitoring. ILR implantation is a low-risk procedure.
PURPOSE: Implantable loop recorders (ILRs) are increasingly being used for ambulatory electrocardiography. We sought to evaluate ILR indications, diagnostic yield, ILR-guided interventions, and complications in two Canadian centers. METHODS: This was a retrospective study using electronic medical records to identify ILR implants at Queen's University and the University of Manitoba. Information was collected on patient characteristics, medications, indication for implant, results of prior investigations, diagnostic outcome, and subsequent management. RESULTS: A total of 540 patients were identified; 386 had completed monitoring at time of analysis. Forty patients were lost to follow-up. Indications were unexplained syncope 84.8%, palpitations 12.8%, and suspected atrial fibrillation 11.7%. For syncope, ILRs documented arrhythmia or conduction disorder in 46%. Most common conditions were asystole/sinus pause (22%), complete heart block (10.4%), and atrial fibrillation (AF) (6.9%). After ILR diagnosis, 39.9% of implanted patients received pacemaker/ICD and 2.7% underwent catheter ablation. For palpitations, ILRs documented arrhythmia or conduction disorder in 60.4%. Most common conditions were AVNRT, AF, complete heart block, and ventricular tachycardia. After diagnosis, 25% underwent catheter ablation and 22.9% received pacemaker/ICD. For suspected AF, AF was diagnosed in 40%. Complications were observed in 3.3% of implanted patients: implant site infection 1.5%, non-infectious implant site pain requiring device removal or pocket revision 1.5%, 0.2% hypertrophic scar, and 0.2% device malfunction. CONCLUSIONS: An ILR has excellent diagnostic yield for syncope, palpitations, and suspected AF, and a considerable proportion of patients undergo ILR-directed interventions following monitoring. ILR implantation is a low-risk procedure.
Authors: Win-Kuang Shen; Robert S Sheldon; David G Benditt; Mitchell I Cohen; Daniel E Forman; Zachary D Goldberger; Blair P Grubb; Mohamed H Hamdan; Andrew D Krahn; Mark S Link; Brian Olshansky; Satish R Raj; Roopinder Kaur Sandhu; Dan Sorajja; Benjamin C Sun; Clyde W Yancy Journal: Heart Rhythm Date: 2017-03-09 Impact factor: 6.343
Authors: Philipp Attanasio; Martin Huemer; Lena Loehr; Abdul Shokor Parwani; Leif-Hendrik Boldt; Wilhelm Haverkamp; Alexander Wutzler Journal: Ann Noninvasive Electrocardiol Date: 2015-08-05 Impact factor: 1.468
Authors: Liane A Arcinas; William F McIntyre; Christopher J Hayes; Omar A Ibrahim; Adrian M Baranchuk; Colette M Seifer Journal: Ann Noninvasive Electrocardiol Date: 2019-01-07 Impact factor: 1.468
Authors: P L Vidya; R Ananthakrishnan; Reema Mukherjee; Prafull Sharma; Sudhir Joshi; Soumitra Mohanty Journal: Med J Armed Forces India Date: 2021-03-24
Authors: Jens Cosedis Nielsen; Yenn-Jiang Lin; Marcio Jansen de Oliveira Figueiredo; Alireza Sepehri Shamloo; Alberto Alfie; Serge Boveda; Nikolaos Dagres; Dario Di Toro; Lee L Eckhardt; Kenneth Ellenbogen; Carina Hardy; Takanori Ikeda; Aparna Jaswal; Elizabeth Kaufman; Andrew Krahn; Kengo Kusano; Valentina Kutyifa; Han S Lim; Gregory Y H Lip; Santiago Nava-Townsend; Hui-Nam Pak; Gerardo Rodríguez Diez; William Sauer; Anil Saxena; Jesper Hastrup Svendsen; Diego Vanegas; Marmar Vaseghi; Arthur Wilde; T Jared Bunch; Alfred E Buxton; Gonzalo Calvimontes; Tze-Fan Chao; Lars Eckardt; Heidi Estner; Anne M Gillis; Rodrigo Isa; Josef Kautzner; Philippe Maury; Joshua D Moss; Gi-Byung Nam; Brian Olshansky; Luis Fernando Pava Molano; Mauricio Pimentel; Mukund Prabhu; Wendy S Tzou; Philipp Sommer; Janice Swampillai; Alejandro Vidal; Thomas Deneke; Gerhard Hindricks; Christophe Leclercq Journal: Europace Date: 2020-08-01 Impact factor: 5.214