Dynamic collimator trajectory algorithm for multiple metastases dynamic conformal arc treatment planning.

R Lee MacDonald1, Christopher G Thomas1,2,3,4, Alasdair Syme1,2,3.   

Abstract

PURPOSE: To develop an algorithm for dynamic collimator positioning to optimize beam's eye view (BEV) fitting of targets in dynamic conformal arc (DCA)-based radiotherapy procedures, of particular use in multiple metastases stereotactic radiosurgery procedures.
METHODS: A trajectory algorithm was developed to dynamically modify the angle of the collimator as a function of arc-based control point to provide optimized collimation of target volume(s). Central to this algorithm is a concept denoted herein as "whitespace" defined as any nontarget area in the BEV that is not covered by any collimation system and is open to exposure from the radiation beam. Calculating whitespace at all collimator angles and every control point, a two-dimensional topographical map depicting the tightness-of-fit of the MLC was generated. A bidirectional gradient trajectory algorithm identified a number of candidate trajectories of continuous collimator motion. Minimization of integrated whitespace was used to identify an optimal solution for the navigation of the parameter space. Plans with dynamic collimator trajectories were designed for multiple metastases targets and were compared with fixed collimator angle dynamic conformal arc (DCA) plans and standard VMAT plans.
RESULTS: Algorithm validation was performed on simple test cases with known solutions. The whitespace metric showed a strong correlation (R2 = 0.90) with mean dose to proximal normal tissue. Seventeen cases were studied using our algorithm to generate dynamic conformal arc (DCA) plans with optimized collimator trajectories for three and four target SRS patients and comparing them to DCA plans generated with optimized fixed collimator angles per arc and standard VMAT plans generated via template. Optimized collimator trajectories were found to produce a reduction in monitor units of up to 49.7 ± 5.1% when compared to VMAT across 17 patients, and all organ-at-risk and normal brain metrics were found to be superior or comparable.
CONCLUSION: Dynamic collimator trajectories have the potential to improve DCA deliveries through increased efficiency, especially in the treatment of multiple cranial metastases. Implementation of this technology should not be hindered by mechanical safety considerations as collimator motions do not modify or introduce any new risks of collisions with patients.
© 2017 American Association of Physicists in Medicine.

Entities:  

Keywords:  SRS; dynamic collimator trajectory; dynamic conformal arc; multiple metastases; treatment planning

Mesh:

Year:  2017        PMID: 29094419     DOI: 10.1002/mp.12648

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  A Collimator Setting Optimization Algorithm for Dual-Arc Volumetric Modulated Arc Therapy in Pancreas Stereotactic Body Radiation Therapy.

Authors:  Xinyi Li; Jackie Wu; Manisha Palta; You Zhang; Yang Sheng; Jiahan Zhang; Chunhao Wang
Journal:  Technol Cancer Res Treat       Date:  2019-01-01

2.  Fast stereotactic radiosurgery planning using patient-specific beam angle optimization and automation.

Authors:  Thomas D Mann; Kundan S Thind; Nicolas P Ploquin
Journal:  Phys Imaging Radiat Oncol       Date:  2022-02-26

3.  Sub-arc collimator angle optimization based on the conformity index heatmap for VMAT planning of multiple brain metastases SRS treatments.

Authors:  Jiuling Shen; Zhitao Dai; Jing Yu; Qingqing Yuan; Kailian Kang; Cheng Chen; Hui Liu; Conghua Xie; Xiaoyong Wang
Journal:  Front Oncol       Date:  2022-09-06       Impact factor: 5.738

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.