Literature DB >> 28990436

Acceptability of Implantable Continuous Glucose Monitoring Sensor.

Katharine D Barnard1,2, Jort Kropff3, Pratik Choudhary4, Sankalpa Neupane5, Stephen C Bain6, Christoph Kapitza7, Thomas Forst8, Manuela Link9, Colleen Mdingi10, J Hans DeVries3.   

Abstract

BACKGROUND: Real-time continuous glucose monitoring is associated with significant benefits for diabetes management. Implantable sensors could overcome some challenges reportedly associated with device visibility, psychosocial functioning and sensor durability.
METHODS: A psychosocial assessment was conducted to determine acceptability and impact of an implantable continuous glucose monitoring (CGM) sensor as part of the PRECISE trial. Questionnaires were administered to participants comprising the Diabetes Distress Scale, the CGM impact scale, and bespoke device satisfaction.
RESULTS: Fifty-one participants across the United Kingdom (n = 10) and Germany (n = 41) completed the questionnaires. Of these, 90% had T1D, 50% followed an insulin pump therapy regimen, and 45% of the participants were previous CGM users. CGM Impact Scale results show 86% (n = 44) of participants reported feeling better (14% neutral) about their diabetes control with 90% CGM naïve participants and 81% previous CGM users reporting increased confidence about their diabetes management. Furthermore, 73% (n = 37) felt more safe (27% neutral) while sleeping and 78% (n = 39) more confident (22% neutral) about avoiding serious hypoglycemia. Responses correspond with an average improvement in HbA1c from 7.51 to 7.05 ( P < .0001) over the 90 days use of the CGM. Overall, the system was rated highly on ease of use, convenience and comfort. 84% would choose to be inserted again with 93% of CGM naïve participants (86% previous CGM users) reporting minimized burden of diabetes.
CONCLUSIONS: Implantable CGM devices are acceptable to users and are evaluated favorably. The considerable majority of participants (93% of first time users and 77% previous CGM users) would like to continue using the system to help manage their diabetes more effectively.

Entities:  

Keywords:  continuous glucose monitoring; implantable; psychosocial; type 1 diabetes

Mesh:

Substances:

Year:  2017        PMID: 28990436      PMCID: PMC6154244          DOI: 10.1177/1932296817735123

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  12 in total

1.  Psychosocial factors associated with use of continuous glucose monitoring.

Authors:  M D Ritholz; A Atakov-Castillo; M Beste; E A Beverly; A Leighton; K Weinger; H Wolpert
Journal:  Diabet Med       Date:  2010-09       Impact factor: 4.359

2.  Patient-reported outcomes and continuous glucose monitoring: can we do better with artificial pancreas devices?

Authors:  Katharine D Barnard; Thomas Kubiak; Norbert Hermanns; Lutz Heinemann
Journal:  Diabetes Care       Date:  2015-05       Impact factor: 19.112

Review 3.  Is continuous glucose monitoring (CGM) for everyone? To whom should CGM be prescribed and how?

Authors:  J-P Riveline
Journal:  Diabetes Metab       Date:  2011-12       Impact factor: 6.041

4.  Development of a New Measure for Assessing Glucose Monitoring Device-Related Treatment Satisfaction and Quality of Life.

Authors:  William H Polonsky; Lawrence Fisher; Danielle Hessler; Steven V Edelman
Journal:  Diabetes Technol Ther       Date:  2015-04-29       Impact factor: 6.118

5.  Enhancing self-efficacy for optimized patient outcomes through the theory of symptom self-management.

Authors:  Amy J Hoffman
Journal:  Cancer Nurs       Date:  2013 Jan-Feb       Impact factor: 2.592

6.  Development of a brief diabetes distress screening instrument.

Authors:  Lawrence Fisher; Russell E Glasgow; Joseph T Mullan; Marilyn M Skaff; William H Polonsky
Journal:  Ann Fam Med       Date:  2008 May-Jun       Impact factor: 5.166

7.  Real-time continuous glucose monitoring among participants in the T1D Exchange clinic registry.

Authors:  Jenise C Wong; Nicole C Foster; David M Maahs; Dan Raghinaru; Richard M Bergenstal; Andrew J Ahmann; Anne L Peters; Bruce W Bode; Grazia Aleppo; Irl B Hirsch; Lora Kleis; H Peter Chase; Stephanie N DuBose; Kellee M Miller; Roy W Beck; Saleh Adi
Journal:  Diabetes Care       Date:  2014-07-10       Impact factor: 19.112

8.  Recovery of hypoglycemia awareness in long-standing type 1 diabetes: a multicenter 2 × 2 factorial randomized controlled trial comparing insulin pump with multiple daily injections and continuous with conventional glucose self-monitoring (HypoCOMPaSS).

Authors:  Stuart A Little; Lalantha Leelarathna; Emma Walkinshaw; Horng Kai Tan; Olivia Chapple; Alexandra Lubina-Solomon; Thomas J Chadwick; Shalleen Barendse; Deborah D Stocken; Catherine Brennand; Sally M Marshall; Ruth Wood; Jane Speight; David Kerr; Daniel Flanagan; Simon R Heller; Mark L Evans; James A M Shaw
Journal:  Diabetes Care       Date:  2014-05-22       Impact factor: 19.112

9.  Glycaemic control in type 1 diabetes during real time continuous glucose monitoring compared with self monitoring of blood glucose: meta-analysis of randomised controlled trials using individual patient data.

Authors:  John C Pickup; Suzanne C Freeman; Alex J Sutton
Journal:  BMJ       Date:  2011-07-07

10.  Effectiveness of continuous glucose monitoring in a clinical care environment: evidence from the Juvenile Diabetes Research Foundation continuous glucose monitoring (JDRF-CGM) trial.

Authors: 
Journal:  Diabetes Care       Date:  2009-10-16       Impact factor: 19.112

View more
  5 in total

Review 1.  Use of continuous glucose monitoring in obesity research: A scoping review.

Authors:  Elizabeth Hegedus; Sarah-Jeanne Salvy; Choo Phei Wee; Monica Naguib; Jennifer K Raymond; D Steven Fox; Alaina P Vidmar
Journal:  Obes Res Clin Pract       Date:  2021-09-02       Impact factor: 5.214

2.  Hydrogel Microdomain Encapsulation of Stable Functionalized Silver Nanoparticles for SERS pH and Urea Sensing.

Authors:  Alexander Quinn; Yil-Hwan You; Michael J McShane
Journal:  Sensors (Basel)       Date:  2019-08-12       Impact factor: 3.576

3.  A Prospective Multicenter Evaluation of the Accuracy of a Novel Implanted Continuous Glucose Sensor: PRECISE II.

Authors:  Mark P Christiansen; Leslie J Klaff; Ronald Brazg; Anna R Chang; Carol J Levy; David Lam; Douglas S Denham; George Atiee; Bruce W Bode; Steven J Walters; Lynne Kelley; Timothy S Bailey
Journal:  Diabetes Technol Ther       Date:  2018-01-30       Impact factor: 6.118

4.  Continuous Glucose Monitoring in Resource-Constrained Settings for Hypoglycaemia Detection: Looking at the Problem from the Other Side of the Coin.

Authors:  Rubao Bila; Rosauro Varo; Lola Madrid; Antonio Sitoe; Quique Bassat
Journal:  Biosensors (Basel)       Date:  2018-04-25

5.  Implantable and transcutaneous continuous glucose monitoring system: a randomized cross over trial comparing accuracy, efficacy and acceptance.

Authors:  F Boscari; M Vettoretti; F Cavallin; A M L Amato; A Uliana; V Vallone; A Avogaro; A Facchinetti; D Bruttomesso
Journal:  J Endocrinol Invest       Date:  2021-07-01       Impact factor: 4.256

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.