Literature DB >> 28987293

Society of Family Planning Guidelines: Postplacental insertion of intrauterine devices.

Amy K Whitaker1, Beatrice A Chen2.   

Abstract

Postplacental intrauterine device (IUD) placement, defined as IUD placement within 10 min after delivery of the placenta, is an appealing strategy for increasing access to postpartum IUDs because it does not require a separate postpartum visit. These guidelines present an evidence-based assessment of postplacental IUD placement after vaginal and cesarean delivery. Postplacental IUD insertion is safe and does not have higher risks of complications than interval insertion. Most studies find that the risk of IUD expulsion is higher after postplacental insertion than after interval insertion for both vaginal and cesarean deliveries. Most studies find higher rates of expulsion after vaginal delivery than after cesarean delivery. However, expulsion rates vary widely across studies, without clear evidence about the factors that may influence expulsion. In settings where replacement of expelled IUDs is available, patient populations with low rates of return for the postpartum visit are most likely to benefit from provision of postplacental IUD placement with appropriate counseling about risks and benefits.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Contraception; IUD expulsion; Intrauterine device; Intrauterine system; Levonorgestrel; Postpartum IUD; Postpartum contraception; Postplacental IUD

Mesh:

Year:  2017        PMID: 28987293     DOI: 10.1016/j.contraception.2017.09.014

Source DB:  PubMed          Journal:  Contraception        ISSN: 0010-7824            Impact factor:   3.375


  7 in total

1.  Six-month expulsion of postplacental copper intrauterine devices placed after vaginal delivery.

Authors:  Elizabeth P Gurney; Sarita Sonalkar; Arden McAllister; Mary D Sammel; Courtney A Schreiber
Journal:  Am J Obstet Gynecol       Date:  2018-06-02       Impact factor: 8.661

2.  Expulsion of intrauterine devices after postpartum placement by timing of placement, delivery type, and intrauterine device type: a systematic review and meta-analysis.

Authors:  Sarah H Averbach; Yokabed Ermias; Gary Jeng; Kathryn M Curtis; Maura K Whiteman; Erin Berry-Bibee; Denise J Jamieson; Polly A Marchbanks; Naomi K Tepper; Tara C Jatlaoui
Journal:  Am J Obstet Gynecol       Date:  2020-03-03       Impact factor: 8.661

3.  Intrauterine Device Expulsion After Postpartum Placement: A Systematic Review and Meta-analysis.

Authors:  Tara C Jatlaoui; Maura K Whiteman; Gary Jeng; Naomi K Tepper; Erin Berry-Bibee; Denise J Jamieson; Polly A Marchbanks; Kathryn M Curtis
Journal:  Obstet Gynecol       Date:  2018-10       Impact factor: 7.661

4.  Do Expectant Mothers' Breastfeeding Plans Influence Provider Prenatal Contraceptive Counseling?

Authors:  Lydia Furman; Maria Shaker; Kavita Shah Arora
Journal:  J Hum Lact       Date:  2019-09-12       Impact factor: 2.219

Review 5.  Postpartum intrauterine device placement: a patient-friendly option.

Authors:  Carrie Cwiak; Sarah Cordes
Journal:  Contracept Reprod Med       Date:  2018-04-15

6.  Delivering postpartum family planning services in Nepal: are providers supportive?

Authors:  Mahesh C Puri; Manju Maharjan; Erin Pearson; Elina Pradhan; Yasaswi Dhungel; Aayush Khadka; Iqbal H Shah
Journal:  BMC Health Serv Res       Date:  2018-12-06       Impact factor: 2.655

7.  Postplacental Insertion of Levonorgestrel Intrauterine System Versus Copper Intrauterine Device: A Prospective Study.

Authors:  Elsayed Elshamy; Ahmed Nofal; Dalia Ibrrahim
Journal:  J Obstet Gynaecol India       Date:  2021-01-20
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.