Britta Berg-Johansen1,2, Misung Han3, Aaron J Fields1, Ellen C Liebenberg1, Brandon J Lim1, Peder Ez Larson2,3, Cigdem Gunduz-Demir4,5, Galateia J Kazakia3, Roland Krug3, Jeffrey C Lotz1,2. 1. Department of Orthopaedic Surgery, University of California, San Francisco, CA. 2. Department of Bioengineering, UC Berkeley/UCSF Joint Program in Bioengineering, Berkeley, CA. 3. Department of Radiology and Biomedical Imaging, University of California, San Francisco, CA. 4. Department of Computer Engineering, Bilkent University, Ankara, Turkey. 5. Neuroscience Graduate Program, Bilkent University, Ankara, Turkey.
Abstract
STUDY DESIGN: A magnetic resonance imaging study of human cadaver spines. OBJECTIVE: To investigate associations between cartilage endplate (CEP) thickness and disc degeneration. SUMMARY OF BACKGROUND DATA: Damage to the CEP is associated with spinal injury and back pain. However, CEP morphology and its association with disc degeneration have not been well characterized. METHODS: Ten lumbar motion segments with varying degrees of disc degeneration were harvested from six cadaveric spines and scanned with magnetic resonance imaging in the sagittal plane using a T2-weighted two-dimensional (2D) sequence, a three-dimensional (3D) ultrashort echo-time (UTE) imaging sequence, and a 3D T1ρ mapping sequence. CEP thicknesses were calculated from 3D UTE image data using a custom, automated algorithm, and these values were validated against histology measurements. Pfirrmann grades and T1ρ values in the disc were assessed and correlated with CEP thickness. RESULTS: The mean CEP thickness calculated from UTE images was 0.74 ± 0.04 mm. Statistical comparisons between histology and UTE-derived measurements of CEP thickness showed significant agreement, with the mean difference not significantly different from zero (P = 0.32). Within-disc variation of T1ρ (standard deviation) was significantly lower for Pfirrmann grade 4 than Pfirrmann grade 3 (P < 0.05). Within-disc variation of T1ρ and adjacent CEP thickness heterogeneity (coefficient of variation) had a significant negative correlation (r = -0.65, P = 0.04). The standard deviation of T1ρand the mean CEP thickness showed a moderate positive correlation (r = 0.40, P = 0.26). CONCLUSION: This study demonstrates that quantitative measurements of CEP thickness measured from UTE magnetic resonance imaging are associated with disc degeneration. Our results suggest that variability in CEP thickness and T1ρ, rather than their mean values, may serve as valuable diagnostic markers for disc degeneration. LEVEL OF EVIDENCE: N/A.
STUDY DESIGN: A magnetic resonance imaging study of human cadaver spines. OBJECTIVE: To investigate associations between cartilage endplate (CEP) thickness and disc degeneration. SUMMARY OF BACKGROUND DATA: Damage to the CEP is associated with spinal injury and back pain. However, CEP morphology and its association with disc degeneration have not been well characterized. METHODS: Ten lumbar motion segments with varying degrees of disc degeneration were harvested from six cadaveric spines and scanned with magnetic resonance imaging in the sagittal plane using a T2-weighted two-dimensional (2D) sequence, a three-dimensional (3D) ultrashort echo-time (UTE) imaging sequence, and a 3D T1ρ mapping sequence. CEP thicknesses were calculated from 3D UTE image data using a custom, automated algorithm, and these values were validated against histology measurements. Pfirrmann grades and T1ρ values in the disc were assessed and correlated with CEP thickness. RESULTS: The mean CEP thickness calculated from UTE images was 0.74 ± 0.04 mm. Statistical comparisons between histology and UTE-derived measurements of CEP thickness showed significant agreement, with the mean difference not significantly different from zero (P = 0.32). Within-disc variation of T1ρ (standard deviation) was significantly lower for Pfirrmann grade 4 than Pfirrmann grade 3 (P < 0.05). Within-disc variation of T1ρ and adjacent CEP thickness heterogeneity (coefficient of variation) had a significant negative correlation (r = -0.65, P = 0.04). The standard deviation of T1ρand the mean CEP thickness showed a moderate positive correlation (r = 0.40, P = 0.26). CONCLUSION: This study demonstrates that quantitative measurements of CEP thickness measured from UTE magnetic resonance imaging are associated with disc degeneration. Our results suggest that variability in CEP thickness and T1ρ, rather than their mean values, may serve as valuable diagnostic markers for disc degeneration. LEVEL OF EVIDENCE: N/A.
Authors: K Luoma; H Riihimäki; R Luukkonen; R Raininko; E Viikari-Juntura; A Lamminen Journal: Spine (Phila Pa 1976) Date: 2000-02-15 Impact factor: 3.468
Authors: Gabrielle Blumenkrantz; Jin Zuo; Xiaojuan Li; John Kornak; Thomas M Link; Sharmila Majumdar Journal: Magn Reson Med Date: 2010-05 Impact factor: 4.668
Authors: Stefan Dudli; David C Sing; Serena S Hu; Sigurd H Berven; Shane Burch; Vedat Deviren; Ivan Cheng; Bobby K B Tay; Todd F Alamin; Ma Agnes Martinez Ith; Eric M Pietras; Jeffrey C Lotz Journal: Eur Spine J Date: 2017-01-31 Impact factor: 3.134
Authors: Polly Lama; Uruj Zehra; Christian Balkovec; Henry A Claireaux; Luke Flower; Ian J Harding; Patricia Dolan; Michael A Adams Journal: Eur Spine J Date: 2014-06-20 Impact factor: 3.134
Authors: J Wong; S L Sampson; H Bell-Briones; A Ouyang; A A Lazar; J C Lotz; A J Fields Journal: Osteoarthritis Cartilage Date: 2019-02-02 Impact factor: 6.576
Authors: Benedikt J Schwaiger; Charlotte Schneider; Sophia Kronthaler; Florian T Gassert; Christof Böhm; Daniela Pfeiffer; Thomas Baum; Jan S Kirschke; Dimitrios C Karampinos; Marcus R Makowski; Klaus Woertler; Markus Wurm; Alexandra S Gersing Journal: Eur Radiol Date: 2021-01-14 Impact factor: 5.315