Literature DB >> 34622996

Reproducibility of 7-T brain spectroscopy using an ultrashort echo time STimulated Echo Acquisition Mode sequence and automated voxel repositioning.

Meredith A Reid1,2, Martha R Forloines3, Nouha Salibi4.   

Abstract

Establishing the reproducibility of brain MRS is important for clinical studies so that researchers can evaluate changes in metabolites due to treatment or the course of a disease and better understand the brain in healthy and disordered states. Prior 7-T MRS reproducibility studies using the stimulated echo acquisition mode (STEAM) sequence have focused on the anterior cingulate cortex or posterior cingulate cortex and precuneus. The purpose of this study was to evaluate the reproducibility of metabolite measurements in the dorsolateral prefrontal cortex (DLPFC) using an ultrashort echo time (TE) STEAM sequence and automated voxel repositioning. Spectra were acquired during two scan sessions from nine subjects using the AutoAlign method for voxel repositioning. Reproducibility was evaluated with coefficients of variation (CVs) and percentage differences. The mean intrasubject CVs were less than 6% for the major metabolites glutamate, N-acetylaspartate, total creatine, total choline, and myo-inositol. The mean CVs were less than 20% for the smaller signals of GABA, glutamine, glutathione, and taurine. These results indicate that 7-T MRS using a STEAM sequence with ultrashort TE and automated voxel repositioning provides excellent reproducibility of metabolites in the DLPFC.
© 2021 John Wiley & Sons, Ltd.

Entities:  

Keywords:  7 T; STEAM; dorsolateral prefrontal cortex; magnetic resonance spectroscopy; reproducibility

Mesh:

Substances:

Year:  2021        PMID: 34622996      PMCID: PMC8862634          DOI: 10.1002/nbm.4631

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  56 in total

1.  A quantitative meta-analysis of neurocognitive functioning in posttraumatic stress disorder.

Authors:  J Cobb Scott; Georg E Matt; Kristen M Wrocklage; Cassandra Crnich; Jessica Jordan; Steven M Southwick; John H Krystal; Brian C Schweinsburg
Journal:  Psychol Bull       Date:  2014-11-03       Impact factor: 17.737

Review 2.  Issues of spectral quality in clinical 1H-magnetic resonance spectroscopy and a gallery of artifacts.

Authors:  Roland Kreis
Journal:  NMR Biomed       Date:  2004-10       Impact factor: 4.044

3.  Real-time Correction of Motion and Imager Instability Artifacts during 3D γ-Aminobutyric Acid-edited MR Spectroscopic Imaging.

Authors:  Eva Heckova; Michal Považan; Bernhard Strasser; Patrik Krumpolec; Petra Hnilicová; Gilbert J Hangel; Philipp A Moser; Ovidiu C Andronesi; Andre J van der Kouwe; Peter Valkovic; Barbara Ukropcova; Siegfried Trattnig; Wolfgang Bogner
Journal:  Radiology       Date:  2017-09-28       Impact factor: 11.105

Review 4.  The trouble with quality filtering based on relative Cramér-Rao lower bounds.

Authors:  Roland Kreis
Journal:  Magn Reson Med       Date:  2015-03-06       Impact factor: 4.668

5.  Advanced single voxel 1 H magnetic resonance spectroscopy techniques in humans: Experts' consensus recommendations.

Authors:  Gülin Öz; Dinesh K Deelchand; Jannie P Wijnen; Vladimír Mlynárik; Lijing Xin; Ralf Mekle; Ralph Noeske; Tom W J Scheenen; Ivan Tkáč
Journal:  NMR Biomed       Date:  2020-01-10       Impact factor: 4.044

6.  Applications of multi-nuclear magnetic resonance spectroscopy at 7T.

Authors:  Mary C Stephenson; Frances Gunner; Antonio Napolitano; Paul L Greenhaff; Ian A Macdonald; Nadeem Saeed; William Vennart; Susan T Francis; Peter G Morris
Journal:  World J Radiol       Date:  2011-04-28

7.  Single-voxel (1)H spectroscopy in the human hippocampus at 3 T using the LASER sequence: characterization of neurochemical profile and reproducibility.

Authors:  Najib Allaïli; Romain Valabrègue; Edward J Auerbach; Vincent Guillemot; Lydia Yahia-Cherif; Eric Bardinet; Maritza Jabourian; Philippe Fossati; Stéphane Lehéricy; Małgorzata Marjańska
Journal:  NMR Biomed       Date:  2015-08-18       Impact factor: 4.044

8.  Comparison of Multivendor Single-Voxel MR Spectroscopy Data Acquired in Healthy Brain at 26 Sites.

Authors:  Michal Považan; Mark Mikkelsen; Adam Berrington; Pallab K Bhattacharyya; Maiken K Brix; Pieter F Buur; Kim M Cecil; Kimberly L Chan; David Y T Chen; Alexander R Craven; Koen Cuypers; Michael Dacko; Niall W Duncan; Ulrike Dydak; David A Edmondson; Gabriele Ende; Lars Ersland; Megan A Forbes; Fei Gao; Ian Greenhouse; Ashley D Harris; Naying He; Stefanie Heba; Nigel Hoggard; Tun-Wei Hsu; Jacobus F A Jansen; Alayar Kangarlu; Thomas Lange; R Marc Lebel; Yan Li; Chien-Yuan E Lin; Jy-Kang Liou; Jiing-Feng Lirng; Feng Liu; Joanna R Long; Ruoyun Ma; Celine Maes; Marta Moreno-Ortega; Scott O Murray; Sean Noah; Ralph Noeske; Michael D Noseworthy; Georg Oeltzschner; Eric C Porges; James J Prisciandaro; Nicolaas A J Puts; Timothy P L Roberts; Markus Sack; Napapon Sailasuta; Muhammad G Saleh; Michael-Paul Schallmo; Nicholas Simard; Diederick Stoffers; Stephan P Swinnen; Martin Tegenthoff; Peter Truong; Guangbin Wang; Iain D Wilkinson; Hans-Jörg Wittsack; Adam J Woods; Hongmin Xu; Fuhua Yan; Chencheng Zhang; Vadim Zipunnikov; Helge J Zöllner; Richard A E Edden; Peter B Barker
Journal:  Radiology       Date:  2020-02-11       Impact factor: 11.105

9.  Test-retest reproducibility of neurochemical profiles with short-echo, single-voxel MR spectroscopy at 3T and 7T.

Authors:  Melissa Terpstra; Ian Cheong; Tianmeng Lyu; Dinesh K Deelchand; Uzay E Emir; Petr Bednařík; Lynn E Eberly; Gülin Öz
Journal:  Magn Reson Med       Date:  2015-10-26       Impact factor: 4.668

10.  Detection of Glutamate Alterations in the Human Brain Using 1H-MRS: Comparison of STEAM and sLASER at 7 T.

Authors:  Anouk Marsman; Vincent O Boer; Peter R Luijten; Hilleke E Hulshoff Pol; Dennis W J Klomp; René C W Mandl
Journal:  Front Psychiatry       Date:  2017-04-21       Impact factor: 4.157

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.