Literature DB >> 28951027

Fatigue Resistance of Nickel-titanium Instruments Exposed to High-concentration Hypochlorite.

Xiangya Huang1, Ya Shen2, Xi Wei3, Markus Haapasalo4.   

Abstract

INTRODUCTION: The purpose of this study was to introduce a new fatigue test model that simulates the clinical situation for evaluating the corrosion effect of 5.25% sodium hypochlorite (NaOCl) on nickel-titanium (NiTi) files and to evaluate the effect of 3 different temperatures (22°C, 37°C, and 60°C) on the cyclic fatigue of these files.
METHODS: Three NiTi files (size 25/.04), K3 (SybronEndo, Orange, CA), K3XF (SybronEndo), and Vortex (Dentsply Tulsa Dental Specialties, Tulsa, OK), were subjected to cyclic fatigue tests inside a novel artificial ceramic canal with a curvature of 60° and a 5-mm radius. A 19-mm-long file segment from the tip was introduced into the canal and immersed in water or 5.25% NaOCl at 3 different temperatures, and the number of revolutions to fracture (Nf) was recorded. The fracture surface of all fragments was examined by a scanning electron microscope. Data were analyzed using univariate analysis of variance with the significance level at 0.05.
RESULTS: The Nf of Vortex files was the highest followed by K3XF and K3 (P < .05) at all conditions. The Nf of all files was highest at 22°C and lowest at 60°C (P < .05). However, no difference in Nf was detected in Vortex files between 22°C and 37°C. The Nf of all files in 5.25% NaOCl was shorter than that in water although there was no statistically significant difference. No pitting or crevice corrosion was observed on the fracture surface.
CONCLUSIONS: NaOCl, 5.25%, does not significantly affect the fatigue behavior of NiTi files. The fatigue resistance should be tested under specific temperature conditions. The austenite finish temperature of a file is important in determining the fracture risk at body temperature.
Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Ceramic canal; corrosion; fatigue resistance; nickel-titanium instrument; sodium hypochlorite; temperature

Mesh:

Substances:

Year:  2017        PMID: 28951027     DOI: 10.1016/j.joen.2017.06.033

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  7 in total

1.  Comparison of the cyclic fatigue resistance of VDW.ROTATE, TruNatomy, 2Shape, and HyFlex CM nickel-titanium rotary files at body temperature.

Authors:  Mustafa Gündoğar; Gülşah Uslu; Taha Özyürek; Gianluca Plotino
Journal:  Restor Dent Endod       Date:  2020-06-22

2.  Effect of NaOCl and EDTA irrigating solutions on the cyclic fatigue resistance of EdgeTaper Platinum instruments.

Authors:  Hussam Alfawaz; Abdullah Alqedairi; Maha Alhamdan; Najla Alkhzim; Shatha Alfarraj; Ahmed Jamleh
Journal:  BMC Oral Health       Date:  2022-05-22       Impact factor: 3.747

3.  Effect of canal curvature location on the cyclic fatigue resistance of reciprocating files.

Authors:  Tyler Sobotkiewicz; Xiangya Huang; Markus Haapasalo; Christophe Mobuchon; Ahmed Hieawy; Jinghao Hu; Huimin Zhou; Zhejun Wang; Ya Shen
Journal:  Clin Oral Investig       Date:  2020-06-02       Impact factor: 3.573

4.  Effect of immersion in sodium hypochlorite on the cyclic fatigue resistance of three rotary instruments.

Authors:  Daiane Nogueira; Carlos Eduardo Da Silveira Bueno; Augusto Shoji Kato; Alexandre Sigrist De Martin; Rina Andréa Pelegrine; Ana Grasiela Da Silva Limoeiro; Daniel Guimarães Pedro Rocha; Carlos Eduardo Fontana
Journal:  J Conserv Dent       Date:  2021-02-11

5.  Influence of Sodium Hypochlorite and Chlorhexidine on the Dynamic Cyclic Fatigue Resistance of XP Endo Shaper Instruments.

Authors:  Alexandra Aparecida Tanomaru; Ana Grasiela Limoeiro; Adriana de Jesus Soares; Elson Lopes Medeiros Junior; Gabriel Rocha Campos; Sílvia Kaoru Hamasaki; Wayne Martins Nascimento; Luiz Meton Horta; Paula Avelar da Silva Ribeiro Goulart; Viviane Rangel do Couto; Patrícia Bastos Alves; Verônica Magalhães; Danilo De Luca Campos; Marcos Frozoni
Journal:  Eur J Dent       Date:  2021-12-22

Review 6.  Effect of body temperature on the cyclic fatigue resistance of the nickel-titanium endodontic instruments: A systematic review and meta-analysis of in vitro studies.

Authors:  Selventhra Savitha; Sidhartha Sharma; Vijay Kumar; Amrita Chawla; Perumal Vanamail; Ajay Logani
Journal:  J Conserv Dent       Date:  2022-08-02

7.  Shot peening increases resistance to cyclic fatigue fracture of endodontic files.

Authors:  Javier Nino-Barrera; Jose Sanchez-Aleman; Manuel Acosta-Humanez; Luis Gamboa-Martinez; Carlos Cortes-Rodriguez
Journal:  Sci Rep       Date:  2021-06-21       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.