BACKGROUND: Although bovine serum albumin-glutaraldehyde glue (BioGlue®) has been successfully used as a hemostatic adjunct in aortic surgical procedures, there are reports that it may lead to anastomotic pseudoaneurysm formation. We seek to examine if the use of BioGlue is associated with a high incidence of anastomotic pseudoaneurysm formation following surgical repair of thoracic aortic disease.
METHODS: We reviewed the medical records and follow-up computed tomography (CT) scans of patients from 2001 to 2015 in whom BioGlue was used during surgical repair of thoracic aortic disease to detect postoperative anastomotic pseudoaneurysm formation.
RESULTS: A total of 233 patients with BioGlue use were identified. Mean age was 63.5±14.0 years (median 66; range 14-88; 25-75%, IQR 54-74 years) and 149 were male (63.9%). Surgical indication was thoracic aortic aneurysm in 169 (72.5%) patients, aortic dissection in 49 (21.0%), intramural hematoma in 9 (3.9%), penetrating aortic ulcer in 3 (1.3%) and other in 3 (1.3%). Emergency/urgent surgery was performed in 68 cases (29.2%). Operative mortality was 7.3% (17/233). Re-exploration for bleeding and neurologic deficits occurred in 24 (10.3%) and 21 (9.0%) patients respectively. All operative survivors were followed (100%, 216/216) and CT follow-up was available in 81.9% (177/216) for a mean duration of 2.4 years (median 0.6; 25-75% IQR 0.2-3.6 years). Anastomotic pseudoaneurysm was detected in 1 patient (0.6%) at 3 years postoperatively. This was an elderly female with extremely frail tissues who underwent a reoperative ascending and arch replacement for dissection.
CONCLUSIONS: The use of BioGlue in thoracic aortic surgery was not associated with excess incidence of anastomotic pseudoaneurysm formation following surgical repair of thoracic aortic disease. Its use need not be discouraged on this basis.

Entities:  

Keywords:  Aortic aneurysm; BioGlue®; anastomotic pseudoaneurysm; aortic dissection; bovine serum albumin glutaraldehyde; postoperative bleeding; surgical adhesives

Year:  2017        PMID: 28932555      PMCID: PMC5594166          DOI: 10.21037/jtd.2017.06.120

Source DB:  PubMed          Journal:  J Thorac Dis        ISSN: 2072-1439            Impact factor:   2.895


  27 in total

1.  Aortic root replacement with stentless porcine xenografts: early and late outcomes in 132 patients.

Authors:  Scott A LeMaire; Susan Y Green; Kapil Sharma; Catherine K Cheung; Aryan Sameri; Peter I Tsai; Gerald Adams; Joseph S Coselli
Journal:  Ann Thorac Surg       Date:  2009-02       Impact factor: 4.330

2.  Complications of Bioglue postsurgery for aortic dissections and aortic valve replacement.

Authors:  Adriana Luk; Tirone E David; Jagdish Butany
Journal:  J Clin Pathol       Date:  2012-08-07       Impact factor: 3.411

3.  Long-term results of neomedia sinus valsalva repair in 489 patients with type A aortic dissection.

Authors:  Bartosz Rylski; Joseph E Bavaria; Rita K Milewski; Prashanth Vallabhajosyula; William Moser; Emily Kremens; Alberto Pochettino; Wilson Y Szeto; Nimesh D Desai
Journal:  Ann Thorac Surg       Date:  2014-06-10       Impact factor: 4.330

4.  Role of bovine serum albumin-glutaraldehyde glue in the formation of anastomatic pseudoaneurysms.

Authors:  Joshua Weiner; Shannon Widman; Zygmunt Golek; Maryann Tranquilli; John A Elefteriades
Journal:  J Card Surg       Date:  2010-11-28       Impact factor: 1.620

5.  Acute type A dissection: conservative methods provide consistently low mortality.

Authors:  Stephen Westaby; Satoshi Saito; Takahiro Katsumata
Journal:  Ann Thorac Surg       Date:  2002-03       Impact factor: 4.330

6.  Use of BioGlue in aortic surgery: proper application techniques and results in 92 patients.

Authors:  John W Fehrenbacher; Harry Siderys
Journal:  Heart Surg Forum       Date:  2006       Impact factor: 0.676

7.  Advances in the treatment of acute type A dissection: an integrated approach.

Authors:  Joseph E Bavaria; Derek R Brinster; Robert C Gorman; Y Joseph Woo; Thomas Gleason; Alberto Pochettino
Journal:  Ann Thorac Surg       Date:  2002-11       Impact factor: 4.330

8.  Clinical experience with fibrin glue in cardiac surgery.

Authors:  G Köveker; E R de Vivie; K D Hellberg
Journal:  Thorac Cardiovasc Surg       Date:  1981-10       Impact factor: 1.827

9.  Application of biological glue in repair of intracardiac structural defects.

Authors:  Daniel Fink; James J Klein; Hyun Kang; M Arisan Ergin
Journal:  Ann Thorac Surg       Date:  2004-02       Impact factor: 4.330

10.  Fate of coronary ostial anastomoses after the modified Bentall procedure.

Authors:  Aldo D Milano; Stefano Pratali; Gianclaudio Mecozzi; Piero Boraschi; Giovanni Braccini; Enrico Magagnini; Uberto Bortolotti
Journal:  Ann Thorac Surg       Date:  2003-06       Impact factor: 4.330

View more
  2 in total

1.  Cytocompatibility and mechanical properties of surgical sealants for cardiovascular applications.

Authors:  Mark H Murdock; Jordan T Chang; Samuel K Luketich; Drake Pedersen; George S Hussey; Antonio D'Amore; Stephen F Badylak
Journal:  J Thorac Cardiovasc Surg       Date:  2018-09-01       Impact factor: 5.209

2.  BioGlue® is not associated with polypropylene suture breakage after aortic surgery.

Authors:  Davide Pacini; Giacomo Murana; David Hollinworth; William F Northrup; Stacy G Arnold; Roberto Di Bartolomeo
Journal:  Front Surg       Date:  2022-09-09
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.