Literature DB >> 14759427

Application of biological glue in repair of intracardiac structural defects.

Daniel Fink1, James J Klein, Hyun Kang, M Arisan Ergin.   

Abstract

BACKGROUND: BioGlue (Cryolife Inc, Kennesaw GA) was introduced as an alternative tissue sealant. Its most common application has been in repairs of acute dissections of the aorta. There is no reported experience with its use in the repair of intracardiac structural defects.
METHODS: In 5 patients BioGlue was used as an adjunct in repairs of complex intracardiac structural defects. It was used during patch repair of posterior mitral annular defects in 2 patients and aortic annular defect in 1 patient in the presence of active endocarditis. It was also used in 1 patient with a chronic atrioventricular groove pseudoaneurysm following mitral valve replacement, and in 1 patient during repair of a postinfarction posterior ventricular septal rupture.
RESULTS: There were no hospital or late deaths. Immediate intraoperative transesophageal echocardiography and late follow-up echocardiography documented complete and durable repair of all defects without recurrence. At follow-up all patients are in New York Heart Association class I-II, 6 to 29 months postoperatively. No patient has suffered late complications or exhibited signs of glue embolization.
CONCLUSIONS: BioGlue was found to be an effective adjuvant to the standard techniques used for the repair of intracardiac structural defects of various etiologies. Long-term follow-up is recommended to determine its long-term safety in this application.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 14759427     DOI: 10.1016/S0003-4975(03)01533-9

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  6 in total

1.  Does BioGlue contribute to anastomotic pseudoaneurysm after thoracic aortic surgery?

Authors:  Wei-Guo Ma; Bulat A Ziganshin; Chang-Fa Guo; Mohammad A Zafar; Richard S Sieller; Maryann Tranquilli; John A Elefteriades
Journal:  J Thorac Dis       Date:  2017-08       Impact factor: 2.895

2.  The Use of a Bioadhesive (BioGlue(®)) Secured Conchal Graft and Mandibular Distraction Osteogenesis to Correct Pediatric Facial Asymmetry as Result of Unilateral Temporomandibular Joint Ankylosis.

Authors:  Joseph Kamal Muhammad; Bader Abdulla Al Hashimi; Abu Bakr Al Mansoor; Iqbal Ali
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2013-01-18

3.  Biological glue application in repair of atrioventricular groove rupture: a case report.

Authors:  Ahmet Baris Durukan; Fatih Tanzer Serter; Hasan Alper Gurbuz; Murat Tavlasoglu; Halil Ibrahim Ucar; Cem Yorgancioglu
Journal:  J Tehran Heart Cent       Date:  2014-07-03

4.  BioGlue® is not associated with polypropylene suture breakage after aortic surgery.

Authors:  Davide Pacini; Giacomo Murana; David Hollinworth; William F Northrup; Stacy G Arnold; Roberto Di Bartolomeo
Journal:  Front Surg       Date:  2022-09-09

5.  Glue-assisted intrascleral fixation of posterior chamber intraocular lens.

Authors:  Priya Narang; Samir Narang
Journal:  Indian J Ophthalmol       Date:  2013-04       Impact factor: 1.848

6.  BioGlue® manifesting as a subaortic floating object seen during ventricular septal rupture surgery: a case report.

Authors:  Kenzaburo Sugimoto; Mamoru Kadosaki; Sho Nakata; Kei Aizawa; Koji Kawahito; Mamoru Takeuchi
Journal:  JA Clin Rep       Date:  2020-04-14
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.