Literature DB >> 19027564

Changes in corneal wavefront aberrations in microincision and small-incision cataract surgery.

NuXia Tong1, Ji C He, Fan Lu, QinMei Wang, Jia Qu, Yun-E Zhao.   

Abstract

PURPOSE: To study the effect of incision size on the optical quality of the anterior cornea by comparing the changes in corneal wavefront aberrations between microincision cataract surgery (MICS) and small-incision cataract surgery (SICS).
SETTING: Eye Hospital of Wenzhou Medical College, Wenzhou, Zhejiang, China.
METHODS: This prospective randomized clinical study included 36 eyes having MICS (1.5 mm) and 38 eyes having SICS (3.0 mm). Anterior corneal topography was measured preoperatively and 3 to 6 months postoperatively. The data were used to calculate anterior corneal Zernike aberrations (through the 6th order) for a 6.0 mm central area.
RESULTS: In the MICS group, 2 corneal Zernike aberrations (trefoil and tetrafoil) changed significantly from preoperatively to postoperatively (both P<.0001). In the SICS group, in addition to trefoil and tetrafoil, oblique astigmatism (P<.0001), secondary oblique astigmatism (P= .001), and vertical tetrafoil (P= .001) changed significantly. The SICS group had greater changes than the MICS group in oblique astigmatism (P= .0001), oblique trefoil (P= .0035), and vertical tetrafoil (P= .0023). The changes in the SICS group were significantly greater than in the MICS group in the total root mean square (RMS) (P= .007) and higher-order RMS (P= .023) of corneal wavefront aberrations.
CONCLUSIONS: Cataract surgery-related changes in corneal wavefront aberrations were dependent on incision size. The MICS technique had advantages over the SICS technique in minimizing the effect of the incision size on the optical quality of the cornea.

Entities:  

Mesh:

Year:  2008        PMID: 19027564     DOI: 10.1016/j.jcrs.2008.08.020

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  10 in total

Review 1.  [Incisions for biaxial and coaxial microincision cataract surgery].

Authors:  M Müller; T Kohnen
Journal:  Ophthalmologe       Date:  2010-02       Impact factor: 1.059

2.  [Intraocular lenses for microincisional cataract surgery].

Authors:  T Kohnen; O K Klaproth
Journal:  Ophthalmologe       Date:  2010-02       Impact factor: 1.059

3.  Optimal incision sites to reduce corneal aberration variations after small incision phacoemulsification cataract surgery.

Authors:  Ling Chu; Jiang-Yue Zhao; Jin-Song Zhang; Jie Meng; Ming-Wu Wang; Ya-Jing Yang; Jia-Ming Yu
Journal:  Int J Ophthalmol       Date:  2016-04-18       Impact factor: 1.779

4.  Changes in corneal aberrations after cataract surgery.

Authors:  Yuki Hidaka; Takefumi Yamaguchi; Megumi Saiki; Murat Dogru; Kazuo Tsubota; Kazuno Negishi
Journal:  Jpn J Ophthalmol       Date:  2016-03-02       Impact factor: 2.447

Review 5.  Different-sized incisions for phacoemulsification in age-related cataract.

Authors:  Chongfei Jin; Xinyi Chen; Andrew Law; Yunhee Kang; Xue Wang; Wen Xu; Ke Yao
Journal:  Cochrane Database Syst Rev       Date:  2017-09-20

6.  Spherical aberration reduction in nuclear cataracts.

Authors:  Jong-Hyuck Lee; Hun Gu Choo; Sun Woong Kim
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-03-17       Impact factor: 3.117

7.  A comparable study of clinical and optical outcomes after 1.8, 2.0 mm microcoaxial and 3.0 mm coaxial cataract surgery.

Authors:  Yi-Bo Yu; Ya-Nan Zhu; Wei Wang; Yi-Dong Zhang; Yin-Hui Yu; Ke Yao
Journal:  Int J Ophthalmol       Date:  2016-03-18       Impact factor: 1.779

8.  Corneal Optical Quality Following Sub 1.8 mm Micro-Incision Cataract Surgery vs. 2.2 mm Mini-Incision Coaxial Phacoemulsification.

Authors:  Jorge L Alió; Bassam Elkady; Dolores Ortiz
Journal:  Middle East Afr J Ophthalmol       Date:  2010-01

9.  One-year follow-up of changes in refraction and aberrations induced by corneal incision.

Authors:  Eloy A Villegas; Encarna Alcón; Elena Rubio; José María Marín; Pablo Artal
Journal:  PLoS One       Date:  2019-11-18       Impact factor: 3.240

10.  Corneal astigmatism change and wavefront aberration evaluation after cataract surgery: "Single" versus "paired opposite" clear corneal incisions.

Authors:  Hasan Razmjoo; Nima Koosha; Mohammad Hadi Vaezi; Behrooz Rahimi; Alireza Peyman
Journal:  Adv Biomed Res       Date:  2014-08-19
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.